Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Polednik, A." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Particle concentrations in a church during different weather conditions – a case study
Autorzy:
Polednik, B.
Polednik, A.
Powiązania:
https://bibliotekanauki.pl/articles/124156.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
church microclimate
incense burning
mass attendant
particle exposure
weather
Opis:
The purpose of this study is to report particle number (PN) and particle mass (PM) concentration changes in the church during three 60-minute Masses held on a cloudy, sunny and rainy day. At each Mass with a similar number of participants the same number of candles was lit and incense was burned. The highest average PN1 and PM1 concentrations of submicrometer particles which respectively amounted to 23.9 pt/cm3 and 241.1 µg/m3 were obtained for the Mass held on a rainy day. During that Mass the maximum PN1 and PM1 concentrations (amounting to 59.4×103pt/cm3 and 632 µg/m3) were respectively about 15 and 39 times higher than the church background levels. The greatest number of submicrometer particles (about 18.5×109) was inhaled by an average participant of the Mass held on a sunny day and it was approximately 7 times higher than the number that would have been inhaled at the same time outdoors. The greatest mass of such particles (about 195.4 µg) was inhaled by an average participant of the Mass held on a rainy day and it was approximately 8 times higher than the mass of particles that would have been inhaled outdoors during the same time.
Źródło:
Journal of Ecological Engineering; 2016, 17, 5; 173-185
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air Quality in a Brewery Bottling Plant
Jakość powietrza w rozlewni piwa w browarze
Autorzy:
Połednik, B.
Dudzińska, M.
Czerwiński, J.
Polednik, A.
Powiązania:
https://bibliotekanauki.pl/articles/1818042.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
air quality
aerosols
bioaerosols
carbonyl compounds
bottling plant
jakość powietrza
aerozol
bioaerozol
związki karbonylowe
rozlewnia piwa
Opis:
Przedstawione wyniki badań dotyczą jakości powietrza w rozlewni piwa. W trakcie normalnej pracy rozlewni mierzone były stężenia masowe i koncentracje ilościowe cząstek aerozolowych, stężenia bakterii i grzybów oraz stężenia związków karbonylowych w powietrzu. Stężenia aerozoli określano w sposób ciągły metodami spektrometrii optycznej. Zanieczyszczenia biologiczne oznaczano metodą sedymentacyjną wykorzystując płytki Petriego z odpowiednimi pożywkami. Stężenia związków karbonylowych w powietrzu określano metodą pasywną używając dozymetrów Radiello. Przy oznaczaniu stężeń zanieczyszczeń biologicznych i związków karbonylowych wykonano odpowiednio dwie i trzy serie pomiarowe w dwóch miejscach rozlewni piwa. Pomimo zautomatyzowania procesu rozlewania piwa do butelek zaobserwowano okresowe znaczące wzrosty stężeń mierzonych zanieczyszczeń. Średnie stężenia masowe wszystkich mierzonych frakcji cząstek aerozolowych miały podobne wartości i wynosiły ok. 0,2 mg/3. Maksymalnie ok. 5-cio krotne wzrosty koncentracji masowych cząstek obserwowano w nieregularnych odstępach czasu. Największe koncentracje ilościowe zmierzono dla cząstek drobnych. Średnie koncentracje cząstek o wielkościach 0,3-0,5 µm i 0,5-1 µm miały odpowiednio wartości 847 i 93 cząstki/c3. W przypadku zanieczyszczeń biologicznych średnie stężenie bakterii w powietrzu w rozlewni piwa wynosiło 1441 JTK/3, a średnie stężenie grzybów 557 JTK/3. Wartości te są niższe niż proponowane dopuszczalne poziomy stężeń bakterii i grzybów w budynkach użyteczności publicznej. Średnie stężenia mierzonych związków karbonylowych również nie przekraczały wartości, które są dopuszczalnych w środowisku pracy. Oprócz formaldehydu, którego okresowe stężenia wzrastały do prawie 800 µg/3 stężenia innych związków były w zakresie akceptowalnym dla pomieszczeń przeznaczonych na pobyt ludzi. Nieco wyższe stężenia niektórych związków karbonylowych odnotowano w punkcie pomiarowym w pobliży myjni butelek. Przedstawione wyniki wskazują, że istnieje potencjalne zagrożenie dla zdrowia pracowników rozlewni piwa związane z okresowymi wzrostami stężeń mierzonych zanieczyszczeń.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 591-602
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Traffic-related particle emissions and exposure on an urban road
Emisja cząstek ze źródeł komunikacyjnych w mieście
Autorzy:
Połednik, B.
Piotrowicz, A.
Pawłowski, L.
Guz, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/205054.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
vehicle emissions
mobile monitoring
particle concentration
commuters
deposition dose
emisje motoryzacyjne
monitoring mobilny
stężenie cząstek
uczestnik ruchu drogowego
narażenie zdrowotne
dawka osadzająca
Opis:
Extensive aerosol particle concentrations are one of the factors contributing to poor air quality in cities. The aim of this study is to assess particle number and mass concentrations on a road in Lublin, Poland, in peak and off-peak traffic hours and its impact on the particle exposure for commuters and pedestrians. Mobile monitoring and fixed-site measurements on the sidewalk along the established 2.1 km long route were conducted with the use of Mobile Air Pollution Analytic Laboratory equipped, among other things, with instruments measuring the real-time number and mass concentrations of particles with size range from 10 nm to 32 μm. The highest average concentrations of ultrafine particle number PN0.1 (25.4 ±11×103 pt/cm3; mean ± standard deviation), total particle number PN (29.2 ±12×103 pt/cm3) as well as mass concentrations of PM2.5 (29.1 ±7.6 μg/m3) and PM10 (45.4 ±10.3 μg/m3) were obtained in peak traffic hours for the part of the route with the most intensive traffic. The average particle number concentrations for the entire route and the part of route with the most intensive traffic in peak times were found to be about 3 to 4 times higher than in off-peak times. The average particle mass concentrations were about twice as high. Furthermore, the average values of the examined particle number and mass concentrations were higher for the on-road measurements than for fixed-site measurements. Moreover, a greater percentage of ultrafine particles was observed during mobile monitoring than in the fixed-site measurement points. It was established that a greater number and mass of particles, irrespectively of their size range, is deposited in the respiratory tract of commuters and pedestrians in peak hours than in off-peak hours. In peak times the average particle doses received by commuters and pedestrians equaled 4.8 ±2.4×109 pt/h or 29.6 ±10.7 μg/h (PM10) and 4.2 ±2.3×109 pt/h or 29.6 ±8.6 μg/h (PM10), respectively. Additionally, in both peak and off-peak hours greater particle doses were determined in the considered part of the route with the most intensive traffic; however, in off-peak traffic times pedestrians are more exposed to traffic-related pollutants than commuters. Overall, the obtained results reflect the importance of traffic-related particle emission measurements for exposure evaluations and the need of taking the actions aimed at decreasing it.
Celem pracy było określenie stężenia liczbowego i masowego cząstek na wybranych ulicach Lublina w godzinach szczytu oraz poza szczytem, a także ocena narażenia kierowców i pieszych na ich oddziaływanie. W ramach badań przeprowadzono zarówno pomiary mobilne, jak i stacjonarne w określonych punktach pomiarowych na trasie o długości 2,1 km. Mierzono w czasie rzeczywistym między innymi stężenia liczbowe i masowe cząstek o rozmiarach w zakresie od 10 nm do 32 μm. Najwyższe średnie koncentracje ultradrobnych cząstek PN0.1 (25,4 ±11×103 #/cm3) oraz koncentracje całkowitej liczby cząstek PN (29,2 ±12×103 #/cm3), a także stężenia masowe PM2.5 (29,1 ±7,6 μg/m3) oraz PM10 (45,4 ±10,3 μg/m3) rejestrowano w godzinach szczytu na wydzielonym odcinku trasy o największej intensywności ruchu. Średnie koncentracje cząstek mierzone w godzinach szczytu dla całej trasy oraz dla wydzielonego odcinka były, w zależności od wielkości cząstek, ok. 3-4 razy większe w porównaniu do wyników pomiarów dla godzin pozaszczytowych. Z kolei średnie stężenia masowe cząstek były około dwa razy większe. Ponadto, większe średnie stężenia liczbowe i masowe cząstek odnotowano dla pomiarów mobilnych niż dla stacjonarnych. Wyznaczone dawki dotyczące liczby i masy cząstek deponowanych w drogach oddechowych kierowców w godzinach szczytu wynosiły odpowiednio 4,8 ±2,4×109 #/h i 29,6 ±10,7 μg/h (PM10). Zarówno dla godzin szczytu, jak i poza szczytem, większe dawki deponowanych cząstek uzyskano dla wydzielonego odcinka trasy o największej intensywności ruchu. Podsumowując, otrzymane wyniki wskazują na istotność pomiarów cząstek emitowanych ze źródeł komunikacyjnych, szczególnie w kontekście narażenia uczestników ruchu drogowego na te cząstki.
Źródło:
Archives of Environmental Protection; 2018, 44, 2; 83-93
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of air conditioning changes on the effective dose due to radon and its short-lived decay products
Autorzy:
Grządziel, A.
Kozak, K.
Mazur, J.
Połednik, B.
Dudzińska, M. R.
Bilska, I.
Powiązania:
https://bibliotekanauki.pl/articles/147303.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon
radon progeny
attached fraction of radon progeny
unattached fraction of radon progeny
dose conversion factor
Opis:
Most people spend the majority of their time in indoor environments where the level of harmful pollutants is often significantly higher than outdoors. Radon (222Rn) and its decay products are the example of radioactive pollutants. These radioisotopes are the main source of ionizing radiation in non-industrial buildings. The aim of the study was to determine the impact of air-conditioning system on radon and its progeny concentrations and thus on the effective dose. The measurements were carried out in the auditorium at the Environmental Engineering Faculty (Lublin University of Technology, Poland). Measurements of radon and its progeny (in attached and unattached fractions) as well as measurements of the following indoor air parameters were performed in two air-conditioning (AC) operation modes: AC ON and AC ON/OFF. The air supply rate and air recirculation were taken into consideration. The separation of radon progeny into attached and unattached fractions allowed for determining, respectively, the dose conversion factor (DCF) and the inhalation dose for teachers and students in the auditorium. A considerable increase of the mean radon progeny concentrations from 1.2 Bq/m3 to 5.0 Bq/m3 was observed in the AC ON/OFF mode compared to the AC ON mode. This also resulted in the increase of the inhalation dose from 0.005 mSv/y to 0.016 mSv/y (for 200 h/year). Furthermore, the change of the air recirculation rate from 0% to 80% resulted in a decrease of the mean radon concentration from 30 Bq/m3 to 12 Bq/m3 and the reduction of the mean radon progeny concentration from 1.4 Bq/m3 to 0.8 Bq/m3. This resulted in the reduction of the inhalation dose from 0.006 mSv/y to 0.003 mSv/y.
Źródło:
Nukleonika; 2016, 61, 3; 239-244
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies