Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Yüksel, H." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Radiation Damage Centers in Cholesteryl Heptanoate
Autorzy:
Sayin, U.
Can, C.
Türkkan, E.
Dereli, Ö.
Ozmen, A.
Yüksel, H.
Powiązania:
https://bibliotekanauki.pl/articles/1399506.pdf
Data publikacji:
2013-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
61.80.-x
Opis:
Cholesterol takes part significantly in many biological mechanisms and as important component for manufacture of bile acids, steroid hormones, and several fat-soluble vitamins. To determine magnetic properties of cholesteryl heptanoate $(C_{34}H_{58}O_2)$ which is an important cholesteryl ester in human life and new technology, the single crystals of cholesteryl heptanoate were grown by slow evaporation of concentrated ethyl acetate solution and the grown single crystals were irradiated at room temperature with $\text{}^{60}Co \gamma $ ray. The radical produced by gamma irradiation has been investigated in the range of temperatures 123-330 K for different orientations of the crystal in a magnetic field by EPR. Radiation damage center was attributed to radical $ĊH_α CH_{2β}$. The g factor and hyperfine coupling constants have slight dependence on temperature and evident dependence on the orientation of the magnetic field. Determined g factor and hyperfine coupling constants for the radical $ĊH_α CH_{2β}$ were found to be anisotropic with the average values $g_{av}=2.0036$, $(a_{CH_\alpha})_{av}=14.52 G, (a_{CH_{2\beta}})_{av}=25.78 G$.
Źródło:
Acta Physica Polonica A; 2013, 124, 1; 70-73
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
235U isotopic characterization of natural and enriched uranium materials by using multigroup analysis (MGA) method at a defined geometry using different absorbers and collimators
Autorzy:
Yücel, H.
Yeltepe, E.
Yüksel, A. Ö.
Dikmen, H.
Powiązania:
https://bibliotekanauki.pl/articles/146510.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
nuclear safeguards
enrichment measurements
uranium
multigroup analysis
enrichment meter principle
Opis:
Characterization of nuclear materials is an important topic within the context of nuclear safeguards, homeland security and nuclear forensics. This paper deals with the performance of multigroup gamma-ray analysis (MGA) method using the X- and γ-rays in the 80–130 keV region and enrichment meter principle (EMP) based on the analysis of 185.7 keV peak for a certain geometry using different absorbers and collimators. The results from MGA and those of EMP are compared. In particular, the effect of aluminum/lead absorbers and lead collimator on the enrichment determination of 235U in natural and low enriched samples is investigated in a given source- -detector geometry. The optimum diameter/height ratio for the Pb-collimator is found to be Dc/Hc = 1.4–1.6 in the chosen geometry. In order to simulate the container walls, ten different thicknesses of Al-absorbers of 141 to 840 mg·cm–2 and six different thicknesses of Pb-absorbers of 1120–7367 mg·cm–2 are interposed between sample and detector. The calibration coefficients (% enrichment/cps) are calculated for each geometry. The comparison of the MGA and EMP methods shows that the enrichment meter principle provides more accurate and precise results for 235U abundance than those of MGA method at the chosen geometrical conditions. The present results suggest that a two-step procedure should be used in analyses of uranium enrichment. Firstly MGA method can be applied in situ and then EMP method can be used at a defined geometry in laboratory.
Źródło:
Nukleonika; 2015, 60, No. 3, part 2; 615-620
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies