Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Zhao, T.T." wg kryterium: Autor


Wyświetlanie 1-6 z 6
Tytuł:
A novel method to calculate the mechanical properties of cancer cells based on atomic force microscopy
Autorzy:
Zhang, T
Zhao, Y.
Tong, Z.
Guang, Y.
Powiązania:
https://bibliotekanauki.pl/articles/307289.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
właściwości mechaniczne
AFM
moduł Younga
cells’ mechanical properties
eliminating thermal drift
Young's modulus
differential Hertz’s model
Opis:
Purpose: Mechanical properties, as the inherent characteristics of cells, play a critical role in many essential physiological processes, including cell differentiation, migration, and growth. The mechanical properties of cells are one of the criteria that help to determine whether the tissue contains lesions at the single cell level, and it is very important for the early prevention and accurate diagnosis of diseases. Atomic force microscopy (AFM) makes it possible to measure the mechanical properties at single cell level in physiological state. This paper presents a novel method to calculate the mechanical properties of cancer cells more accurately through Atomic force microscopy. Methods: A new induced equation of Hertz’s model, called differential Hertz’s model, has been proposed to calculate the mechanical properties of cancer cells. Moreover, the substrate effect has also been effectively reduced through comparing the calculated mechanical properties of cell at different cell surface areas. Results: The results indicate that the method utilized to calculate the mechanical properties of cells can effectively eliminate the errors in calculation, caused by the thermal drift of AFM system and the substrate effect, and thus improve the calculation accuracy. Conclusion: The mechanical properties calculated by our method in this study are closer to the actual value. Thus, this method shows potential for use in establishing a standard library of Young’s modulus.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 19-24
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of colloidal montmorillonite particles on froth flotation of graphite, galena and fluorite
Autorzy:
Chen, T.
Zhao, Y.
Li, H.
Song, S.
Powiązania:
https://bibliotekanauki.pl/articles/110589.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
montmorillonite
graphite
galena
fluorite
slime coating
entrainment
Opis:
The effect of colloidal montmorillonite (MMT) on froth flotation of graphite, galena and fluorite was investigated in this work. The results showed that the presence of sufficient amount of colloidal MMT particles in the mineral slurry would be detrimental of flotation by reducing the recovery of minerals. This observation was attributed to slime coating of MMT on the coarse valuable mineral particles and entrainment of MMT particles in the froth product together with water in the triangle froth zones. The former would reduce the recovery of the valuable minerals because of hydrophilic MMT coating. The latter would decrease the concentrate grade. The degree of slime coating depended on slurry pH, while the degree of entrainment was closely related to water recovery. It was also found that slime coating was a dominant factor in mineral flotation in acidic pH regions in the presence of colloidal MMT particles.
Źródło:
Physicochemical Problems of Mineral Processing; 2017, 53, 2; 699-713
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical approach in recognition of selected features of rock structure from hybrid hydrocarbon reservoir samples based on microtomography
Autorzy:
Kaczmarek, Ł. D.
Zhao, Y.
Konietzky, H.
Wejrzanowski, T.
Maksimczuk, M.
Powiązania:
https://bibliotekanauki.pl/articles/178817.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
compression test
flow paths
porosity
sandstone
Opis:
The study employs numerical calculations in the characterization of reservoir sandstone samples based on high-resolution X-ray computed microtomography. The major goals were to determine porosity through pore size distribution, permeability characterization through pressure field, and structure impact on rock strength by simulation of a uniaxial compression test. Two Miocene samples were taken from well S-3, located in the eastern part of the Carpathian Foredeep. Due to the relation between sample size and image resolution, two X-ray irradiation series with two different sample sizes were performed. In the first approach, the voxel side was 27 µm and in the second it was up to 2 µm. Two samples from different depths have been studied here. Sample 1 has petrophysical features of conventional reservoir deposits, in contrast to sample 2. The approximate grain size of sample 1 is in the range 0.1–1.0 mm, whereas for sample 2 it is 0.01–0.1 mm with clear sedimentation lamination and heterogenic structure. The porosity, as determined by µCT, of sample 1 is twice (10.3%) that of sample 2 (5.3%). The equivalent diameter of a majority of pores is less than 0.027 mm and their pore size distribution is unimodal right-hand asymmetrical in the case of both samples. In relations to numerical permeability tests, the flow paths are in the few privileged directions where the pressure is uniformly decreasing. Nevertheless, there are visible connections in sample 1, as is confirmed by the homogenous distribution of particles in the pore space of the sample and demonstrated in the particle flow simulations. The estimated permeability of the first sample is approximately four times higher than that of the second one. The uniaxial compression test demonstrated the huge impact of even minimal heterogeneity of samples in terms of micropores: 4–5 times loss of strength compared to the undisturbed sample. The procedure presented shows the promising combination of microstructural analysis and numerical simulations. More specific calculations of lab tests with analysis of variable boundary conditions should be performed in the future.
Źródło:
Studia Geotechnica et Mechanica; 2017, 39, 1; 13-26
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Free chlorine loss during spraying of membraneless acidic electrolyzed water and its antimicrobial effect on airborne bacteria from poultry house
Autorzy:
Zhao, Y.
Xin, H.
Zhao, D.
Zheng, W.
Tian, W.
Ma, H.
Liu, K.
Hu, H.
Wang, T.
Soupir, M.
Powiązania:
https://bibliotekanauki.pl/articles/49243.pdf
Data publikacji:
2014
Wydawca:
Instytut Medycyny Wsi
Źródło:
Annals of Agricultural and Environmental Medicine; 2014, 21, 2
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Advanced Deformation Stages in Duplex Steel Investigated using Neutron and Synchrotron Radiation
Autorzy:
Gadalińska, E.
Baczmański, A.
Zhao, Y.
Le Joncour, L.
Wroński, S.
Panicaud, B.
Francois, M.
Braham, C.
Buslaps, T.
Powiązania:
https://bibliotekanauki.pl/articles/97937.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
two-phases materials
mechanical behaviour
diffraction methods
Opis:
The grain scale of materials is an area still open for investigations within the field of materials science. The most helpful tools to perform this type of research are diffraction methods. Within the research project presented in this paper two experiments were carried out employing two different types of radiation: neutron (ISIS) and synchrotron (ESRF). The aim of the work was to describe the stress state in the necking zone during the occurrence of a damage phenomenon (Fig. 1.) in separate phase and to check the level of the homogeneity. The supplemental tools were the finite elements method and self-consistent modeling – it testified, confirmed and completed our experimental results and allowed us to formulate the justifiable conclusions.
Źródło:
Fatigue of Aircraft Structures; 2016, 8; 80-91
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Airborne virus sampling-efficiencies of samplers and their detection limits for infectious bursal disease virus (IBDV)
Autorzy:
Zhao, Y.
Aarmink, A.J.A.
Wang, W.
Fabri, T.
Groot Koerkamp, P.W.
de Jong, M.C.M.
Powiązania:
https://bibliotekanauki.pl/articles/51080.pdf
Data publikacji:
2014
Wydawca:
Instytut Medycyny Wsi
Opis:
Introduction. The airborne transmission of infectious diseases in livestock production is increasingly receiving research attention. Reliable techniques of air sampling are crucial to underpin the findings of such studies. This study evaluated the physical and biological efficiencies and detection limits of four samplers (Andersen 6-stage impactor, all-glass impinger “AGI-30”, OMNI-3000 and MD8 with gelatin filter) for collecting aerosols of infectious bursal disease virus (IBDV). Materials and Method. IBDV aerosols mixed with a physical tracer (uranine) were generated in an isolator, and then collected by the bioaerosol samplers. Samplers’ physical and biological efficiencies were derived based on the tracer concentration and the virus/tracer ratio, respectively. Detection limits for the samplers were estimated with the obtained efficiency data. Results. Physical efficiencies of the AGI-30 (96%) and the MD8 (100%) were significantly higher than that of the OMNI-3000 (60%). Biological efficiency of the OMNI-3000 (23%) was significantly lower than 100% (P < 0.01), indicating inactivation of airborne virus during sampling. The AGI-30, the Andersen impactor and the MD8 did not significantly inactivate virus during sampling. The 2-min detection limits of the samplers on airborne IBDV were 4.1 log10 50% egg infective dose (EID50) m-3 for the Andersen impactor, 3.3 log10 EID50 m-3 for the AGI-30, 2.5 log10 EID50 m-3 for the OMNI-3000, and 2.9 log10 EID50 m-3 for the MD8. The mean half-life of IBDV aerosolized at 20 °C and 70% was 11.9 min. Conclusion. Efficiencies of different samplers vary. Despite its relatively low sampling efficiency, the OMNI-3000 is suitable for use in environments with low viral concentrations because its high flow rate gives a low detection limit. With the 4 samplers investigated, negative air samples cannot guarantee virus-free aerial environments, which means that transmission of infectious agents between farms may still occur even when no virus has been detected.
Źródło:
Annals of Agricultural and Environmental Medicine; 2014, 21, 3
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies