Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kudyba, A." wg kryterium: Wszystkie pola


Wyświetlanie 1-6 z 6
Tytuł:
Effect of oxidation and mechanical damage of PCBs with OSP finish on their solderability with SAC305 alloy
Wpływ utleniania i uszkodzeń mechanicznych powierzchni płytek PCB z pokryciem OSP na ich lutowność stopem SAC305
Autorzy:
Kudyba, A.
Siewiorek, A.
Sobczak, N.
Turalska, P.
Powiązania:
https://bibliotekanauki.pl/articles/391438.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
surfaces
coatings
electronic characterization
defects
surface properties
solderability
wetting balance test
powłoki
wady
właściwości powierzchni
lutowność
badania meniskograficzne
Opis:
The paper focuses on the experimental investigation of wetting behavior and solderability of commercial lead-free solder on Printed Circuit Board (PCB) covered with an OSP finish (Organic Surface Protectant) characterized by physical (mechanically scratched) and/or chemical (oxidized in air at 260°C for 1 hour) inhomogeneity of the surface finish. The influence of the quality of the PCB finish on the maximum wetting force Fmax, wetting time t0, the contact angle θ, and the parameters characterizing solderability, were studied. The tests were performed by a wetting balance method with SAC305 solder (Sn-3.0Ag-0.5Cu, wt. %) and commercial flux (EF2200) using MENISCO ST88 apparatus allowing direct measurement of the wetting force Fr and wetting time t0 as well as calculation of the contact angle θ values. The measurements were made at a temperature of 260°C for a contact time of 3 s. For comparison, the tests were also performed on PCBs in delivery state showing average Fmax = 0.9 mN, t0 = 0.58 s and θ = 57°. The results have shown that both oxidation and mechanical damage of the OSP finish have a significant worsening effect on solderability. Scratched OSP finish had an average Fmax = -1.03 mN and θ = 78°. Such surfaces were non-wettable with corresponding values of Fmax = -4.7 mN and θ = 120° for oxidized samples and Fmax = -4.04 mN and θ = 111° for those scratched and oxidized.
W pracy badano zwilżalność i lutowność płytek drukowanych (PCB) z pokryciem OSP, które charakteryzowały się niejednorodnością występującą na powierzchni: były mechanicznie porysowane i/lub utlenione (na powietrzu, w temperaturze 260°C w czasie 1 godziny). Do badań stosowano komercyjny stop bezołowiowy. Określono wpływ jakości pokrycia na wartość maksymalnej siły zwilżania Fmax, czas zwilżania t0 i kąt zwilżania θ, czyli parametrów charakteryzujących lutowność. Badania prowadzono metodą zanurzeniową (meniskograficzną) na aparaturze ST88 MENISCO, która umożliwia bezpośredni pomiar siły zwilżania Fr i czasu zwilżania t0, jak również obliczenie wartości kąta zwilżania θ. Pomiary przeprowadzono w temperaturze 260°C w czasie 3 s. Dla porównania testy przeprowadzono również na płytkach „w stanie dostawy”, uzyskując średnią Fmax = 0.9 mN, t0 = 0,58 s i θ = 57°. Uzyskane wyniki świadczą, że zarówno utlenianie powierzchni, jak i uszkodzenia mechaniczne pokrycia OSP powodują znaczące pogorszenie lutowości płytek PCB. Dla pokrycia OSP, które było porysowane, uzyskano średnio Fmax = -1,03 mN i θ = 78°. Dla próbek utlenionych mierzone wartości wyniosły: Fmax = -4,7 mN i θ = 120°, natomiast dla próbek porysowanych i utlenionych: Fmax = -4,04 mN i θ = 111°.
Źródło:
Prace Instytutu Odlewnictwa; 2015, T. 55, nr 4, 4; 59-66
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High temperature wettability and reactivity between molten Mg in contact with Ni substrate
Wysokotemperaturowe badania zwilżalności i reaktywności ciekłego Mg w kontakcie z podłożem Ni
Autorzy:
Kudyba, A.
Sobczak, N.
Turalska, P.
Bruzda, G.
Makaya, A.
Pambaguian, L.
Powiązania:
https://bibliotekanauki.pl/articles/391589.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
sessile drop
wettability
reactivity
metal matrix composites (MMC)
kropla leżąca
zwilżalność
reaktywność
kompozyty o osnowie metalicznej (MMC)
Opis:
The paper focuses on the experimental investigation of high temperature wetting behaviour of liquid pure Mg during a contact heating on Ni substrate by the sessile drop method. High temperature wettability test was performed by the classical sessile drop method at T = 700°C for t = 300 s, under flowing Ar 99.999% atmosphere, by using the equipment and testing procedures that have been developed by the Foundry Research Institute. In order to suppress effects of heating and cooling histories on wetting and spreading behaviours, Mg/Ni couple was introduced inside a metallic heater already preheated up to the test temperature, while after the wettability test, it was immediately removed to the cold part of the chamber. During the wettability test, images of the couple were recorded by high-resolution high-speed CCD camera. It was observed, that the wetting phenomenon (θ ≤ 90°) takes place immediately after melting of Mg sample. The Mg/Ni system shows a good wetting at T = 700°C after t = 300 s forming the final contact angle of 18°.
Praca prezentuje wyniki badań wysokotemperaturowego oddziaływania ciekłego Mg w kontakcie z podłożem Ni podczas wspólnego nagrzewania badanej pary materiałów. Wysokotemperaturowe badania zwilżalności przeprowadzono klasyczna metodą kropli leżącej w temperaturze T = 700°C i czasie t = 300 s w gazie przepływowym Ar 99,999%. Do badań zastosowano aparaturę i procedury badawcze opracowane w Instytucie Odlewnictwa. W celu eliminacji wpływu historii nagrzewania i chłodzenia na zwilżalność i rozpływność, badany układ Mg/Ni wprowadzono do gorącej części komory badawczej nagrzanej do temperatury badań. Po badaniach zwilżalności badaną parę materiałów natychmiast wprowadzono do zimnej części komory badawczej. Podczas badań zwilżalności stosowano ciągłą rejestrację obrazu badanej pary materiałów za pomocą wysokorozdzielczej kamery cyfrowej CCD. Zaobserwowano, że zjawisko zwilżania (θ ≤ 90°) zachodzi natychmiast po stopieniu próbki czystego Mg. Układ Mg /Ni wykazuje bardzo dobrą zwilżalność w temperaturze T = 700° C po t = 300 s, a końcowa wartość kąta zwilżania wynosi 18°.
Źródło:
Prace Instytutu Odlewnictwa; 2018, 58, 1; 47-53
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zawartości fosforu na zwilżalność podłoży z pokryciem Ni-P lutowiem SAC305
Effect of phosphorus content on the wettability of Ni-P coated surfaces by SAC305 alloy
Autorzy:
Kudyba, A.
Sobczak, N.
Siewiorek, A.
Turalska, P.
Klasik, A.
Bieliński, J.
Sałacińska, A.
Kozera, R.
Powiązania:
https://bibliotekanauki.pl/articles/391616.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
SAC305
pokrycie Ni-P
kąt zwilżania
kinetyka zwilżania
lutowanie bezołowiowe
Ni-P coating
contact angle
wetting angle
wettability kinetics
lead-free soldering
Opis:
Celem badań było określenie wpływu składu chemicznego pokrycia Ni-P na kinetykę zwilżania ciekłego lutowia SAC305 w kontakcie z pokryciem Ni-P. Badania przeprowadzono w próżni w temperaturze 230°C w czasie 5 minut, stosując metodę kropli leżącej w połączeniu z osobnym nagrzewaniem badanej pary materiałów, pozwalającej na eksperymentalne wyznaczanie wartości kąta zwilżania θ. Do badań użyto stop lutowniczy SAC305 (3% wag. Ag, 0,5% wag. Cu, Sn – osnowa) oraz podłoża niklowe (Ni 99,8% wag.), na które naniesione zostało pokrycie Ni-xP o dwóch różnych zawartościach fosforu (x = 4,3% wag. lub 11,6% wag.). Po badaniach zwilżalności przeprowadzono analizę strukturalną powierzchni próbek metodą skaningowej mikroskopii elektronowej, koncentrując się na obserwacji granicy SAC305/podłoże. W celu określenia wpływu zawartości fosforu w pokryciu Ni-P na wytrzymałość wytworzonych połączeń SAC305/Ni-xP/Ni poprzeczne przekroje próbek poddano testom na ścinanie, stosując udoskonaloną metodę push-off shear test. Stwierdzono, że dla wybranego zakresu 4,3 ≤ P ≤ 11,6 wzrost zawartości fosforu w pokryciu poprawia zwilżalność badanych układów ciekłym lutowiem SAC305, lecz jest to efekt pozorny wynikający z penetracji lutowia w nieciągłości strukturalne powstające w warstwie Ni-11,6P na skutek przemian fazowych. Dla próbki SAC305/ Ni-11,6P/Ni wartość kąta zwilżania θ = 54° jest mniejsza w porównaniu do próbki SAC305/Ni-4,3P/Ni, dla której θ = 75°, przy tym wytrzymałość na ścinanie wytworzonych połączeń praktycznie nie ulega zmianie, wykazując dla próbki SAC305/Ni-11,6P/Ni τmax = 15,6 MPa w porównaniu τmax = 14,2 MPa dla próbki SAC305/Ni-4,3P/Ni.
The aim of this study was to determine the effect of the chemical composition of Ni-P coating on the wettability kinetics of SAC305 liquid solder in contact with the Ni-P coating. The study was conducted in vacuum, at 230°C, for 5 minutes, using the sessile drop method in combination with a separate heating of the two test materials, allowing for experimental determination of the contact angle θ. The study used a SAC305 solder (Sn base, Ag 3 wt. %, Cu 0.5 wt. %) and a nickel substrate (Ni 99.8 wt. %) onto which Ni-xP coating of two different levels of phosphorous was applied (x = 4.3 wt. %, or 11.6 wt. %). After the tests of wettability were performed, structural analysis of the surface of the samples was performed by scanning electron microscopy, focusing on the observation of the border SAC305/substrate. In order to determine the effect of phosphorus in the Ni-P coating on the strength of the SAC305/Ni-xP/Ni joints formed, cross sections of samples were tested for shear strength using the improved method of the push-off shear test. It was found that, for the selected range of 4.3 ≤ P ≤ 11.6, increase in the phosphorus content in the coating improves the wettability of the liquid systems tested with the SAC305 solder, but it is an apparent effect resulting from the solder’s penetration of the structural discontinuities formed in the layer of Ni-11.6P, due to phase transitions. For the SAC305/ Ni-11.6P/Ni sample, value of the contact angle θ = 54° is smaller, as compared to the SAC305/Ni-4.3P/Ni sample, for which θ = 75°, the shear strength of the joints produced shows virtually no changes, for the SAC305/Ni-11.6P/Ni sample τmax = 15.6 MPa, as compared to τmax = 14.2 MPa for the SAC305/Ni-4.3P/Ni sample.
Źródło:
Prace Instytutu Odlewnictwa; 2014, T. 54, nr 4, 4; 51-62
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wielkości kropli na kinetykę zwilżania w układzie SAC305/Ni
The influence of the drop-size effect on the wetting kinetics in SAC305/Ni system
Autorzy:
Turalska, P.
Sobczak, N.
Kudyba, A
Nowak, R.
Homa, M.
Siewiorek, A.
Boroń, Ł.
Klasik, A.
Powiązania:
https://bibliotekanauki.pl/articles/391805.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
kinetyka zwilżania
kąt zwilżania
lutowanie bezołowiowe
SAC305
nikiel
efekt wymiarowy kropli
wetting kinetics
contact angle
lead-free soldering
nickel
drop-size effect
Opis:
Badania wpływu efektu wymiarowego kropli na kinetykę zwilżania niklu bezołowiowym stopem na bazie cyny przeprowadzono metodą kropli leżącej w próżni w temperaturze 260°C. Do badań użyto komercyjny stop lutowniczy na bazie cyny SAC305 (Ag – 3,0% wag., Cu – 0,5% wag.) oraz wypolerowane podłoże niklowe o czystości 99,8%. Podczas testu zwilżalności stosowano osobne nagrzewanie badanej pary materiałów do temperatury badań, umieszczając próbkę stopu w kroplówce grafitowej nad powierzchnią podłoża niklowego. Po osiągnięciu wymaganej temperatury z kapilary wyciskano kroplę stopu i osadzano ją na podłożu. Po 30 sekundach wyciskano kolejną kroplę i osadzano ją na pierwszą, zwiększając tym samym objętość kropli dwukrotnie. Proces dokraplania powtarzano 9 razy co 30 sekund, osiągając 10-krotną objętość kropli w porównaniu do stanu pierwotnego. Po badaniach zwilżalności schłodzoną parę materiałów kropla/podłoże przecinano prostopadle do badanej powierzchni podłoża i poddano badaniom na ścinanie oraz analizie strukturalnej poprzecznego przekroju próbki metodami mikroskopii optycznej i skaningowej mikroskopii elektronowej w połączeniu z lokalną analizą składu chemicznego. Badania zwilżalności nie wykazały istotnych różnic wartości kąta zwilżania ciekłego stopu SAC305 na podłożu niklowym po wielokrotnym dokraplaniu, albowiem wartości kąta zwilżania każdorazowo mierzone w 30. sekundzie kontaktu z podłożem Ni były dla wszystkich 10 kropel zbliżone i wynosiły θ = 35 ±2°. Stwierdzona wysoka powtarzalność pomiarów θ świadczy zarówno o braku występowania efektu wymiarowego w badanym zakresie objętości kropli SAC305, jak i o chemicznej i fizycznej jednorodności powierzchni podłoża. Uzyskane wyniki wskazują na przydatność metody kropli leżącej do oceny jakości powierzchni, szczególnie przydatnej do badań jakości cienkich warstw i pokryć technologicznych stosowanych w procesach łączenia różnorodnych materiałów.
The studies of the drop-size effect on the wetting kinetics of the nickel substrate by lead-free solder were performed by the sessile drop method in a vacuum at a temperature of 260°C. In this work, Sn-based alloy SAC305 (Ag – 3.0 wt. %, Cu – 0.5 wt. %) and polished nickel substrate (99.8%) were used. During the wettability tests, a separate heating of the couple of materials to a test temperature was performed by placing a sample of SAC305 alloy in a graphite capillary above the nickel substrate. After reaching the test temperature, the SAC305 drop was squeezed from the capillary and deposited on the Ni substrate. After 30 seconds, the second drop was squeezed and deposited on the first one, thereby increasing the volume of the drop twice. The process was repeated 9 times every 30 seconds reaching a 10 times larger drop volume, compared to the first drop. After wettability tests, the solidified drop/substrate couple was cooled, cut and subjected to a shear test and structural analysis by optical microscopy, scanning electron microscopy and energy dispersive X-ray spectroscopy analysis. Wettability studies have not shown a significant difference between the values of the contact angle obtained for each drop produced by subsequent adding of nine drops despite their different size of ten drops produced on the substrate, their contact angle values formed after 30 second contact time were similar showing θ = 35 ±2°. High repeatability of the measured contact angle value θ demonstrates not only physical homogeneity of the substrate surface but it presents a lack of size effect over a range of SAC305 drop volume used in this study. The obtained results demonstrate the suitability of the sessile drop method for surface quality evaluation, particularly for quality tests of thin technological layers or coatings used in joining dissimilar materials.
Źródło:
Prace Instytutu Odlewnictwa; 2015, T. 55, nr 2, 2; 3-17
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wetting behavior of Si-13.5B alloy on polycrystalline h-BN-based substrates
Autorzy:
Polkowski, W.
Sobczak, N.
Nowak, R.
Kudyba, A.
Bruzda, G.
Polkowska, A.
Homa, M.
Turalska, P.
Shuleshova, O.
Kaban, I.
Powiązania:
https://bibliotekanauki.pl/articles/391820.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
silicon-boron alloys
hexagonal boron nitride
wettability
interfaces
AMADEUS Project
Opis:
In this work, for the first time the results of an experimental evaluation of the high temperature behavior of molten Si-B alloy in contact with refractory materials at temperatures up to 1750°C, under static argon atmosphere (p = 850– 900 mbar), is shown. The material investigated, having a nominal chemical composition of Si-13.5B (at. %), was fabricated by using the crucible-less electric arc-melting process assisted by the levitation drop method. The wettability of the molten alloy in contact with commercial hexagonal boron nitride (h-BN) substrates was evaluated by means of especially developed sessile drop technique combined with a contact heating procedure. It was found that both couples show a lack of wettability in the whole tested temperature range (the measured contact angle was θ > 130°). The more stable behavior in contact with molten Si-13.B alloy, evidenced by higher θ values and a lack of drop vibration during the high temperature exposition, was observed for the h-BN based composite substrate.
Źródło:
Prace Instytutu Odlewnictwa; 2017, 57, 4; 321-326
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Termofizyczne właściwości kompozytów Ag-C domieszkowanych nanorurkami węglowymi
Thermophysical properties of Ag-C composites doped with carbon nanotubes
Autorzy:
Homa, M.
Siewiorek, A.
Gazda, A.
Sobczak, N.
Kudyba, A.
Turalska, P.
Pietrzak, K.
Frydman, K.
Wójcik-Grzybek, D.
Strojny-Nędza, A.
Powiązania:
https://bibliotekanauki.pl/articles/391446.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
kompozyty Ag-C
nanorurki węglowe
właściwości termofizyczne
Ag-C composites
carbon nanotuvbes
thermophysical properties
Opis:
Praca prezentuje wyniki wstępnych badań materiałów typu Ag-C otrzymanych metodą metalurgii proszków (PM) domieszkowanych nanorurkami węglowymi. Na podstawie przeprowadzonych metodami skaningowej mikroskopii elektronowej badań strukturalnych oraz wykonanych badań właściwości termofizycznych metodami DSC, DIL, LFA stwierdzono, że zastosowana procedura wytwarzania materiałów kompozytowych nie zapewnia zadawalającego rozmieszczenia fazy węglowej w osnowie metalowej. W celu uzyskania poprawy jednorodności materiałów typu Ag-C należy opracować sposób deaglomeracji fazy węglowej.
The paper presents results of preliminary studies on Ag-C materials obtained using the powder metallurgy (PM) method with carbon nanotube doping. Based on structural tests performed using scanning electron microscopy and DSC, DIL and LFA tests of thermophysical properties, it was ascertained that the utilised procedure of producing composite material does not ensure satisfactory distribution of the carbon phase in the metal matrix. In order to improve the uniformity of Ag-C materials, a new method of deagglomerating the carbon phase needs to be developed.
Źródło:
Prace Instytutu Odlewnictwa; 2014, T. 54, nr 1, 1; 13-24
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies