Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Uncertainty;" wg kryterium: Temat


Tytuł:
Accuracy analysis of the 2D resistance-to-voltage converters for resistive sensors
Autorzy:
Warsza, Z. L.
Idźkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/114306.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
converter
error
uncertainty
Opis:
The novelty of this work is the analysis of accuracy measures and its visualization especially for the simultaneous two parameter measurements. The parameters of the resistance-to-voltage converters, i.e. different types of DC circuits with arbitrary variable resistive sensors (of relative resistance increments), and their accuracy measures are discussed. Transfer coefficients, limited error (and also standard uncertainty) as functions of relative increments of resistance are shown in broad range for different types of supply and sensor configuration of the circuit of initial 2D converters.
Źródło:
Measurement Automation Monitoring; 2015, 61, 10; 460-464
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental evaluation of dynamic properties of the four electrode reference conductivity cells
Autorzy:
Mikhal, A. A.
Warsza, Z. L.
Gavrylkin, V. G.
Powiązania:
https://bibliotekanauki.pl/articles/114164.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
primary conductivity standard
cell dynamics
uncertainty
Opis:
Dynamic properties of the four-electrode cell with conducting liquid inside are described in the paper. The cell is used as a sensor of the electrolytic conductivity (EC) in the national Ukrainian standard. Electrical model and physical model for the temperature changes of this sensor are presented. To avoid additional measurement errors the stable state in desired temperature should be obtain. To obtain values of parameters describing the dynamic process of EC cell for temperature changes the experimental way was chosen. Installation and measurement procedure is presented. It is found that temperature transition process in the EC cell can be modeled by the first order differential equation and depends mainly on two cell tubes. For establishing the cell temperature within an error less then 0.002ºC time 36 min is needed.
Źródło:
Measurement Automation Monitoring; 2015, 61, 10; 456-459
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uncertainty evaluation of the minimal value measurements
Autorzy:
Dorozhovets, M.
Warsza, Z. L.
Popovych, I.
Powiązania:
https://bibliotekanauki.pl/articles/114616.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
minimal value of observations
uncertainty type A
Opis:
The non-standard statistical method for evaluating uncertainty for a minimal value of observations as the measurement result, is proposed. This method is based on properties of minimal order statistic. As example from the practice this method is used to evaluate the uncertainty of a percent elongation and tensile strength in testing plastic products.
Źródło:
Measurement Automation Monitoring; 2015, 61, 8; 395-398
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
About evaluation of multivariate measurements results
Autorzy:
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/384932.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
uncertainty
indirect measurements
multi-measurand
correlated data
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2012, 6, 4; 27-32
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New approach to the accuracy description of unbalanced bridge circuits with the example of pt sensor resistance bridges
Autorzy:
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/385278.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
resistance bridge
sensor
measures of accuracy
error
uncertainty of measurements
Opis:
After short introduction transfer coefficients of the unloaded four arms bridge of arbitrary variable arm resistances, supplied by current or voltage source, are given in Table 1. Their error propagation formulas are find and two rationalized forms of accuracy measures, i.e. related to the initial bridge sensitivities and of double component form as sum of zero error and increment error of the bridge transfer coefficients are introduced. Both forms of transfer coefficient measures of commonly used bridge - of similar initial arm resistances in balance and different variants of their jointed increments, are given in Table 3. As the example limited errors of some resistance bridges with platinum Pt100 industrial sensors of class A and B are calculated Table 4 and analyzed. Presented approach is discussed and found as the universal solution for all bridges and also for any other circuits used for parametric sensors.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2010, 4, 2; 8-15
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Budowa, analiza i ocena niepewności pomiarów zestawu kalibracyjnego do sprawdzania gazomierzy u użytkownika
Design, theory and accuracy of the calibration device of domestic gas meters "in situ"
Autorzy:
Seredyuk, O.
Vitvitskiy, L.
Vinnichuk, A.
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/155922.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
gazomierz
przenośny kalibrator
niepewność pomiaru
gas meter
mobile calibrator
measurement uncertainty
Opis:
Uzasadniono potrzebę sprawdzania parametrów metrologicznych gazomierzy u odbiorcy bez konieczności ich demontażu i ze stosowaniem gazu ziemnego jako medium roboczego. Omówiono budowę stanowisk do pomiaru przepływu i objętości gazu stosowanych do sprawdzania gazomierzy oraz zaproponowano oryginalną koncepcję rozwiązania przenośnego zestawu kalibracyjnego (kalibratora) z zastosowaniem jako czujników przepływu wywzorcowanych dysz pomiarowych montowanych w instalacji odbiorczej za gazomierzem podłączonym do sieci zasilającej. Opracowano model matematyczny układu pracy kalibratora i oszacowano jego standardową i rozszerzoną niepewność pomiarów. Sformułowano wnioski i podano literaturę. Metoda i oryginalne rozwiązanie tego urządzenia zostało opatentowane w Ukrainie. Powinno ono zainteresować specjalistów i użytkowników gazu z innych krajów, w tym też i z Polski.
In Introduction the need to develop a method and device to control the metrological parameters of household gas meters at their place of operation without dismantling and with using natural gas as a working medium is shortly described. On the analysis base some methods for measurement of the flow and flow volume used to calibration of gas meters of natural gas used in Ukraine and other countries are described, as well as the proposed construction is shown. As reference sensors of flow are used the calibrated nozzles which are mounted in series with the installation of the recipient household gas meter attached to the gas network. Mathematical model of this device has been formulated, and after detailed analysis its standard and extended uncertainty was evaluated. Conclusions and literature is also included. Above calibration method and device was patented in Ukraine and should be of interest for gas specialists in Poland and in other countries.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 1, 1; 9-14
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowy opis miar dokładności mostków sensorowych o dużych zmianach rezystancji
New description of the accuracy measures of sensor bridges of broadly variable resis-tances
Autorzy:
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/156946.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
mostek
czujnik rezystancyjny
błąd
niepewność
bridge
resistance sensor
accuracy
error
uncertainty
Opis:
Po wprowadzeniu podano zracjonalizowane postacie iloczynowe rozwarciowych funkcji przetwarzania i miary ich dokładności dla nieobciążonego mostka 4R o zasilaniu prądowym lub napięciowym przy dowolnych wartościach jego rezystancji - tabela 1. Zaproponowano ujęcie dwuskładnikowe jako sumę miar stanu początkowego i przyrostu funkcji przetwarzania. Omówiono miary mostka o jednakowych rezystancjach początkowych i pięciu wariantach ich przyrostów - tabela 2. Dla mostków o liniowych funkcjach przetwarzania podano uogólnione postacie błędów granicznych. Wskazano inne możliwości zastosowania tych opisów miar.
After introduction, transfer functions and their rationalized forms for the unloaded four arms bridge of arbitrary variable arm resistances, supplied as twoport by current or voltage source are given in table 1. Based on their error propagation formulas two types of accuracy measures are introduced, i.e. related to initial sensi-tivities and double components form for zero and increment of the transfer functions. Metrological properties of commonly used the bridge of similar initial arm resistances in balance and different five variants of their increments are given in Table 2 and discussed. Generalized formulas of limited error for linear bridges are introduced. Both methods may be applied also for many of parametric sensor circuits.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 5, 5; 457-463
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza błędów granicznych i niepewności mostków sensorowych jako przetworników rezystancji na napięcie
Functions of limit errors and uncertainties of sensor bridges as resistance to voltage converters
Autorzy:
Warsza, Z. L.
Idźkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/152751.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przetwornik
mostek rezystancyjny
błąd
niepewność
converter
resistance bridge
accuracy
error
uncertainty
Opis:
Po krótkim wprowadzeniu w tabeli 1 podano funkcje rozwarciowych współczynników przetwarzania rezystancji na napięcie i ich zracjonalizowane postacie iloczynowe dla przetwornika w postaci mostka rezystancyjnego (4R) o zasilaniu prądowym lub napięciowym i dowolnych przyrostach rezystancji jego ramion. Przedstawiono dwa zaproponowane ujęcia błędów i niepewności: jednorodne, w wartościach względnych odniesionych do czułości początkowych i dwuskładnikowe – z wyodrębnieniem składników dla stanu początkowego i dla przyrostu funkcji przetwarzania. Rozpatrzono przetworniki rezystancji – mostki, o jednakowych rezystancjach początkowych i pięciu najczęściej stosowanych wariantach ich przyrostów. Przedstawiono charakterystyki ich rozwarciowych funkcji przetwarzania oraz błędów granicznych i niepewności standardowych przy zasilaniu prądowym i napięciowym. Dla wariantów mostka o liniowych funkcjach przetwarzania podano dwie uogólnione postacie błędów granicznych. Wskazano możliwości zastosowania obu opisów dokładności.
After short introduction, in table 1 functions of transfer coefficients and their rationalized forms of the converter R/U as the unloaded four arms bridge of arbitrary variable arm resistances, supplied from current or voltage source, are given together with their error propagation formulas. Two types of description of their errors and uncertainties, i.e. related to initial sensitivities of functions of bridge transfer coefficients and their rationalized double component forms for zero and increments of these transfer function, are introduced. Metrological properties of the commonly used bridge of similar initial arm resistances in balance and five variants of their increments are discussed. Transfer coefficient, limited error (worse case) and standard uncertainty as functions of relative increments in broad range are shown for these variants. Generalized formulas for bridges of the linear transfer function are introduced. Both methods are found also as the universal solution for other parametric sensor circuits.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 6, 6; 548-553
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effective Measyrand Estimators for Samples of Trapezoidal PDF-s
Autorzy:
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/384747.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
estimators of probability density function
trapezoidal PDF
mid-range
uncertainty evaluation
Opis:
This paper is final overview of investigations on the accuracy of basic estimators of trapezoidal probability distribution samples of the measured data. For symmetrical trapezoidal PDF of straight as well concaved sides, using Monte-Carlo method of simulation, the standard deviation (SD) of linear 1- and 2-component estimators are evaluated. Approaches for theirs evaluation are proposed. It is established that in the ratio of upper and bottom bases of trapezoidal PDF in the range from 1 to 0,35 the mid-range value has smaller standard deviation (SD) than the mean value and median. It is find then for the whole family of the symmetric linear trapezoidal PDF more accurate than above single element estimators are two-component (2C) estimators as the linear form of the mean and mid-range values of the sample. Their coefficients are found, properties discussed and formulas of SD are given. The new simplified 2C-estimator of equal coefficients is also proposed. These estimators successfully extend estimation of the measurand value as the sample mean and description of its accuracy by the uncertainty type A recommended by the international guides of uncertainty evaluation in measurement GUM-2008 [1], EA-4/02 [2] and by Handbook NASA [3]. Approaches of described below investigations could be effectively applied also for other models of convoluted PDF-s.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2012, 6, 1; 8-14
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie niepewności typu A pomiarów o skorelowanych rezultatach obserwacji
Evaluation of the uncertainty type A of autocorrelated measurement observations
Autorzy:
Dorozhovets, M.
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/152484.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
niepewność typu A
autokorelacja
rozkład prawdopodobieństwa
type A uncertainty
autocorrelation
random distribution
Opis:
Omówiono zasięg i ograniczenie zasad wyznaczania parametrów niepewności pomiarów wg zaleceń międzynarodowych zawartych w publikacji nazywanej akronimem GUM [1, 2]. Podano propozycję rozszerzenia zakresu stosowania obliczeń niepewności wyznaczanej metodą typu A obejmującą uwzględnienie w pomiarach wpływu skorelowania skorygowanych obserwacji. Polega ona na wprowadzeniu efektywnej liczby obserwacji. Jest ona mniejsza od rzeczywistej i oblicza się ją z funkcji autokorelacji. Proponowane rozszerzenie metody obliczeń niepewności typu A zilustrowano przykładem liczbowym zawierającym też jako poprzedzające operacje usunięcie trendu z "surowych" wartości obserwacji i sprawdzenie wybranego typu rozkładu.
Principles of the estimation of uncertainty parameters introduced by the international guide named by acronym GUM [1] are given and their scope and limitations are discussed. Proposals of expanding the application range of the uncertainty evaluated by the type A method to the measurement in the case of correlated observations are presented. Effective number of observations is introduced, smaller then real one. It is calculated from the autocorrelation function of corrected observations. Proposed method has been illustrated by the numerical example included also as the beginning operations the linear trend elimination from uncorrected observation results and testing the chosed type of distribution.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 2, 2; 20-24
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Udoskonalenie metody typu A wyznaczania niepewności pomiarów. Wykrywanie i eliminacja wpływu dryftu i oscylacji przy równomiernym próbkowaniu.
Methods of upgrading the uncertainty of type A evaluation Discovering and elimination the influence of drift and harmonic components for regular sampling
Autorzy:
Dorozhovets, M.
Warsza, Z. L.
Korczyński, M. J.
Powiązania:
https://bibliotekanauki.pl/articles/158021.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
niepewność
składowe systematyczne
dryft
zakłócenia oscylacyjne
uncertainty
systematic components
trend
harmonic disturbances
Opis:
Zaproponowano udoskonalenie metody typu A szacowania niepewności zalecanej przez przewodnik ISO GUM. Polega ono na wykryciu nieznanego a priori trendu i podstawowej składowej oscylacyjnej w surowych wynikach obserwacji pomiarowych oraz ich wyeliminowaniu. Dla dwu przykładów liczbowych przedstawiono i omówiono wpływ takiego "czyszczenia" wyników surowych ze składowych systematycznych na wartość odchylenia standardowego próbki.
A new approach to upgrading the type A uncertainty evaluation due ISO GUM recommendations is presented in this paper. The "cleaning" of raw data set by elimination the systematic components as trend and periodical ones and the influence of this cleanings on standard uncertainty type A is presented and disused on two numerical examples.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 12, 12; 8-11
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ nieadekwatnego wyboru parametrów rozkładu prawdopodobieństwa na niepewność typu A
Influence of the inadequate choice of distribution parameters on the uncertainty evaluated by method type A
Autorzy:
Dorozhovets, M.
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/157410.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiar
niepewność typu A
rozkład prawdopodobieństwa
measurement
type A uncertainty
random distribution
Opis:
Zaproponowano rozszerzenie wyznaczania niepewności pomiarów metodą statystyczną typu A zalecaną przez międzynarodowy przewodnik GUM. Po wyeliminowaniu trendu z obserwacji pomiarowych i uwzględnieniu wpływu autokorelacji wybiera się właściwy rozkład prawdopodobieństwa stosując kryterium x2 i najbardziej wiarygodny statystycznie jego parametr. Podano przykład procedury wyznaczania środka rozstępu jego odchylenia standardowego dla rozkładu jednostajnego oraz mediany dla rozkładu dwuwykładniczego Laplace`a, jako najdokładniejszych parametrów tych rozkładów. Porównano je z parametrami zalecanymi przez GUM. Zamieszczono wnioski i literaturę.
Proposal of the development of the method type A evaluation of the measurement uncertainty recommended by ISO international guide is given. It contains of choosing the adequate probability distribution using the x2 criterion and its the most likelihood parameter. The numerical example of the midrange and its standard deviation calculations of the rectangular distribution and median (MED) of Laplace double-exponential one is presented. They are compared to parameters recommended by GUM. Summary and literature is included.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 25-28
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Robust estimation in interlaboratory measurements with small number of measurements
Autorzy:
Volodarsky, E. T.
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/114483.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interlaboratory comparisons
proficiency testing of laboratory outliers
robust statistics
precision
uncertainty of measurements
Opis:
In this paper two robust methods of assessing the value and the uncertainty of the measurand from the samples of small number of experimental data are presented and compared. Those methods can be used when some measurements results contain outliers, i.e. when the values of certain measurement results significantly differ from the others. They allow to set a credible statistical parameters of the measurements with the use of all experimental data. The following considerations are illustrated by the numerical examples of multi-laboratory measurement data key comparison. Compared are the results obtained by a classical method with rejection of outliers with two robust methods: a rescaled median absolute deviation MADS and an iterative two-criteria method. The paper also presents the advantages of the robust iterative statistical method in estimating the accuracy of the tested laboratory measurement results during its accreditation on the sample of four elements with outlier. A comparison with the estimates obtained by the standard procedure for evaluating performance accuracy is also provided.
Źródło:
Measurement Automation Monitoring; 2015, 61, 4; 104-110
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Robust Algorithm S to assess the precision of interlaboratory measurements
Autorzy:
Volodarsky, E. T.
Warsza, Z. L.
Kosheva, L.
Idźkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/114514.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
robust statistics
algorithm S
test laboratory
comparability and acceptability of interlaboratory results
uncertainty
Opis:
The application of robust statistical methods to assess the precision (uncertainty) of the results of interlaboratory comparison tests is presented. The case, when these results may include outliers is considered. An usual rejection of such data reduces the reliability of evaluation, especially for small samples. The robust methods take into consideration all samples data including outliers. The use of the robust method Algorithm S is provided for estimating the precision of some measuring method tested in comparative studies in the group of accredited laboratories. Result obtained for simulated example is very close to the case with rejection outliers, but more reliable.
Źródło:
Measurement Automation Monitoring; 2015, 61, 4; 111-114
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sugestie kilku uściśleń w Przewodniku GUM-2008 i zaokrąglanie wyników pomiarów wieloparametrowych
Some upgrading suggestions of the GUM-2008 and rounding rules for multivariate measurement results
Autorzy:
Warsza, Z. L.
Ezhela, V. V.
Powiązania:
https://bibliotekanauki.pl/articles/157304.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary pośrednie wieloparametrowe
niepewność multimezurandu
korelacja danych
uncertainty
multidimensional indirect measurements
data correlation
Opis:
W pracy wykazano, że kilka zaleceń Przewodnika GUM o wyrażaniu wyników pomiaru jest niewłaściwych dla poprawnego przetwarzania danych w pośrednich pomiarach wieloparametrowych, a w przykładzie H.2 nie oszacowano poprawnie korelatora. Podano progi ograniczające minimalne liczby cyfr przy jednolitym zaokrąglaniu danych liczbowych multimezurandu z przykładami oraz proponowane zasady dalszego zaokrąglania poniżej tych progów. Zaproponowano kilka zmian w GUM. Z pracy wynika, że pilnie potrzebne są międzynarodowe zalecenia do poprawnego wyznaczania wyników pomiarów wieloparametrowych (Suplement 2 do GUM) oraz normalizacja prezentacji numerycznej ich danych.
this paper it is shown that recommendations of evaluation estima-tors of the value, uncertainty and correlation coefficients given by the international metrological Guide GUM-2008 are not useful enough for the proper evaluation of results in multidimensional indirect measurements. Mistakes are shortly discussed. It is found that smallest eigenvalue of correlation matrix obtained after calculations for output multi-measurand in the GUM H.2 example is negative and data is not proper as cannot be presented by 3-order normal distribution. Output data of the H.2 example are evaluated by two cases. First one is reference - when input data are considered as given absolutely accurate and thresholds of safety rounding calculating from them output data are find. In the second case, proper to wide application, method rounding of output is joined with accuracy of uncertainty of input data. Two variants of this method are compared. Few corrections of H.2 example are proposed. Formulas for the proper rounding of the multi-measurand numerical data up to thresholds, and recommendations for rounding below them are given. The minimal data structure for describing the multi-measurand is defined. From this work it results that in multivariable measurements urgently is needed standardization of the method of measurement data evaluation (Supplement 2), and also for their presentation which allows full numerical review of the multidimensional data, their wide dissemination and unlimited in time storage.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 3, 3; 291-296
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies