Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wieczorek, Tomasz" wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Sport injuries in elite amputee football players
Autorzy:
Wieczorek, Jacek
Wieczorek, Andrzej
Bauerfeind, Joanna
Grzelińska, Paula
Śliwowski, Robert
Tasiemski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1055034.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Szczeciński. Wydawnictwo Naukowe Uniwersytetu Szczecińskiego
Tematy:
adapted sports
amputee football
disability
sport games
sport injuries
Opis:
Despite many previous studies dealing with various aspects of physical activity in individuals with an amputation, the risk of injury in amputee footballers has not been assessed thus far. The aim of this study was to characterize the incidence and causes of sport injuries experienced by amputee football players. Furthermore, the incidence of injuries was stratified according to the players’ level of competitive aggressiveness and anger, and their role in the field. The study included 21 members of the Polish National Amputee Football Team, who have been followed-up for a period of 6 months. A total of 16 injuries were recorded, including three that required a medical consultation: luxation of the left elbow, adductor strain and ankle sprain. The group of injuries that have not been consulted with a physician included muscle strains (n = 4), abrasions (n = 3), bruising (n = 3), joint subluxations (n = 2) and luxation (n = 1). The injuries turned out to be more frequent in the lower limbs (n = 10) than in the upper ones (n = 6). The risk of injury turned out to be higher during trainings (n = 9) than matches (n = 7). Amputee football seems to be associated with low risk of injury, since only several bodily contusions were documented throughout the study period. The injuries occurred in 38% of the players; this makes amputee football a relatively safe discipline which can be recommended to physically disabled persons.
Źródło:
Central European Journal of Sport Sciences and Medicine; 2017, 18, 2; 13-22
2300-9705
2353-2807
Pojawia się w:
Central European Journal of Sport Sciences and Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of Microaspiration Around Taperguard Tube Cuffs and Standard Tracheal Tubes in Obese Patients Subjected to Surgery Under General Anesthesia
Autorzy:
Gaszyńska, Ewelina
Ratajczyk, Paweł
Wieczorek, Andrzej
Szewczyk, Tomasz
Gaszyński, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1395728.pdf
Data publikacji:
2014-03-01
Wydawca:
Index Copernicus International
Tematy:
endotracheal intubation
general anesthesia
tracheal tubes
cuff tightness
microaspirations
ventilator-associated pneumonia
Opis:
Tracheal secretion leakage might lead to ventilator-associated pneumonia. Standard tracheal tube cuffs are cylindrical in shape. Bronchial tree aspiration is observed in the presence of leakage past tracheal tube cuffs. The new TaperGuard tracheal tube has a cuff in the shape of a cone, preventing from the development of microtubules and microaspiration. The aim of the study was to compare standard tracheal tube cuffs with TaperGuard tubes, in terms of protection from microaspiration under general anesthesia. Material and methods. The observational study evaluated incidents of leakage during general anesthesia with intubation and mechanical ventilation in patients with significant obesity. The study group comprised 20 patients with the BMI >40 kg/m2 subjected to elective surgery under general anesthesia with intubation and mechanical ventilation, randomly divided into two subgroups: standard tracheal tube and TaperGuard tube. Results. In 4 of 10 patients with standard tracheal tubes we observed leakage around the cuff. In case of TaperGuard tubes no such leakage was observed. Conclusion. TaperGuard tubes protect against microaspirations, while standard tracheal tubes have no such properties.
Źródło:
Polish Journal of Surgery; 2014, 86, 3; 107-110
0032-373X
2299-2847
Pojawia się w:
Polish Journal of Surgery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of haemodynamic effects of noninvasive ventilation delivered via ResQGARD and CPAP boussignac masks
Autorzy:
Gaszyńska, Ewelina
Roguszka, Krzysztof
Stankiewicz- Rudnicki, Michał
Wieczorek, Andrzej
Gaszyński, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1396097.pdf
Data publikacji:
2013-03-01
Wydawca:
Index Copernicus International
Tematy:
mechanical ventilation
haemodynamic CPAP
Impedance Threshold Device
Opis:
Noninvasive ventilation (NIV) is a technique of mechanical ventilation which does not require invasive airway management, i.e. intubation or tracheostomy. In emergency medicine Continuous Positive Airway Pressure (CPAP) is used often. A new method of NIV is Impedance Threshold Device (ITD). Breathing through an ITD is utilized to raise blood pressure in hypotensive patients. Aim of the study was to compare haemodynamic effects of NIV ITD and NIV CPAP. Material and methods. This study involved a group of 25 healthy volunteers. NIV was performed using ResQGARD ITD and CPAP Boussignac. Ventilation time was 25 minutes for each mask in each participant. Every three minutes parameters were collected: SpO2, BP and HR. There was a one hour interval in between ventilation with each mask. CPAP pressure was set at a level of 8 cm H2O and the mean inspiratory resistance of the ITD was 7cm H2O. Collected parameters were subjected to ANOVA statistical analysis. Results. Absolute comparison of BP, HR and SpO2 values did not reveal statistically significant differences between the masks. However considering blood pressure levels at entry, ventilation through an ITD significantly raised BP. Ventilation with NIV CPAP did not change significantly BP. Conclusion. Ventilation through an ITD device significantly improve haemodynamic function, whereas CPAP ventilation had no significant effect on it.
Źródło:
Polish Journal of Surgery; 2013, 85, 3; 129-132
0032-373X
2299-2847
Pojawia się w:
Polish Journal of Surgery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New Test Rig for Measuring the Friction Torque of Gearboxes in Extreme Thermal Conditions
Nowe stanowisko badawcze do pomiaru oporów ruchu przekładni zębatych w ekstremalnych warunkach termicznych
Autorzy:
Tuszyński, Waldemar
Szczerek, Marian
Wulczyński, Jan
Gospodarczyk, Andrzej
Michalczewski, Remigiusz
Samborski, Tomasz
Gibała, Michał
Wieczorek, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/2055627.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
toothed gear
gearbox
friction torque
test rig
extreme thermal conditions
przekładnia zębata
moment rozruchu
moment oporów ruchu
stanowisko badawcze
Opis:
A new test rig for tribological tests was developed and manufactured. It consists of a mobile device for measurement of the start-up friction torque of transmissions, in particular planetary gearboxes, and the friction torque in dynamically steady conditions, as well as a climatic chamber to stabilize the temperature of the tested gearbox in its extreme range: from -50 to +50°C. In the series of devices for tribological tests, developed and manufactured at the Institute, the new test rig is marked with the symbol T-34. The verification results correspond with the churning losses related to the viscosity characteristics of the lubricating oils. As the temperature increases, both the start-up friction torque and the friction torque under dynamically steady conditions decrease.
Przedstawiono nowe stanowisko do badań tribologicznych. Składa się ono z mobilnego urządzenia do badania momentu rozruchowego przekładni zębatych, w szczególności planetarnych, oraz momentu tarcia w warunkach dynamicznie ustalonych, a także z komory klimatycznej do stabilizowania temperatury badanej przekładni w skrajnym jej zakresie: od -50 do +50°C. W typoszeregu urządzeń do badań tribologicznych, opracowanych i wytwarzanych w Instytucie, nowe stanowisko posiada symbol T-34. W ramach weryfikacji działania nowego stanowiska uzyskano wyniki badań momentu tarcia przekładni planetarnych, odpowiadające charakterystyce lepkościowej oleju smarowego. W miarę wzrostu temperatury zarówno moment rozruchowy, jak i moment tarcia w warunkach dynamicznie ustalonych spadają.
Źródło:
Tribologia; 2021, 296, 2; 57--64
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies