Operational problems of constructed wetland for landfill leachate treatment: case study
Autorzy:
Obarska-Pempkowiak, H.
Gajewska, M.
Wojciechowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/125011.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
treatment wetland
landfill leachate
clogging
Opis:
The present paper discusses the quality fluctuations of leachate from municipal landfill in Gdansk (Poland) over the last 5 years and the evaluation of a wetland system designed for treatment of the leachate. The research has been conducted during a 5-year period. The constructed wetland for leachate treatment was built in 2001; it consists of 2 horizontal subsurface flow reed beds, working in parallel. In the period 2005–2006 it underwent modernization due to unsatisfactory treatment results caused by bed clogging. After the modernization the treatment effectiveness is satisfactory. The effluent from bed I met Polish outflow standards, while in the effluent from bed II COD, total N and TSS exceeded the required concentrations. In spite of this, pretreatment of leachate (iron removal) should be quickly introduced to protect the system against the reoccurrence of clogging problems.
Źródło:
Journal of Ecological Engineering; 2013, 14, 3; 53-58
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of wastewater treatment in single-family constructed wetlands in Kaszuby Lake District
Skuteczność oczyszczania ścieków bytowych w przydomowych oczyszczalniach hydrofitowych na Pojezierzu Kaszubskim
Autorzy:
Obarska-Pempkowiak, H.
Gajewska, M.
Wojciechowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/1818796.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
skuteczność oczyszczania
przydomowe oczyszczalnie
pojezierze kaszubskie
Opis:
W pracy zaprezentowano wyniki badań trzech różnych konfiguracji oczyszczalni hydrofitowych stosowanych do oczyszczania ścieków bytowych z indywidualnych gospodarstw domowych. Wykazano, m.in., że zastosowanie oczyszczalni hydrofitowych jest zrównoważonym i stabilnym rozwiązaniem problemu gospodarowania ściekami na terenach o rozproszonej zabudowie. Oczyszczalnie przydomowe w Polsce otrzymują wyższe stężenia zanieczyszczeń niż odpowiednie oczyszczalnie w Europie czy USA, po mimo to analizowane obiekty zapewniały skuteczne usuwanie substancji organicznej: BZT5 do 92,0% i substancji biogennych: Nog do 77,0% i Pog do 66,0%. Konfiguracja II składająca się z dwóch charakteryzowała się najwyższą skutecznością usuwania zanieczyszczeń i w konsekwencji zapewniała najniższe stężenia zanieczyszczeń w oczyszczonych ściekach.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 1; 81-95
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operational problems of constructed wetland for landfill leachate treatment: case study
Problemy z eksploatacją systemów hydrofitowych dooczyszczania odcieków ze składowiska: studium przypadku
Autorzy:
Obarska-Pempkowiak, H.
Gajewska, M.
Wojciechowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/401274.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
system hydrofitowy
odciek ze składowiska
zatykanie się
treatment wetland
landfill leachate
clogging
Opis:
In the paper the quality fluctuations of leachate from municipal landfill in Gdansk (Poland) over the last 5 years and evaluation of a wetland system designed for treatment of the leachate are discussed. The research has been conducted during the 5 years period. The constructed wetland for leachate treatment, consisting of 2 horizontal subsurface flow reed beds, working in parallel was built in 2001. In the period 2005-06 it underwent modernization due to unsatisfactory treatment results caused by clogging of the beds. The treatment effectiveness after modernization is satisfactory. The effluent from bed I met Polish outflow standards, while in the effluent from bed II COD, total N and TSS exceeded the required concentrations. In spite of this, pre-treatment of leachate (iron removal) should be quickly introduced to protect the system against the repetition of clogging problems.
Opisane w artykule badania prowadzono w okresie pięciu lat. System hydrofitowy zbudowany w 2001 roku do oczyszczania odcieków ze składowiska składa się z dwóch poziomych złóż o przepływie podpowierzchniowym, w układzie równoległym. W 2005-2006 roku wykonano modernizację układu ze względu na problem z zatykaniem się złóż. Efektywność oczyszczania po modernizacji jest zadowalająca, odpływ ze złoża I spełnia polskie normy, natomiast w przypadku złoża II zaobserwowano przekroczenia ChZT i zawiesiny ogólnej. W celu uniknięcia zatykania się złóż należy zastosować wstępne oczyszczanie odcieków.
Źródło:
Inżynieria Ekologiczna; 2011, 25; 202-210
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Systemy hydrofitowe do oczyszczania spływów powierzchniowych w rejonie Zatoki Gdańskiej
Constructed wetland systems for serial runoff treatment in the gulf of Gdansk Region
Autorzy:
Obarska-Pempkowiak, H.
Gajewska, M.
Wojciechowska, E.
Stosik, M.
Powiązania:
https://bibliotekanauki.pl/articles/1819603.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
system hydrofitowy
Zatoka Gdańska
jakość wód
związki azotu
hydrofitowy system
Gulf of Gdansk
water quality
nitrogen compounds
Opis:
W artykule przywołano przykłady udanych wdrożeń obiektów hydrofitowych oczyszczania spływów obszarowych na terenie aglomeracji trójmiejskiej. Zespół obiektów hydrofitowych wybudowany w ZOO w Oliwie wykazał szczególnie wysoką skuteczność usuwania związków azotu. Obiekt hydrofitowy na Potoku Swelina spowodował znaczną poprawę jakości wód Potoku, a co za tym idzie i czystości kąpieliska w rejonie Kamiennego Potoku w Sopocie. Podjęte działania przyczyniły się do znacznej poprawy jakości wód Zatoki Gdańskiej w rejonach kąpielisk w Jelitkowie i Kamiennym Potoku.
In the article the examples of successful application of CW systems for treatment of aerial runoff at the Threecity agglomeration have been presented. The CW system at the ZOO in Oliwa was particularly effective in nitrogen removal. The CW system at Swelina Stream contributed to the significant improvement of the stream waters quality, resulting in the improvement of the quality of the bathing place located near its outflow to the Gulf of Gdańsk.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 173-185
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ technologii oczyszczania ścieków na spektrum rozmiarów cząstek w odpływie
Influence of wastewater treatment technology on particle size distribution in the effluent
Autorzy:
Gajewska, M.
Stosik, M.
Wojciechowska, E.
Obarska-Pempkowiak, H.
Powiązania:
https://bibliotekanauki.pl/articles/1819077.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
rozmiar cząstek
oczyszczanie ścieków
sewage
wastewater
Opis:
Suspended solids in water and wastewater usually carry quite a large load of pollutants (organic substances, nutrients, heavy metals, etc.) adsorbed on the particles surface. Particles of different sizes carry different types and quantities of pollutants. Therefore, particle size distribution is of importance in waster and wastewater treatment. In the article the influence of different treatment technologies on particle size distribution in the effluent was assessed. The analyses covered the effluents from two municipal wastewater treatment plants, drainage water, clean stormwater, oil-contaminated water and industrial sewage treated at the oil refinery and the water of a stream contaminated with stormwater run-off, treated in a constructed wetland. The equivalent diameters of particles were similar for all analyzed types of wastewater, however the share of different particle sizes in the total volume was different.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 2; 1191-1206
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sewage gardens – constructed wetlands for single family households
Autorzy:
Obarska-Pempkowiak, H.
Gajewska, M.
Wojciechowska, E.
Kołecka, K.
Powiązania:
https://bibliotekanauki.pl/articles/208217.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
przydomowa oczyszczalnia hydrofitowa
przydomowe oczyszczalnie
oczyszczanie hydrofitowe
roślinne oczyszczalnie ścieków
domy jednorodzinne
oczyszczanie ścieków
household sewage treatment wetland
household sewage
wetland treatment
treatment wetland (TWs)
wastewater treatment plant
single family
wastewater treatment
Opis:
During the last 30 years the increase of interest in low-cost decentralized and small wastewater treatment plants (WWTP) is observed in Europe. For this purpose, sand filters, stabilization ponds, mini reactors with activated sludge, trickling filters and treatment wetlands are used. Among the listed facilities, treatment wetlands (TWs) offer effective and reliable treatment efficiency, being at the same time low-cost and simple in operation. This is a sustainable treatment technology which does not generate secondary sewage sludge. In the paper, design concept and performance of nine TWs constructed in 2009 for single-family households in Kashubian Lake District is discussed. The treatment efficiency of three different TW configurations is compared. The findings of the study provide a basis for future design and implementation of TWs in agricultural areas.
Źródło:
Environment Protection Engineering; 2015, 41, 4; 71-82
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Eco-innovative Technologies of Nutrients Removal in Wastewater – Case Study BARITECH Project
Zastosowanie innowacyjnych technologii do usuwania związków biogennych ze ścieków – studium przypadku (BARITECH)
Autorzy:
Kasprzyk, M.
Pierzgalski, K.
Wojciechowska, E.
Obarska-Pempkowiak, H.
Gajewska, M.
Powiązania:
https://bibliotekanauki.pl/articles/1813856.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
nitrogen removal
phosphorus removal
reject water
constructed wetlands
usuwanie azotu
usuwanie fosforu
odcieki
oczyszczalnie hydrofitowe
Opis:
Eco-innovative technologies in wastewater treatment should provide not only stringent standards for the quality of treated wastewater but also ensure maximum recovery of energy and raw materials from wastewater. One of the ways to improve the removal efficiency of nitrogen and phosphorus compounds in existing conventional wastewater treatment plants is pretreatment of reject water generated during the mechanical dewatering of the digested sewage sludge. The aim of this research was to select the technological parameters of processes to ensure effective removal of nutrient elements (N, P) from RW treated in a SBR reactor in the nitritation/anammox process. The study was divided into two stages. The first stage was carried out to optimize nitrogen compounds removal in the effluent from ANAMMOX process used to treat reject water after centrifugation. The installation consists of single vertical subsurface flow (VSSF) beds located in stainless steel containers working parallel marked as BED control “0”, “I”, “II”. Samples have been taken for analysis to determine the changes of NH4-N, NO3-N and NO2-N in the effluent of each filter. In bed “0” the removal of nitrogen compounds was caused only by sorption at last until its capacity was reached. In bed “I” and “II” the NH4-N concentration in effluent and production of NO2-N with simultaneous changes of NO3-N indicated that nitrification was occurring. The investigation has shown different pattern of processes responsible for nitrogen compounds transformation and removal efficiency, depending on the bed substrate and vegetation. In the second stage the optimization of phosphates removal was carried out. The investigation was conducted in steady conditions in laboratory model with four batch reactors. Each batch reactor of synthetic wastewater with given concentration of phosphates (15 mg/dm3) was subjected to mixing. Samples for analyzing were taken from each beaker after assumed time of sedimentation. Studies were conducted to determine the optimal dose of Phoslock® with known concentration of phosphate anions PO43- in model solution, time of mixing and time of sedimentation. Samples were analyzed with following parameters: pH, total suspended solids, conductivity, turbidity, color and phosphate concentration. The carried out investigations confirmed high efficiency of phosphate anions PO443- removal (over 95%). Also study showed no relationship between the mixing time and the degree of reduction of phosphorus compounds.
Innowacyjne technologie stosowane podczas oczyszczania ścieków powinny spełniać nie tylko wysokie wymagania dotyczące jakości oczyszczonych ścieków, ale także zapewnić maksymalny potencjał odzysku energii i surowców z ścieków. Jednym ze sposobów poprawy skuteczności usuwania związków azotu i fosforu w istniejących konwencjonalnych oczyszczalniach ścieków, jest wstępne oczyszczanie odcieków powstających podczas mechanicznego odwadniania osadu ściekowego po biologicznym oczyszczaniu ścieków. Celem badań było określenie charakterystycznych parametrów procesów technologicznych, dla zapewnienia skutecznego usuwania związków biogennych (N, P) ze ścieków po oczyszczaniu w procesie nitryfikacji/anammox zachodzącym w reaktorze typu SBR. Badanie zostało podzielone na dwa etapy. Pierwszy etap przeprowadzono w celu optymalizacji procesu usuwania związków azotu (NH4-N, NO3-N i NO2-N) z odcieków powstających z mechanicznego odwadniania przefermentowanych osadów ściekowych. Odcieki oczyszczane były w reaktorze SBR w procesie ANAMMOX. Instalacja pilotowa składała się z pojedynczych złóż o przepływie pionowym umieszczonych w zbiornikach ze stali nierdzewnej, pracujących równolegle oznaczonych odpowiednio jako złoże "0", "I", "II". Próbki do analizy pobierano w celu określenia zmian NH4-N, NO3-N i NO2-N w ściekach w każdym ze złóż. W złożu "0" (nie zasiedlonym trzciną) usuwanie związków azotu spowodowane było jedynie przed sorpcję, aż do wyczerpania jego pojemności sorpcyjnej. Natomiast zmiany stężenia NH4-N i wytwarzanie NO2-N przy jednoczesnych zmianach stężenia NO3-N wskazywały na zachodzący proces nitryfikacji w złożach "I" i "II" (oba zasiedlone trzciną). Doświadczenia wykazały różne mechanizmy procesów odpowiedzialnych za przemiany związków azotu i skuteczność ich usuwania, w zależności od podłoża i wegetacji. W drugim etapie badań przeprowadzono optymalizację procesu usuwania fosforanów. Natomiast doświadczenia związane z usuwaniem fosforu zostało przeprowadzone w laboratorium w warunkach nieprzepływowych przy zastosowaniu modelu z czterema reaktorami. Każdy reaktor zawierający ścieki syntetyczne o stężeniu fosforanów 15 mg/dm3 poddano mieszaniu. Próbki do analizy zostały pobierane z każdej zlewki po założonym czasie sedymentacji. Badania przeprowadzono w celu określenia optymalnej dawki preparatu Phoslock® przy znanym stężeniu anionów fosforanowych PO43- w roztworze modelowym, oraz znalezienia optymalnego czasu mieszania i sedymentacji. Próbki poddano analizie i określono następujące parametry: pH, zawiesinę, przewodnictwo, mętność, barwę i stężenie fosforanów. Przeprowadzone badania potwierdziły wysoką skuteczność usuwania PO43- (ponad 95%). Badanie nie wykazało zależności między czasem mieszania a stopniem redukcji związków fosforu.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 143-160
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zrównoważone gospodarowanie ściekami na przykładzie obszarów wiejskich
Sustainable Sewage Management in Rural Areas
Autorzy:
Obarska-Pempkowiak, H.
Kołecka, K.
Gajewska, M.
Wojciechowska, E.
Ostojski, A.
Powiązania:
https://bibliotekanauki.pl/articles/1818174.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczanie ścieków
oczyszczalnie hydrofitowe
gospodarka wodno-ściekowa
sanitacja
zagospodarowanie osadów ściekowych
wastewater treatment
constructed wetlands
water and wastewater management
sanitation
sewage sludge management
Opis:
The Baltic Sea is highly susceptible to eutrophication. Among the nine countries located in the Baltic Sea catchment area Poland discharges the biggest load of nitrogen and phosphorus. Although in recent years this load has been significantly reduced, however it is still too high. No sustainable municipal management results in the decreasing water quality of the Baltic Sea contributing to the sea eutrophication. The implementation of the National Programme for Development of Sewage caused a number of activities related to the construction and modernization of existing wastewater treatment plants. Although the number of wastewater treatment plants has been constantly increasing, still a number of households do not have the possibility to connect to the municipal wastewater treatment plant, mainly for economic reasons. Although in Poland there is 3157 municipal wastewater treatment plants (the most in Central and Eastern Europe), only 64% of the population is connected to them. It is estimated that 7.64 million people do not have the possibility of connection to municipal wastewater treatment plants. One of the solutions to wastewater management, especially in non-urbanized areas, are on-site wastewater treatment plants, for example treatment wetland systems. These technologies provide a sustainable solution of sewage and sludge management, since they can be used not only for treatment of wastewater, but also for dewatering and stabilization of produced sewage sludge. The article presents the results of research on local constructed wetlands for biological wastewater treatment (from 15 to 750 inhabitants) located in Darżlubie, Wieszyno, Wiklino, Sarbsk and Schodno as well as individual treatment wetlands representing 9 on-site wastewater treatment plants built in three different configurations in the municipality of Stężyca. There are also results of research from sludge treatment reed beds used for dewatering and stabilization of sewage sludge from municipal wastewater treatment plants located in Denmark (Helsinge, Rudkobing, Nakskov, Vallo) and in Poland (Gniewino). Based on studies related to the latest examples of wastewater and sewage sludge management using treatment wetlands it has been shown that this method is a good example of ecological engineering. Local treatment wetland systems can be used as the second stage of wastewater treatment up to 3500 residents. With proper operation of primary tanks, these systems are characterized by high treatment efficiency. Treatment wetland systems can work as on-site wastewater treatment plants. The highest efficiency of pollutant removal was observed in the hybrid systems. Another facilities, constructed as reed beds or basins, are applied to effective dewatering and stabilization of sewage sludge. These facilities offer a sustainable solution of sludge management in local conditions.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 1; 585-602
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pre-Feasibility Study for Treatment Wetland Application for Wastewater Treatment in Dispersed Development
Autorzy:
Gajewska, M.
Kołecka, K.
Obarska-Pempkowiak, H.
Wojciechowska, E.
Ostojski, A.
Bejnarowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/124403.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater management in scattered development
conventional and natural treatment methods
economical cost
investment and maintenance costs
Opis:
The aim of the paper is to present the conducted analyses of pre-feasibility study of different approaches for wastewater management in a settlement of 180 persons. In the assessment both technical and economic aspects were analyzed. The costs were calculated for three different and, at the same time, most popular as well as possible technical solutions like: (i) construction of local wastewater treatment plant with gravitational and pressurized networks, (ii) construction of single family wastewater treatment plants, (iii) construction of sealed septic tanks. Carried out analyses of investment and maintenance costs revealed that at the stage of construction the most expensive is local sewer network with treatment plant, while the construction of a single family treatment plant has similar cost regardless of the technology used. When the long term operation and investment cost are accounted the most economical reasonable solution is the application of wetland treatment for household wastewater treatment.
Źródło:
Journal of Ecological Engineering; 2016, 17, 3; 79-86
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies