Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "He, S." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Design and test of a new high-current electronic current transformer with a Rogowski coil
Autorzy:
Zhang, M.
Li, K.
He, S.
Wang, J.
Powiązania:
https://bibliotekanauki.pl/articles/221051.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Rogowski coil
high-current
electronic current transformers
electrical measurements
Opis:
This paper describes the design and test of a new high-current electronic current transformer based on a Rogowski coil. For better performances, electronic current transformers are used to replace conventional electro-magnetic inductive current transformers based on ferromagnetic cores and windings to measure high-current on the high voltage distribution grids. The design of a new high-current electronic current transformer is described in this paper. The principal schemes of the prototype and partial evaluation results are presented. Through relative tests it is known that the prototype has a wide dynamic range and frequency band, and it can allow high accuracy measurements.
Źródło:
Metrology and Measurement Systems; 2014, 21, 1; 121-132
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An on-site calibration system for electronic instrument transformers based on LabVIEW
Autorzy:
Zhang, M.
Li, K.
Wang, J.
He, S.
Powiązania:
https://bibliotekanauki.pl/articles/221656.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
calibration system
electronic instrument transformers
data acquisition
data synchronization
LabVIEW
Opis:
Electronic voltage transformers (EVT) and electronic current transformers (ECT) are important instruments in a digital substation. For simple, rapid and convenient development, the paper proposed an on-site calibration system for electronic instrument transformers based on LabVIEW. In the system, analog signal sampling precision and dynamic range are guaranteed by the Agilent 3458A digital multimeter, and data synchronization is also achieved based on a self-developed PCI synchronization card. To improve the measurement accuracy, an error correction algorithm based on the Hanning window interpolation FFT has good suppression of frequency fluctuation and inter-harmonics interference. The human-computer interface and analysis algorithm are designed based on LabVIEW, and the adaptive communication technology is designed based on IEC61850 9-1/2. The calibration system can take into account pairs of digital output and analog output of the electronic voltage/current transformer calibration. The results of system tests show that the calibration system can meet the requirements of 0.2 class calibration accuracy, and the actual type test and on-site calibration also show that the system is easy to operate with convenience and satisfactory stability.
Źródło:
Metrology and Measurement Systems; 2014, 21, 2; 257-270
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adsorption behavior of surfactants on lignite particles with different densities in aqueous medium
Autorzy:
Wang, J.
He, Y.
Wen, B.
Ling, X.
Xie, W.
Wang, S.
Powiązania:
https://bibliotekanauki.pl/articles/110538.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
interfacial surface free energy
adsorption
lignite
surfactant
Washburn equation
Opis:
Lignite is well known for its strong hydrophilicity and hard-to-float properties. However, the surface free energy of the solid is made up of two components, that is the Lifshitz-van der Waals and acid-base interaction energy. Differences in these two components between the low ash (lower density) and high ash fraction (higher density) provide a benefit for improving the separation efficiency through introducing surfactants in flotation. In this paper, thermodynamic characterization of three density lignite fractions was measured by a Washburn dynamic method. Combining the Washburn equation and Van Oss-Chaudhury-Good theory, the surface free energy components of three samples were calculated according to the wetting process by n-hexane, diiodomethane, deionized water and ethylene glycol. The Lifshitz-van der Waals part of surface free energy reduced with the coal density increase, especially between fractions of -1.45 g/cm3 and 1.45-1.80 g/cm3, while the Lewis base part increased slightly. The interfacial interaction free energies between the surfactant and lignite in aqueous medium indicated that the low hydrophilic index benefited for the stronger adsorption intensity. Increase of the surfactant Lifshitz-van der Waals component increases the adsorptive intensity on lower density lignite and the repulsive intensity on higher density lignite, which is beneficial for separation.
Źródło:
Physicochemical Problems of Mineral Processing; 2017, 53, 2; 996-1008
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies