Tytuł:
Comparative studies of various methods of mounting the implant mandrel within the bone
Autorzy:
Zaczyk, M.
Jasińska-Choromańska, D.
Powiązania:
https://bibliotekanauki.pl/articles/385143.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
mounting of an implant mandrel within the osseous tissue
endoprosthesis
implant-bone contact
Opis:
The paper presents results of studies pertaining to evaluation of a quality (compressive strength of mounting the implant within the bone) of mounting the implant mandrel within the osseous tissue for various relevant techniques. The presented results are related to selected techniques of mounting the implant mandrel within a bone. The comparison has been carried out for cement-less mandrels with a smooth mandrel of the endoprosthesis, porous cementless endoprostheses as well as mandrels made of bioactive materials.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2012, 6, 3; 33-36
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar wybranych parametrów biomechanicznych w trakcie realizacji
Measurements of selected biomechanical parameters during experimental studies of an implant-bone connection
Autorzy:
Zaczyk, M.
Jasińska-Choromańska, D
Powiązania:
https://bibliotekanauki.pl/articles/153011.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary biomechaniczne
eksperymentalne badania połączenia implant-kość
jakość osadzenia implantu w tkance kostnej
biomechanical measurement
experimental tests implant-bone
Opis:
Praca przedstawia jedną z metod badania osadzenia implantu w tkance kostnej. Opisano metodykę badań, dzięki której możliwa jest ocena jakości osadzenia implantu w tkance kostnej. W badaniach eksperymentalnych nowo poznawanych zjawisk kluczowe staje się odpowiednie dobranie aparatury pomiarowej. Poprawny dobór przyrządów pomiarowych pozwala na jednoznaczny opis badanego zjawiska lub obiektu.
The paper presents one of the methods of testing an implant mounting within the osseous tissue. It describes a methodology of the studies, which makes it possible to evaluate quality of the implant mounting within the osseous tissue. In the case of experimental studies of new phenomena being just investigated, it is crucial to appropriately select the measurement equipment. A correct selection of the measuring instruments allows one to unequivocally describe the studied phenomenon or object. A specific character of biomechanical properties of bones makes it impossible to carry out experiments using universal measuring machines, what results in a necessity of building custom test stations as well as special measure-ment systems based on well-developed measurement applications. As far as the described method of testing is concerned, there can be distinguished the following three stages:- the first, including preparations of the objects for the studies,- the second, including carrying out of measurements using the objects that have been prepared beforehand,- the third, including analytical determination of numerical values of the studied parameters. At the first stage, a minimum of the sample should be prepared, using an osseous tissue taken from a closer shaft of a cow thigh bone. After a pretreatment of the bone, a fragment of the tested mandrel should be mounted within it. The test station for experimental studies of the mandrel mounting within the osseous tissue must ensure a possibility of a real-time recording of the related displacements and load forces. The experiment was repeated many times in order to minimize the scatter of the indications. Basing on the obtained results, mutual correlations of particular data were determined, e.g. displacements of the mandrel within the bone in relation to the applied load. The obtained results make it possible to specify what kind of dynamics of the load applying influences the osseous tissue reaction rate.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 6, 6; 575-578
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena dokładności wyników eksperymentalnego badania połączenia implant-kość
Result accuracy evaluation of experimental studies of an implant-bone connection
Autorzy:
Zaczyk, M.
Jasińska-Choromańska, D.
Kołodziej, D.
Powiązania:
https://bibliotekanauki.pl/articles/153013.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary biomechaniczne
eksperymentalne badania połączenia implant-kość
jakość osadzenia implantu w tkance kostnej
biomechanical measurement
experimental tests implant-bone
implant fixation quality in the bone
Opis:
Praca zawiera opis metodyki wyznaczenia niepewności dla pomiarów biomechanicznych realizowanych podczas badań eksperymentalnych osadzenia implantu w tkance kostnej. Przedstawiona procedura szacowania niepewności pozwoliła określić, które z etapów procesu pomiarowego eksperymentu miały znaczący wpływ na błędy wyników i z jaką ufnością można podchodzić do wartości liczbowych, opisujących badaną własność biomechaniczną.
The paper presents a methodology of determining uncertainty in biomechanical measurements realized during experimental studies of an implant mounting within an osseous tissue. The presented procedure of evaluating the uncertainty allows one to determine which of the stages of the measurement process of the experiment had a significant influence on the errors of the obtained results, and how much is a confidence level corresponding to the numerical values describing a studied biomechanical property. Values of biomechanical properties are usually obtained in an experimental way. A unification of the analysis of the studies is a decisive factor with respect to the reliability and usability of the results, as well as a possibility of comparing these values for a given property obtained in other experiment. Analysis of the sources of the measurement uncertainties with respect to the realized process of recording the given numeric values of the properties searched for, provided it has been carried out reliably, allows one to create a mathematical equation of the related process. Analysis of evaluating uncertainty related to the presented experiment proved that both the measurement equipment and the methodology of experimental studies were selected correctly, and the most significant influence on the resultant errors had its source in biomechanical properties of the materials used for building the object of experiments. It was impossible to eliminate error sources related to the applied osseous material, since each bone used for building a sample originated from a different specimen, having at the same time its own individual characteristics.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 6, 6; 579-582
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy projektowania napędów do układu wspomagania ruchu osób niepełnosprawnych
Various aspects of design of the drive systems for orthotic robots
Autorzy:
Jasińska-Choromańska, D.
Credo, W.
Szykiedans, K.
Rzeszotek, Ł.
Semeniuk, J.
Zaczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/98735.pdf
Data publikacji:
2012
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
osoby niepełnosprawne
niedowład
kończyna dolna
wspomaganie ruchu
układ napędowy
robot ortotyczny
disabled persons
paresis
lower limb
motion support
drive system
orthotic robot
Opis:
Celem projektu było opracowanie i zbudowanie oryginalnych technicznych modeli napędów do zastosowania w Systemie Pionizacji i Wspomagania Ruchu (SPiWR).System ten przeznaczony jest dla osób z niedowładem kończyn dolnych, zgodnie z najnowszymi tendencjami występującymi w dziedzinie bioniki[8,9]. W proponowanym rozwiązaniu osoba niepełnosprawna porusza się dzięki zastosowaniu mechanicznego układu do którego mocowane są kończyny dolne, zastępującego ich funkcje poprzez wymuszony ruch odtwarzający w znacznym zakresie naturalny ruch kończyn dolnych [2,3,4]. W artykule przedstawiono problematykę doboru układów napędowych systemu.
Źródło:
Aktualne Problemy Biomechaniki; 2012, 6; 43-50
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechatronic system for verticalization and aiding the motion of the disabled
Autorzy:
Jasińska-Choromańska, D.
Szykiedans, K.
Wierciak, J.
Kołodziej, D.
Zaczyk, M.
Bagiński, K.
Bojarski, M.
Kabziński, B.
Powiązania:
https://bibliotekanauki.pl/articles/202042.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
orthotic robots
aiding the human motion
mechatronic systems
Opis:
Mechatronics is nowadays a dominating concept in design of various kinds of systems and technical devices. High speeds of data processing by control units of mechatronic systems, as well as high dynamics of their actuators allow the systems to be applied in wider fields. This refers to the medicine as well, especially while making attempts to replace lost human motor abilities by means of robots aiding the man. These devices can be divided into three groups: exoskeletons designed to strengthen the natural force of human muscles, orthotic robots that restore lost or weakened functions of human limbs, and prosthetic robots replacing an amputated limb. The first and the third group are known quite well, whereas the orthotic robots are at an initial phase of their development. The authors have worked on a device for aiding the motion of disabled people suffering from paresis of the lower limbs. The paper presents a concept and a structure of the system that has been created, comparing it with similar devices that have already existed. There are indicated some connections and areas where the subunits merge, as well as the rules of their working with the user.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 2; 419-431
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies