Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "partial discharge" wg kryterium: Temat


Tytuł:
Analysis on Acoustic Disturbance Signals Expected During Partial Discharge Measurements in Power Transformers
Autorzy:
Kunicki, Michał
Powiązania:
https://bibliotekanauki.pl/articles/1953519.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
acoustic emission
partial discharge
insulation system
measurements
power transformers
Opis:
This paper presents comparative analysis of various acoustic signals expected during partial discharge (PD) measurements in operating power transformer. Main purpose of the paper is to yield relevant and reliable method to distinguish between various acoustic emission (AE) signals emitted by PD and other sources, with particular consideration of real-life results rather than laboratory simulations. Therefore, selected examples of real-life AE signals registered in seven different power transformers, under normal operation conditions, within few years are showed and analyzed. Five scenarios are investigated, which represent five types of AE sources: PD generated by artificial sources, and next four real-life sources (including PD in working transformer, oil flow, oil pumps and core). Several different signal processing methods are applied and compared in order to identify the PD signals. As a result, an energy patterns analysis based on the wavelet decomposition is found as the most reliable tool for identification of PD signals. The presented results may significantly support the process of interpretation of the PD measurement results, and may be used by field engineers as well as other researchers involved in PD analysis using AE method. Finally, observed properties also provide a solid basis for establishing or improving complete classification method based on the artificial intelligence algorithms.
Źródło:
Archives of Acoustics; 2020, 45, 4; 733-746
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low voltage winding insulation systems under the influence of high du/dt slew rate inverter voltage
Autorzy:
Pauli, Florian
Ruf, Andreas
Hameyer, Kay
Powiązania:
https://bibliotekanauki.pl/articles/140993.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
life time
partial discharge
SiC semiconductors
winding insulation system
Opis:
Variable speed and low voltage electrical drives are commonly operated by frequency converters. According to recent developments, there is a trend in the area of semi-conductors, that switching frequency and voltage slew rate will increase significantly. The aim of these semiconductors is to reduce the switching losses and to increase the switching frequency, which enables to reduce the size of passive components in the powerelectric circuit. This results in less material effort and lower cost, for the power electronic component. However, electric motors operated by high slew rate inverters show problems in the winding insulation, which have to be analyzed. Such problems are well known for high voltage machines. Due to the increasing slew rate, this problematic occurs in low voltage machines nowadays as well. Here, the influence of fast switching semiconductors on the winding insulation system is studied, using accelerated ageing tests with fast switching high-voltage generators.
Źródło:
Archives of Electrical Engineering; 2020, 69, 1; 187-202
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PIFA antenna for partial discharge detection in power transformers
Autorzy:
Szymczak, Cyprian
Powiązania:
https://bibliotekanauki.pl/articles/1849124.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
diagnostics of power transformers
reliability of power transformers
partial discharge detection
UHF method
PIFA antenna
Opis:
The article presents the process of designing and manufacturing a prototype antenna based on the PIFA (Planar Inverted F Antenna) technology for the detection of UHF signals from partial discharges occurring in the power transformer insulation system. The main objective of the simulation studies was to obtain a frequency band covering the range of radio frequencies emitted by partial discharges in oil-paper insulation (surface discharges) and to adjust the dimensions of the antenna for its installation in the inspection window of the power transformer. The proposed structure consists of a radiating element in the shape of a rectangular meandering line and an additional parasitic element in the form of a specially selected resistor connecting the reflector with the radiator. The design of the prototype antenna was tested during laboratory tests in a high-voltage laboratory using a model of a transformer tank in which partial discharges were generated. The results of the measurements showed that the developed antenna has a higher sensitivity of partial discharge detection than other popular antennas used in transformer diagnostics, i.e. the disk antenna and the Hilbert fractal antenna. Due to high sensitivity, compact and simple structure and low production costs, the proposed PIFA antenna may be an interesting alternative to the currently used commercial antennas (mainly disk antennas) in on-line monitoring systems for partial discharges of power transformers.
Źródło:
Metrology and Measurement Systems; 2021, 28, 2; 343-355
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of protrusions on the initiation of partial discharges in XLPE high voltage cables
Autorzy:
AlShaikh Saleh, Mohammad
Refaat, Shady S.
Olesz, Marek
Abu-Rub, Haitham
Guziński, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/2173562.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
FEA
finite elements analysis
protrusions
XLPE
water trees
partial discharge
void
space charge
stress enhancement factor
analiza elementów skończonych
kable XLPE
polietylen kablowy
polietylen sieciowany
wyładowanie niezupełne
ładunek przestrzenny
Opis:
This paper is focusing on 3D Finite Elements Analysis (FEA) based modelling of protrusions as defects or imperfections in the XLPE high voltage cable. This study is aiming to examine the impact protrusions have on the initiation of partial discharges. Spherical and ellipsoidal protrusions with different sizes at the conductor screen of the high voltage cable is an essential content of this paper. In addition, a spherical gas-filled void is placed inside and outside the protrusions, and a water tree produced from protrusions is under consideration. The partial discharge influence taking place at the protrusions and the stress enhancement factor is determined for all the variations mentioned to quantify the rise in the inception of partial discharges due to the protrusions.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 1; art. no. e136037
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of protrusions on the initiation of partial discharges in XLPE high voltage cables
Autorzy:
AlShaikh Saleh, Mohammad
Refaat, Shady S.
Olesz, Marek
Abu-Rub, Haitham
Guziński, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/2090691.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
FEA
finite elements analysis
protrusions
XLPE
water trees
partial discharge
void
space charge
stress enhancement factor
analiza elementów skończonych
kable XLPE
polietylen kablowy
polietylen sieciowany
wyładowanie niezupełne
ładunek przestrzenny
Opis:
This paper is focusing on 3D Finite Elements Analysis (FEA) based modelling of protrusions as defects or imperfections in the XLPE high voltage cable. This study is aiming to examine the impact protrusions have on the initiation of partial discharges. Spherical and ellipsoidal protrusions with different sizes at the conductor screen of the high voltage cable is an essential content of this paper. In addition, a spherical gas-filled void is placed inside and outside the protrusions, and a water tree produced from protrusions is under consideration. The partial discharge influence taking place at the protrusions and the stress enhancement factor is determined for all the variations mentioned to quantify the rise in the inception of partial discharges due to the protrusions.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 1; e136037, 1--9
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of conductive particle contaminationon the insulation system of rotating electrical machines with direct oil cooling
Autorzy:
Yang, Liguo
Pauli, Florian
Zhang, Shimin
Hambrecht, Fabian
Hameyer, Kay
Powiązania:
https://bibliotekanauki.pl/articles/2135735.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cooling
insulation system
particle contamination
partial discharge
surface resistance
Opis:
An integration of the electrical machine and the gearbox is attracting particular attention for the design of modern electric and hybrid drive trains, since it saves overall space and subsequently increases the power density. Another benefit of a high level of integration is that it enables a combined application of oils as both cooling fluid for the electrical machine and as lubrication fluid for the transmission system. In this way, the power density of the integrated drive train can be further increased. During the oil cycling, conductive contaminations may be introduced and subsequently have an influence on the function of the insulation system of the electrical machine. In the present work, the influences of the cooling oil and its conductive contaminations, conductive particles as well as their combination with humidity, on the electrical and dielectric properties of the insulation system are studied. The results show that by application of the cooling oil, the partial discharge inception voltage (PDIV) of the winding insulation increases significantly so that an electrical breakdown is prone to happen before a partial discharge (PD) occurs. With increasing particle contamination, the PDIV of the insulation system decreases significantly, while the capacitance increases. Besides, conductive particles and humidity decrease the surface resistance and surface breakdown voltage of the insulation papers significantly. The results indicate that the conductive particle contaminations can play an important role for the electrical degradation of the insulation system.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 789--804
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An extrinsic Fabry–Pérot interference fiber sensor for ultrasonic detection of partial discharge
Autorzy:
Zhang, Ximin
Qian, Sen
Liu, Huixin
Chen, Chuan
Deng, Chuanlu
Hu, Chengyong
Huang, Yi
Powiązania:
https://bibliotekanauki.pl/articles/27310090.pdf
Data publikacji:
2023
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
extrinsic Fabry-Pérot interference
fibre sensor
partial discharge
sensitivity
frequency
Opis:
An ultrasonic sensor based on extrinsic Fabry–Pérot interference (EFPI) has been designed and demonstrated to detect the ultrasonic wave signal. The sensitivity and natural frequency of fiber Fabry–Pérot (F-P) sensor with different structure parameter have been simulated by COMSOL. The simulation results illustrate that the sensitivity is up to 1.737 nm/kPa and the natural frequency is 2.1 MHz, when the silica diaphragm thickness is 2 μm, the radius is 90 μm, and the cavity length is 18 μm. The most suitable parameters have been selected and the F-P sensor has been fabricated. When the ultrasonic signals with the frequencies of 40 kHz and 1.2 MHz are respectively applied to the sensor, the frequencies detected by the EFPI ultrasonic sensor are 39 kHz and 1.21 MHz based on a partial discharge detection experiment for the designed demodulation system. The experimental results show that the sensor can accurately detect ultrasonic signals. As an excellent platform for ultrasonic signal sensing, this EFPI ultrasonic sensing system has great potential applications in partial discharge detection field.
Źródło:
Optica Applicata; 2023, 53, 2; 199--211
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parameters that influence the partial discharges occurrence in cavity defect within electrical cable insulation
Autorzy:
Elagoun, Abdelkader
Seghier, Tahar
Powiązania:
https://bibliotekanauki.pl/articles/2203643.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
electrical cable insulation
cavity defect
partial discharge
plasma model
parameters influencing PDs
kabel elektryczny
izolacja
wyładowania niezupełne
model plazmowy
Opis:
The electrical cable reliability is largely linked to the state of its insulation, which can be threatened by the partial discharges (PDs) activity. This phenomenon is localized in defects created within insulation during the manufacture process and the cable installation. The cavity defect is among the most known defects within the insulating material filled with different gases and having various forms. Under electrical stress, the PDs occur and lead with time to a cable failure. The PDs simulation in cavity defect within cable insulation has became an important tool for a complementary understanding of the experimental task. The plasma model has been considered in last decade as an alternative to describe physically and chemically the PDs mechanism versus the other models such as the capacitance, conductance model. Using plasma model our work aims to simulate the PDs in cavity defect within cable insulation by showing the parameters influence such as the type of gas contained in the cavity, the voltage magnitude and frequency imposed on the insulation on their occurrence through its occurrence mechanisms. This helps to assess the PDs severity on the insulation system to carry out its diagnosis and therefore to have an effective reliability of cable.
Źródło:
Diagnostyka; 2023, 24, 2; art. no. 202321
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies