Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wojcik, A" wg kryterium: Autor


Tytuł:
Example of Structure Modeling and Analysis of Ultrasound Scattering for Trabecular Bone
Autorzy:
Wójcik, J.
Litniewski, J.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/177853.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multi-scattering
random complex structures
trabecular bone model
Opis:
A trabecular bone consists of trabeculae whose mechanical properties differ significantly from the surrounding marrow, therefore an ultrasonic wave propagating within the bone structure is strongly scattered. The aim of this paper was to evaluate the contribution of the first, second and higher order scattering (multiple scattering) into the total scattering of ultrasound in a trabecular bone. The scattering due to the interconnections between thick trabeculae, usually neglected in trabecular bone models, has been also studied. The basic element in our model of the trabecular bone was an elastic cylinder with a various finite-length and diameter as well as orientation. The applied model was taking into account variation of both, elements size and their spatial configuration. The field scattered on the bone model was evaluated by solving numerically the integral form of the generalized Sturm-Liouville equation describing a scalar wave in inhomogeneous and lossy media. For the scattered fields calculated numerically the effective cross-sections were determined. The influence of absorption on the scattering coefficients was demonstrated. The results allowed to conclude that within the frequency range from 0.5 to 1.5 MHz contribution of the second order scattering to the effective backscattering cross-section is at least 500 times lower than that due to the first order scattering. It was noticed that for a frequency higher than 1.5 MHz fast growth of the backscattering (reflection) coefficients, calculated for the second order scattering, occurs.
Źródło:
Archives of Acoustics; 2010, 35, 4; 701-713
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using Empirical Mode Decomposition of Backscattered Ultrasound Signal Power Spectrum for Assessment of Tissue Compression
Autorzy:
Byra, M.
Wójcik, J.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/177950.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
tissue characterization
tissue compression
quantitative ultrasound
empirical mode decomposition
signal analysis
Opis:
Quantitative ultrasound has been widely used for tissue characterization. In this paper we propose a new approach for tissue compression assessment. The proposed method employs the relation between the tissue scatterers’ local spatial distribution and the resulting frequency power spectrum of the backscattered ultrasonic signal. We show that due to spatial distribution of the scatterers, the power spectrum exhibits characteristic variations. These variations can be extracted using the empirical mode decomposition and analyzed. Validation of our approach is performed by simulations and in-vitro experiments using a tissue sample under compression. The scatterers in the compressed tissue sample approach each other and consequently, the power spectrum of the backscattered signal is modified. We present how to assess this phenomenon with our method. The proposed in this paper approach is general and may provide useful information on tissue scattering properties.
Źródło:
Archives of Acoustics; 2018, 43, 3; 447-453
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical modeling of ultrasound-induced temperature fields in multilayer nonlinear attenuating media
Autorzy:
Kujawska, T.
Wójcik, J.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/332786.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
numerical modeling
ultrasound
attenuating media
Opis:
Ultrasound is a safe, convenient and inexpensive modality which may be useful for soft tissues treatment. A range of beneficial biological effects induced by ultrasound depends on the exposure levels used during treatment. At high intensities instantaneous tissue necrosis is desired, whereas at lower intensities remedial reversible cellular effects may be produced. For example, increasing of cells immunity against stress can be obtained through the heat shock proteins (Hsp) expression enhancement. The possibility of the Hsp expression enhancement in soft tissues in vivo by means of controlled exposure to ultrasound would allow to evaluate the treatment efficiency. Ultrasonic regimes can be controlled by adjusting the ultrasound intensity, frequency, pulse duration, duty cycle and exposure time. The goal of this work was to develop the numerical model capable of predicting in space and time the temperature fields induced by circular focused transducer generating tone bursts in multilayer nonlinear attenuating media, which is intended for the Hsp expression enhancement therapeutic application. The acoustic pulsed pressure field generated from the transducer was calculated using our original 3D numerical solver [1]. For prediction of the temperature distributions in multilayer biological media the Pennes bio-heat transfer equation was numerically solved. The 3D temperature fields induced in a rat liver in vitro by a 2 MHz transducer with 15 mm diameter and 25 mm focal length during ultrasonic Hsp expression enhancement treatment using various acoustic beam intensities and exposure time was predicted.
Źródło:
Hydroacoustics; 2009, 12; 91-97
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy przenoszenia skali w krystalizatorach z rurą cyrkulacyjną i mieszadłem
Scale-up problems in crystallizers with the draft tube and propeller
Autorzy:
Małysiak, A.
Synowiec, M.
Wójcik, J.
Powiązania:
https://bibliotekanauki.pl/articles/1215668.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
przenoszenie skali
krystalizator DTM
czas pierwotnej cyrkulacji
scale-up
DTM crystallizer
primary circulation time
Opis:
W artykule przedstawiono analizę zagadnienia przenoszenia skali na przykładzie jednego z typów krystalizatora powszechnie stosowanego w aplikacjach przemysłowych. Zdefiniowano istotny parametr procesowym, mający duży wpływ na powtarzalność technologii. Określono wymagania z punktu widzenia kinetyki procesu podczas przenoszenia skali oraz, biorąc pod uwagę najczęściej stosowaną procedurę, przeanalizowano możliwości i ograniczenia tego sposobu.
The paper deals with scale-up problems. The issue is discussed in the light of draft tube magma crystallizer, commonly used in crystallization processes from solution. Authors defined the parameters mainly affecting the crystallization and product requirements during scale-up on one hand and on another consider, what can be done when the traditional procedure is applied.
Źródło:
Chemik; 2014, 68, 3; 202-204
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multitone nonlinear coding
Autorzy:
Nowicki, A.
Wójcik, J.
Secomski, W.
Powiązania:
https://bibliotekanauki.pl/articles/331604.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
MNC method
virtual fields
acoustic source
Opis:
A new method that utilizes nonlinear properties of tissue (or another media) to improve ultrasound image resolution is presented. In our novel method the acoustic source is activated with two tones burst (2.2 and 4.4 MHz) with specially designed polarization of the individual tone burst. This new approach is called multi tone nonlinear coding MNC because the choice of polarization of the both tones (and their amplitudes) allowing optimization of the receiving properties depends on the nonlinear properties of tissue. The calculations were done for two tones bursts propagating in the tissue-like lossy medium with absorption of 7 Np/mźMHz. The concept of the Virtual Fields was introduced to explain abilities and properties of pulse inversion and MNC method and to compare both. Comparison of the spatial field distribution obtained using MNC and conventional harmonic imaging approach, in which the first harmonic is used to reconstruct the image are presented.
Źródło:
Hydroacoustics; 2008, 11; 289-298
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A spectral-based method for tissue characterization
Autorzy:
Wójcik, J.
Byra, M.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/331796.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
quantitative ultrasound
signal analysis
wave scattering
Opis:
Quantitative ultrasound methods are widely investigated as a promising tool for tissue characterization. In this paper, a novel quantitative method is developed which can be used to assess scattering properties of tissues. The proposed method is based on analysis of oscillations of the backscattered echo power spectrum. It is shown that these oscillations of the power spectrum are connected with the distances between scatterers within the medium. Two techniques are proposed to assess the scatterer’s distribution. First, we show that the inverse Fourier transform of the backscattered echo power spectrum corresponds to a histogram of the distances between scatterers. Second, the Hilbert-Huang transform is used to directly extract the power spectrum oscillations. Both methods are examined by means of a numerical experiment. A cellular gas model of a biological medium is considered. Results are presented and discussed. Both methods can be used to evaluate the scatterer’s distribution by means of the power spectrum oscillations.
Źródło:
Hydroacoustics; 2016, 19; 369-375
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature fields induced in rat liver in vitro by pulsed low intensity focused ultrasound
Autorzy:
Kujawska, T.
Wójcik, J.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/331934.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
Beneficial biological effects in soft tissues can be induced by focused ultrasound of low intensity (LIFU). For example, increasing of cells immunity to stress can be accomplished through the enhanced heat shock proteins (Hsp) expression induced by the low intensity focused ultrasound. The possibility to control the Hsp expression enhancement in soft tissues in vivo can be the potential new therapeutic approach to neurodegenerative diseases that utilizes the known feature of cells to increase their immunity to stresses through the Hsp expression enhancement. The controlling of the Hsp expression enhancement by adjusting the level of exposure to ultrasound energy would allow evaluating of ultrasound-mediated treatment efficiency. Our objective was to develop the numerical model capable of predicting in space and time temperature fields induced in multilayer nonlinear attenuating media by a circular focused transducer generating pulsed acoustic waves and to compare the results calculated for two-layer configuration of media: water - fresh rat liver with the experimental data. The measurements of temperature variations versus time at 5 points on the acoustic beam axis within the tissue sample were performed using 0.2-mm diameter thermocouples. Temperature fields were induced by the transducer with 15-mm diameter, 25-mm focal length and 2-MHz centre frequency generating tone bursts with the intensity ISPTA varied between 0.45 W/cm2 and 1.7 W/cm2 and duration varied between 20 and 500 cycles at the same 20-% duty cycle and 20-min exposure time. Quantitative analysis of the obtained results allowed to show that, for example, for the acoustic beam with intensity ISPTA = 1.13 W/cm2 exposure time to ultrasound should not be longer than 10 min to avoid cells necrosis following the 43-oC temperature threshold exceeding.
Źródło:
Hydroacoustics; 2010, 13; 153-162
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nonlinear ultrasound propagation in water from square focused transducer
Autorzy:
Kujawska, T.
Wójcik, J.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/332715.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
The nonlinear pulsed acoustic pressure field from a focused square aperture is considered. Experimental measurements in water of a 4D sound field radiated from a 2.8 MHz focused square transducer of a 20 mm side and a 80 mm focal distance for excitation level producing an average acoustic pressure P0 = 0.14 MPa at its surface are presented. The obtained results are compared with the numerical calculation results for the same boundary conditions. The novel, free from paraxial approximation and computationally efficient numerical algorithm was used to simulate the 4D nonlinear pulsed pressure field from the nonaxisymmetric acoustic source. Our theoretical model was based on the Time-Averaged Pressure Envelope (TAPE) method recently developed that enable to represent the propagated pulsed disturbance as a superposition of sinusoidal wavelets with carrier frequencies being the harmonics of the initial tone burst and with envelopes determined by the TAPE method. The novel approach to the solution of the nonlinear wave equation enabled to simulate full 4D nonlinear field for given boundary conditions in a dozen or so minutes utilizing the computational power of the standard PC.
Źródło:
Hydroacoustics; 2005, 8; 89-98
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Acoustic streaming generated by ultrasonic transducers, measurements by means of 32 MHz Doppler
Autorzy:
Nowicki, A.
Secomski, W.
Wójcik, J.
Powiązania:
https://bibliotekanauki.pl/articles/332760.pdf
Data publikacji:
1997
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
An approximate solution for the streaming velocity generated by flat and weakly focused transducers was derived by directly solving the Dirichlet boundary conditions for the Poisson equation. The theoretical calculations were verified using a purpose-designed 32 MHz pulsed Doppler unit. The applied average acoustic power was changed from l µW to 6 mW. The experiments were done on 4 mm diameter flat and focused transducers. The streaming velocity was measured along the ultrasonic beam from 0 to 20 mm. Streaming was induced in a solution of water and com starch. The experimental results showed that for a given acoustic power the streaming velocity was independent of the starch density in water changed from 0.3 grams to 40 grams of starch in 1 litre of distilled water. For applied acoustic powers, the streaming velocity changed Iinearly from 0.2 to 40 mm/s. Both, the theoretical solutions for pIane and focused waves, and the experimental results were in good agreement.
Źródło:
Hydroacoustics; 1997, 1; 337-342
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiple scattering contribution to trabecular bone backscatter
Autorzy:
Wójcik, J.
Litniewski, J.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/332838.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
bone backscatter
integral equations
spectral distribution
Opis:
Integral equations that describe scattering on the structure with step rise parameters, have been numerically solved on example of the trabecular bone model. The model consists of several hundred elements with randomly selected parameters. The spectral distribution of scatter coefficients in subsequent orders of scattering has been presented.
Źródło:
Hydroacoustics; 2009, 12; 227-236
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Plonowanie i jakość surowca bazylii pospolitej, cząbru ogrodowego, majeranku grodowego oraz tymianku właściwego w uprawie ekologicznej na stanowisku po oborniku
Yield and quality of sweet basil, savory, marjoram and thyme raw materials from organic cultivation on the composted manure
Autorzy:
Seidler-Łożykowska, K.
Golcz, A.
Wójcik, J.
Powiązania:
https://bibliotekanauki.pl/articles/336843.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
bazylia
plonowanie
cząber
majeranek
jakość
tymianek
uprawa ekologiczna
obornik
yield
quality
sweet basil
savory
marjoram
thyme
manure
orginic cultivation
Opis:
W latach 2006-2007, w doświadczeniach polowych oceniono plonowanie i jakość surowców polskich odmian bazylii, cząbru, majeranku oraz tymianku uprawianych na stanowiskach w pierwszym i drugim roku po oborniku. W doświadczeniach badano następujące cechy: plon surowca świeżego oraz otartego, zawartość łodyg w surowcu, zawartość olejku eterycznego i składników mineralnych w surowcu oraz czystość mikrobiologiczną surowca. Uzyskane wyniki wskazują, że cząber, majeranek i tymianek lepiej plonowały w uprawie po oborniku. Uprawa na stanowiskach po oborniku nie wpływała na zawartość łodyg w surowców wszystkich badanych gatunków. Surowce badanych gatunków uprawiane po oborniku zawierały więcej olejków eterycznych niż pochodzące z uprawy konwencjonalnej. Surowce bazylii, majeranku i tymianku uprawiane w pierwszym roku po oborniku gromadziły najwięcej azotanów. Surowiec bazylii uprawianej po oborniku, w porównaniu z innymi gatunkami, zawierał najwięcej fosforu, potasu, wapnia, magnezu, manganu i cynku. Surowce uprawiane w pierwszym roku po oborniku charakteryzowały się zwiększoną liczbą bakterii tlenowych oraz grzybów drożdżoidalnych i pleśniowych, ale ich czystość mikrobiologiczna nie przekraczała dopuszczalnych norm.
In 2006-2007, yield and quality of sweet basil, savory, marjoram and thyme raw materials cultivated in I and II years on the composted manure were evaluated in the field experiments. The following traits were estimated: yield of fresh herb, yield of dried herb without stems, stem content in herb, essential oil content, mineral elements content and microbiological contamination. Savory, marjoram and thyme cultivated on the composted manure gave better yields of herb. Cultivation on the composted manure did not affect on the content of stems in the dried herb. The raw materials of the tested herbs obtained from the field composted manure contained more essential oils in compared with these from conventional cultivation. The raw materials of sweet basil, marjoram and thyme from the first year cultivation after manure application contained more nitrate. Herb of sweet basil cultivated on the composted manure contained more phosphorus, potassium, calcium, magnesium, manganese and zinc compared to other tested herbs. The raw materials of all herbs obtained from the first year cultivation after manure application were characterized by the highest microbiological contamination, although it was still below the accepted level of standard one.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2008, 53, 4; 63-66
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wytrzymałość mechaniczna światłowodów fotonicznych
Mechanic reliability of photonic crystal fibres
Autorzy:
Wójcik, J.
Matusewicz, M. A.
Mergo, P.
Walewski, A.
Powiązania:
https://bibliotekanauki.pl/articles/157056.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
światłowód fotoniczny
światłowód klasyczny
wytrzymałość mechaniczna
photonic crystal fibre
classical fibre
mechanical reliability
Opis:
Pękanie szkła prawie zawsze zaczyna się od defektów na jego powierzchni. Powierzchnia zewnętrzna klasycznych światłowodów jest osłonięta powłokami ochronnymi chroniącymi ją przed oddziaływaniem zewnętrznych czynników chemicznych i mechanicznych. Włókna fotoniczne, oprócz chronionej zewnętrznej powierzchni szkła mają też powierzchnię wewnętrzną nawet o rząd większą od zewnętrznej. Ta wewnętrzna powierzchnia nie jest narażona na działanie czynników mechanicznych, ale nie jest chroniona przed czynnikami chemicznymi, zwłaszcza przed oddziaływaniem pary wodnej. Hipoteza o mniejszej wytrzymałości mechanicznej światłowodów fotonicznych w porównaniu z klasycznymi została wstępnie potwierdzona w naszych poprzednich pracach [1]. Niniejsza praca prezentuje ilościowy opis wytrzymałości mechanicznej dwóch omawianych rodzajów włókien. Światłowód klasyczny stanowił ślepą próbę dla światłowodu fotonicznego w badaniach wytrzymałości mechanicznej przy użyciu zrywarki Tira Test 2200 przystosowanej do pomiarów wytrzymałości światłowodów. Zarówno histogramy jak i rozkłady Weibulla dla obu włókien ilościowo potwierdzają mniejszą wytrzymałość mechaniczną światłowodów fotonicznych. Dodatkowym potwierdzeniem wyników są faktograficzne badania przełomów światłowodów.
Most of the glass fractures start from flaws on the glass surface. The outer surface of optical fibres is protected from the influence of mechanical and chemical factors by a thin layer of polymer protective coating. Photonic crystal fibres have, besides outer glass surface, inner glass surface of even an order of magnitude greater area. This inner surface is not exposed to mechanical factors. However, it is not protected from chemical agents, most importantly - water vapour. Hypothesis of relatively lower mechanical reliability of photonic crystal fibres in comparison to classical optical fibres was initially confirmed in our previous works [1]. This work con-tains quantitative mechanical reliability description of two kinds of optical fibres mentioned above. The classical and photonic crystal fibre, both manufactured in our laboratory, had their mechanical reliability tested on the Tira Test 2200 tensile testing machine adapted for testing optical fibres. Histograms and Weibull distributions show lower mechanical reliability of photonic crystal fibres. Additional confirmation comes from fractographic studies of fracture surfaces. The presented work is a part of research carried out in PHOSFOS project within the framework of EU Seventh Framework Programme.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 5, 5; 430-432
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cumulative method of the image reconstruction in synthetic aperture. Experimental results
Autorzy:
Wójcik, J.
Trots, I.
Lewandowski, M.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/331922.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
An analytical model of imaging using synthetic aperture (SA) methods is presented. This model takes into account: fundamental features of an environment, of an electric transmission/reception path and a description of SA structure – possible schemes of transmission, reception and image formation. Then two schemes are analyzed: a proposed cumulative synthetic transmit aperture (CSTA) and for comparison of the standard STA schemes. For both methods identical basic parameters – equal sequences of transmit and receive transducers were applied. The distinctive feature of CSTA is gathering (summing up) echoes of subsequent transmissions in one acquisition matrix sufficient for image reconstruction. In traditionally applied STA methods a separate acquisition matrix for each transmission is created. Therefore there are a dozen to several dozen more matrices and the time of image reconstruction is at least several times longer than in CSTA. The presented experimental results obtained using wire and tissue mimicking phantoms have shown the comparable imaging quality in both methods.
Źródło:
Hydroacoustics; 2012, 15; 195-206
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Foundation of the new method of numerical calculations of the nonlinear acoustics fields
Autorzy:
Wójcik, J.
Filipczyński, L.
Kujawska, T.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/332125.pdf
Data publikacji:
2004
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
We explain, motivation behind this work and briefly describe foundation of new method which we have developed for efficient solution in PC environment of the nonlinear propagation equation with the boundary conditions applied for both circular and not circular transducers (like array). Comparison between new and old method will be presented for strongly nonlinear disturbance. At the end we will demonstrate the results of the numerical calculations of the nonlinear field propagating from the array.
Źródło:
Hydroacoustics; 2004, 7; 227-234
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic ultrasonic model of left ventricle
Autorzy:
Trawiński, Z.
Wójcik, J.
Nowicki, A.
Olszewski, R.
Powiązania:
https://bibliotekanauki.pl/articles/332195.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
Two different tissue phantoms of the left ventricle to imitate a beating left ventricle were developed: first was prepared using a sponge material and second phantom was constructed using a polyvinyl alcohol material modeled into a homogeneous hollow cylinder: approximately 10 cm and 12 cm in length for the first and second phantom, respectively. Both phantoms were 5 cm in diameter, with a wall thickness of 1.0 cm. Additionally, a small part of the wall of the second phantom was processed to simulate the stiffness of myocardial infarction. The phantoms were connected at the end to an adjustable external pump. The pulse volume inside the cylinder was set between 12 to 50 ml at rates of 40, 60, 100, 120 beats/minute. The phantoms were immersed in water for ultrasound scanning with two different insonation angles (90 and 65 degrees). Strain and strain rate were measured with different combinations of angles and pulse rates. The main aim of this work was to develop the new method for validation of the human infarct wall strain calculation procedures using the speckles tracking.
Źródło:
Hydroacoustics; 2013, 16; 231-236
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies