Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Bru, P." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
High frequency metrology for intracardiac ablation: in-vivo results
Autorzy:
Rouane, A.
Bru, P.
Powiązania:
https://bibliotekanauki.pl/articles/221888.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
impedance matching
voltage measurement cell
current measurement cell
high frequency energy
Opis:
Cardiac Radiofrequency (RF) ablation is a commonly used clinical procedure for treating many cardiac arrhythmias. However, the efficacy of RF ablation may be limited by two factors: small ventricular lesions and impedance rise, leading to coagulum formation and desiccation of tissue. In this paper, a high frequency (HF) energy ablation system operating at 27.12 MHz based on an automated load matching system was developed. A HF energy matched probe associated to the automated impedance matching device ensures optimal transfer of the energy to the load. The aim of this study was to evaluate this energy for catheter ablation of the atrioventricular junction. In vivo studies were performed using 10 sheep to characterize the lesions created with the impedance matching system. No cardiac perforation was noted. No thrombus was observed at the catheter tip. Acute lesions ranged from 3 to 45 mm in diameter (mean šSD = 10.3š10) and from 1 to 15 mm in depth (6.7š3.9), exhibiting a close relationship between HF delivered power level and lesion size. Catheter ablation using HF current is feasible and appears effective in producing a stable AV block when applied at the AV junction and large myocardial lesions at ventricular sites.
Źródło:
Metrology and Measurement Systems; 2012, 19, 3; 603-610
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Recent developments for high intensity beams at GANIL
Autorzy:
Moscatello, M.
Anger, P.
Berthe, C.
Bertrand, P.
Bru, B.
David, L.
Di Giacomo, M.
Jamet, Ch.
Ozille, M.
Pellemoine, F.
Petit, E.
Savalle, A.
Vignet, J.-L.
Powiązania:
https://bibliotekanauki.pl/articles/146199.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
cyclotron
diagnostics
electrostatic deflectors
RF system
high intensity beam
Opis:
In December 2001, a 5 kW beam was accelerated for the first time at GANIL. This performance was achieved after the increase of SSC2 dee voltage from 170 kV to 200 kV. Moreover, several technical developments have been done, to improve the operation with high intensity beams, and a new electrostatic deflector is under construction in order to reduce losses and activation at the exit of SSC2. This paper presents an overview of these works and the main results on the last accelerated beams.
Źródło:
Nukleonika; 2003, 48,suppl.2; 155-158
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies