Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "time-to-digital converter" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Quantization error in time-to-digital converters
Autorzy:
Zaworski, Ł.
Chaberski, D.
Kowalski, M.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221677.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
time interval measurement
time-to-digital converter
quantization error
averaging
Opis:
Methods of time interval measurement can be divided into asynchronous and synchronous approaches. It is well known that in asynchronous methods of time-interval measurement, uncertainty can be reduced by using statistical averaging. The motivation of this paper is an investigation of averaging in time interval measurements, especially in a synchronous measurement. In this article, authors are considering the method of averaging to reduce the influence of quantization error on measurement uncertainty in synchronous time-interval measurement systems, when dispersion of results, caused by noise is present. A mathematical model of averaging, which is followed by the results of numerical simulations of averaging of measurement series is presented. The analysis of results leads to the conclusion that in particular conditions the influence of the quantization error on measurement uncertainty can be minimized by statistical averaging, similar to asynchronous measurements.
Źródło:
Metrology and Measurement Systems; 2012, 19, 1; 115-122
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasonic flow measurement with high resolution
Autorzy:
Grzelak, S.
Czoków, J.
Kowalski, M.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221448.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasonic flowmeter
time-to-digital converter
programmable logic device
time measurement
Opis:
The ultrasonic flowmeter which is described in this paper, measures the transit of time of an ultrasonic pulse. This device consists of two ultrasonic transducers and a high resolution time interval measurement module. An ultrasonic transducer emits a characteristic wave packet (transmit mode). When the transducer is in receive mode, a characteristic wave packet is formed and it is connected to the time interval measurement module inputs. The time interval measurement module allows registration of transit time differences of a few pulses in the packet. In practice, during a single measuring cycle a few time-stamps are registered. Moreover, the measurement process is also synchronous and, by applying the statistics, the time interval measurement uncertainty improves even in a single measurement. In this article, besides a detailed discussion on the principle of operation of the ultrasonic flowmeter implemented in the FPGA structure, also the test results are presented and discussed.
Źródło:
Metrology and Measurement Systems; 2014, 21, 2; 305-316
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High resolution time-interval measurement systems applied to flow measurement
Autorzy:
Grzelak, S.
Kowalski, M.
Czoków, J.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221586.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
FPGA
time-to-digital converter
multi-segment delay line
carry chain
Opis:
The designing process of high resolution time interval measurement systems creates many problems that need to be eliminated. The problems are: the latch error, the nonlinearity conversion, the different duty cycle coefficient of the clock signal, and the clock signal jitter. Factors listed above affect the result of measurement. The FPGA (Field Programmable Gate Array) structure also imposes some restrictions, especially when a tapped delay line is constructed. The article describes the high resolution time-to-digital converter, implemented in a FPGA structure, and the types of errors that appear there. The method of minimization and processing of data to reduce the influence of errors on the measurement is also described.
Źródło:
Metrology and Measurement Systems; 2014, 21, 1; 77-84
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of Interpolators Used for Time-Interval Measurement Systems Based on Multiple-Tapped Delay Line
Autorzy:
Chaberski, D.
Frankowski, R.
Gurski, M.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221043.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
time interval
multiple-tapped delay line
quantization-and-nonlinearity minimization
FPGA
time-to-digital converter
Opis:
The paper describes the construction, operation and test results of three most popular interpolators from a viewpoint of time-interval (TI) measurement systems consisting of many tapped-delay lines (TDLs) and registering pulses of a wide-range changeable intensity. The comparison criteria include the maximum intensity of registered time stamps (TSs), the dependency of interpolator characteristic on the registered TSs’ intensity, the need of using either two counters or a mutually-complementing pair counter-register for extending a measurement range, the need of calculating offsets between TDL inputs and the dependency of a resolution increase on the number of used TDL segments. This work also contains conclusions about a range of applications, usefulness and methods of employing each described TI interpolator. The presented experimental results bring new facts that can be used by the designers who implement precise time delays in the field-programmable gate arrays (FPGA).
Źródło:
Metrology and Measurement Systems; 2017, 24, 2; 401-412
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie układów FPGA w konstrukcji przepływomierzy ultradźwiękowych
Application of FPGA devices to ultrasonic flowmeter
Autorzy:
Zaworski, Ł.
Kowalski, M.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/156070.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przepływomierz ultradźwiękowy
przetwornik czas-cyfra
układ programowalny
pomiar czasu
ultrasonic flowmeter
time-to-digital converter
programmable logic device
time measurement
Opis:
Przepływomierze ultradźwiękowe mierzące różnicę czasu przelotu impulsu przez medium stanowią jedną z dwóch najbardziej rozpowszechnionych grup przepływomierzy. W artykule tym została przedstawiona konstrukcja systemu pomiaru odcinka czasu zaimplementowanego w strukturze programowalnej FPGA jak również metoda kalibracji i wyznaczenia rozdzielczości przetwornika czas/cyfra w trakcie pomiaru. Takie rozwiązanie zapewnia niewrażliwość układu na czynniki zewnętrzne (temperatura), oraz skrócenie czasu pomiaru, a tym samym redukcję poboru energii, co jest atutem przy zasilaniu bateryjnym.
The ultrasonic flowmeter market is the fastest-growing market in any flowmeter type, and transit-time flowmeters have the largest share in that market. One of the fundamental parts of a transit-time ultrasonic flowmeter is a time measurement circuit, often implemented in CMOS ASIC. This paper describes an application of a low-power FPGA device to the transit-time flowmeter time measurement circuit. The main problem discussed in this work is calibration of a delay line in TDC implemented in a FPGA device. The time- and resource-consuming code density testing is undesirable for mass production devices. In this paper a fast and simple method for calibration is proposed. The method is based on measurement of the clock period length [5] and analysis of the data; therefore, it does not require implementation of any additional circuits in the device. A resolution of TDC is estimated by (2), when I_T is the largest state of a decoder in measurement series, and T_0 is clock period. The method uncertainty is larger than that of the code density test, but the method requires virtually no resources and takes less time - under certain conditions the calibration can be performed simultaneously with the measurement. At the end the measurement results and the conclusions are presented.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 12, 12; 1511-1514
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies