Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Yi, R." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Influence of the number of turns on the performance of permanent magnet synchronous motor
Autorzy:
Qiu, H.
Zhang, Y.
Yang, C.
Yi, R.
Powiązania:
https://bibliotekanauki.pl/articles/200007.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
eddy currents density
losses
PMSM
number of turns
temperature field
Opis:
The current passed by the stator coil of the permanent magnet synchronous motor (PMSM) provides rotating magnetic field, and the number of turns will directly affect the performance of PMSM. In order to analyze its influence on the PMSM performance, a 3 kW, 1500 r/min PMSM is taken as an example, and the 2D transient electromagnetic field model is established. The correctness of the model is verified by comparing the experimental data and calculated data. Firstly, the finite element method (FEM) is used to calculate the electromagnetic field of the PMSM. The performance parameters of the PMSM are obtained. On this basis, the influence of the number of turns on PMSM performance is quantitatively analyzed, including current, no-load back electromotive force (EMF), overload capacity and torque. In addition, the influence of the number of turns on eddy current loss is further studied, and its variation rule is obtained, and the variation mechanism of eddy current loss is revealed. Finally, the temperature field of the PMSM is analyzed by the coupling method of electromagnetic field and temperature field, and the temperature rise law of PMSM is obtained. The analysis of this paper provides reference and practical value for the optimization design of PMSM.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 3; 429-436
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of different rotor magnetic circuit structure on the performance of permanent magnet synchronous motor
Autorzy:
Qiu, H.
Yu, W.
YANG, C.
Yi, R.
Powiązania:
https://bibliotekanauki.pl/articles/141061.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
air gap flux density
cogging torque
magnetic circuit structure
overload capacity
permanent magnet synchronous motor
Opis:
In order to compare the performance difference of the permanent magnet synchronous motors (PMSM) with different rotor structure, two kinds of rotor magnetic circuit structure with surface-mounted radial excitation and tangential excitation are designed respectively. By comparing and analyzing the results, the difference of the motor performance was determined. Firstly, based on the finite element method (FEM), the motor electromagnetic field performance was studied, and the magnetic field distribution of the different magnetic circuit structure was obtained. The influence mechanism of the different magnetic circuit structure on the air gap flux density was obtained by using the Fourier theory. Secondly, the cogging torque, output torque and overload capacity of the PMSM with different rotor structure were studied. The effect mechanism of the different rotor structure on the motor output property difference was obtained. The motor prototype with two kinds of rotor structure was manufactured, and the experimental study was carried out. By comparing the experimental data and simulation data, the correctness of the research is verified. This paper lays a foundation for the research on the performance of the PMSM with different magnetic circuit structure.
Źródło:
Archives of Electrical Engineering; 2017, 66, 3; 583-594
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Eddy current density asymmetric distribution of damper bars in bulb tubular turbine generator
Autorzy:
Qiu, H.
Fan, X.
Yi, R.
Feng, J.
Wu, J.
YANG, C.
ZHAO, H.
Powiązania:
https://bibliotekanauki.pl/articles/140467.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
damper bars
bulb tubular turbine generator
electromagnetic field
eddy current
Opis:
The major reasons that cause the damage of damper bars in the leeward side are found in this paper. It provides a route for the structure optimization design of a hydro generator. Firstly, capacity of a 24 MW bulb tubular turbine generator is taken as an example in this paper. The transient electromagnetic field model is established, and the correctness of the model is verified by the comparison of experimental results and simulation data. Secondly, when the generator is operated at rated condition, the eddy current density distributions of damper bars are studied. And the asymmetric phenomenon of the eddy current density on damper bars is discovered. The change laws of the eddy currents in damper bars are determined through further analysis. Thirdly, through the study of eddy current distributions under different conditions, it is confirmed that the stator slots and armature reaction are the main factors to affect the asymmetric distribution of the eddy current in damper bars. Finally, the studies of the magnetic density distribution and theoretical analysis revealed the asymmetric distribution mechanism of eddy current density.
Źródło:
Archives of Electrical Engineering; 2017, 66, 3; 571-581
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies