Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "för, R." wg kryterium: Wszystkie pola


Tytuł:
Optimization measurement method for checkweigher
Autorzy:
Ugodziński, R.
Kamiński, M.
Nowicki, M.
Szewczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/114697.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
checkweigher
optimization
weighing methods
filter
Opis:
Abstract: The paper presents a new measurement method for checkweighers, where the measurement result is obtained by solving a simple optimization problem. The method assumes that the mass of constant geometry and a small masses spread is measured. The measurement accuracy changes as a function of noise-eliminating low-pass filter frequency was investigated. The state of knowledge about the filtration of checkweigher signal is also summarized.
Źródło:
Measurement Automation Monitoring; 2015, 61, 2; 39-42
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of magnetovision for detection of dangerous objects
Autorzy:
Nowicki, M.
Szewczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/385177.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
magnetovision
magnetoresistive sensors
magnetic imaging
Opis:
Paper presents application of magnetovision in weak magnetic fields for public security systems. Measurement system was developed to study the magnetic field vector distributions. The measurements of the Earth’s field disturbances caused by ferromagnetic objects were carried out. The ability for passive detection of selected dangerous objects and determine their location was demonstrated.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2013, 7, 2; 70-74
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Capacitive human presence sensor for safety applications
Autorzy:
Frydrych, A.
Szewczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/384375.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
capacitive sensors
people safety
underground transportation network
Opis:
Paper presents a novel idea of capacitive sensor for human presence detection. Due to the use of resonant circuit significant increase of sensor's sensitivity was achieved. In the case of human hand, value of output signal changes up to 421per cent. Moreover, sensor creates possibility of determination of the material of the detected object. As a result developed sensor can be applied for human presence detection sensors utilized in safety systems, which are especially suitable for underground transportation network.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2010, 4, 3; 45-49
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetovision Scanning System for Detection of Dangerous Objects
Autorzy:
Nowicki, M.
Szewczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/1202312.pdf
Data publikacji:
2014-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
81.70.-q
85.75.Ss
Opis:
This paper presents an application of magnetovision based measurements to develop a method for passive detection of dangerous ferromagnetic objects. Scanning system was designed and built to study the magnetic field vector distributions. The measurements of the Earth's field disturbances caused by ferromagnetic objects were carried out. The ability for passive detection of selected dangerous objects was demonstrated. Further data processing allowed for determining the (x,y) coordinates of the object relative to the plane of measurement, and even the possibility of calculating the distance from the object. The results obtained indicate that it is possible to detect and determine the location of dangerous ferromagnetic objects. This opens the new way to use magnetovision in public security systems, in particular for the detection of dangerous objects by police and sapper robots.
Źródło:
Acta Physica Polonica A; 2014, 126, 1; 382-383
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PI control of laboratory furnace for annealing of amorphous alloys cores
Autorzy:
Kurek, J. E.
Szewczyk, R.
Salach, J.
Kloda, R.
Powiązania:
https://bibliotekanauki.pl/articles/384934.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
PI controller
resistive furnace
temperature control
Opis:
There are presented theoretical and practical aspects of automatic control of resistive furnace for thermal annealing of magnetic cores made of amorphous alloys. Process of annealing requires specific conditions both from the point of view of temperature and its changes. Solutions presented in the paper create possibility for low value of error as well as fast achievement of set value.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2012, 6, 4; 13-15
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High Resolution Eddy Current Tomography System for Nondestructive Testing
Autorzy:
Salach, J.
Szewczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/1202343.pdf
Data publikacji:
2014-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
81.70.Ex
81.70.Tx
Opis:
Idea of the high-resolution eddy current tomography is presented. Proposed system gives possibility of testing cylinder-shaped elements made of both magnetic and non-magnetic materials. To validate the concept, the tomographic measurements are carried out on set of steel cylinders with non-magnetic copper inclusion. Measurements were done during both linear and rotational movement of the element. Achieved results indicate the high sensitivity of system, which creates possibility of its application for non-destructive testing of the elements made of ferromagnetic and non-magnetic materials.
Źródło:
Acta Physica Polonica A; 2014, 126, 1; 402-403
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Extension of the Jiles-Atherton Model for Modelling the Frequency Dependence of Magnetic Characteristics of Amorphous Alloy Cores for Inductive Components of Electronic Devices
Autorzy:
Szewczyk, R.
Frydrych, P.
Powiązania:
https://bibliotekanauki.pl/articles/1507194.pdf
Data publikacji:
2010-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.50.Kj
75.60.Ej
75.78.-n
Opis:
The paper presents the results of modelling the influence of magnetizing field frequency on the magnetic characteristics of $Fe_{40}Ni_{38}Mo_4B_{18}$ amorphous alloy in as-quenched state. An extension for the Jiles-Atherton model was applied and changes of the parameter k during the magnetization process were considered. On the base of the experiment, the parameters of the Jiles-Atherton model were calculated for experimental hysteresis loop. Evolutionary strategies, together with the gradient optimisation method, were used. Moreover, the changes of parameters c and a as the function of frequency of magnetizing field were also taken into consideration. Finally, the high conformity between the experimental and modelling results was achieved. This high conformity indicates that the results both create new possibilities in modelling of properties of inductive components based on the amorphous alloys, as well as extend the possibility of quantitative description of magnetization process.
Źródło:
Acta Physica Polonica A; 2010, 118, 5; 782-784
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Generalization of Magnetostatic Method of Moments for Thin Layers with Regular Rectangular Grids
Autorzy:
Szewczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/1032670.pdf
Data publikacji:
2017-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.70.Ak
75.50.Kj
Opis:
Possibilities of the modeling of the flux density distribution in thin films are significantly limited using the finite elements method due to the fast increase of the number of tetrahedral elementary cells with reduction of the thickness. For this reason, method of the moments is very important alternative for finite elements method in the case of thin layers, where layer's thickness should be considered. Method of the moments overcomes this barrier, due to the possibility of operation on uniform grids with limited number of cells. Moreover, in opposite to the finite elements method, the method of the moments requires solving of the well defined linear equations, instead of the set of ill-posed differential equations. Paper presents the generalization of the method of the moments for thin layers with given thickness. Layers are defined as the 2D rectangular grids. Within the generalization, four key equations describing the influence of rectangular cell's border on the magnetization of cells are stated. On the base of these dependences, the set of 2NM linear equations was determined, where N and M are the numbers of rectangular cells in the rows and columns of regular grid. Finally, the set of linear equations is solved and magnetic flux density distribution in the thin layer is calculated.
Źródło:
Acta Physica Polonica A; 2017, 131, 4; 845-847
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utilization of Electromagnetic Tomography for Ferrite Rings Testing
Autorzy:
Nowak, P.
Nowicki, M.
Gromada, K.
Szewczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/1030849.pdf
Data publikacji:
2018-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
85.80.Jm
87.10.Kn
Opis:
Paper presents utilized innovative setup for eddy current tomography and possibility of its utilization in testing oxide materials such as ferrites. Previously reported tests concerned materials with high conductivity which is the most typical usage of eddy current tests. Described tomography setup is designed for testing axisymmetric objects thus typical ferrite ring was selected for exemplary testing. Tests were conducted on ring in original state. Afterwards reference defect was created on element and measurements were repeated. Significant difference between tests results were observed, thus potential for utilization in controlling of ferrite rings manufacturing process was confirmed. Finite element method simulations were applied in order to confirm the measurement results. Calculations were conducted in open-source finite element method software, which solves the Maxwell equations in the A-V form. Modelling results confirm possibility of finite element method-based inverse tomography transformation.
Źródło:
Acta Physica Polonica A; 2018, 133, 4; 1045-1048
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical B-H Saturation Magnetization Curve Models for SPICE, FEM and MoM Simulations
Autorzy:
Szewczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/384253.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
saturation
magnetization curve
perpendicular anisotropy
Mn-Zn ferrite
Finemet
Opis:
Recent development of SPICE, FEM and MoM software often requires the fast and reliable description of BH saturation magnetization curve. In spite of the fact that physical models of BH saturation curve are very sophisticated, for technical purposes, such curve may be modelled by simplified equations. Paper presents the quantitative assessment of the quality of four technical models of BH saturation magnetization curve performed for four modern magnetic materials: constructional corrosion resistant steel, Mn-Zn ferrite, amorphous alloy with perpendicular anisotropy as well as Finemet-type nanocrystalline magnetic material. Presented results confirm reliability of the model as well as indicate that high-speed calculation may be done using arctangent function.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2016, 10, 2; 3-7
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing of the three axis magnetometers for measurements of the earths magnetic field
Autorzy:
Szewczyk, R.
Salach, J.
Bieńkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/385198.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
magnetic sensors
Helmholtz coils
calibration
Opis:
The paper presents experimental setup for testing of the three axis magnetoresisitive magnetometers for measurements of the magnetic field within the range of Earth's magnetic field. Measuring setup integrates three axis Helmholtz coils controlled by the specialized current source. The accuracy of magnetic field generated by the Helmholtz coils is up to 0.6% for the one direction. Presented experimental setup can be also applied for investigation and calibration of the other magnetometers utilizing magnetoresistive, Hall or fluxgate sensors.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 96-98
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of the Magnetic Characteristics of Isotropic and Anisotropic Materials for Sensor Applications
Autorzy:
Szewczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/1813527.pdf
Data publikacji:
2008-01
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.60.Ej
75.50.Gg
75.50.Kj
Opis:
The following paper presents the results of modelling of the magnetic characteristics of isotropic (Ni-Zn ferrite) and anisotropic material ($Fe_{40}Ni_{38}Mo_4B_{18}$ amorphous alloy in as quenched state), both useful for sensor applications. For the modelling an extended Jiles-Atherton model was used. Extension of the model connects model's parameter k, describing average energy required to break pinning site, with magnetic state of the material. Such extension of the model is reasonable from the physical point of view. Good agreement between experimental data and modelling confirms that the extended Jiles-Atherton model creates the possibility of modelling of magnetic characteristics of both isotropic and anisotropic magnetic cores.
Źródło:
Acta Physica Polonica A; 2008, 113, 1; 67-70
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the industrial automation standards and methodologies for reliable and continuous European food traceability system
Autorzy:
Szewczyk, R.
Rzeplińska, K.
Winiarski, W.
Powiązania:
https://bibliotekanauki.pl/articles/384242.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
food traceability
telemetry
Opis:
Recent traceability requirements create necessity of organization of the food production process in the completely new way. This way of production organization is typical rather for large industry, than for traditional way of work at the rural areas. This fact generates tensions as well as resistance of the farmers, especially farmers working in traditional way. This paper presents new ideas of industrial application of automation standards and methodologies for reliable, robust and user-friendly food traceability system. Due to the high level of automation and application of industrial IT solutions together with multimodal data transmission, presented traceability system can be implemented in traditional food production farms and operated intuitively by personnel without specialized training. As a result application of presented system will signifi-cantly reduce tensions and resistance connected with implementation of new technologies in tradi-tional food production farms.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2008, 2, 3; 55-57
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic Measurement Station for Ferrite Materials Testing
Autorzy:
Charubin, T.
Nowak, P.
Nowicki, M.
Szewczyk, R.
Urbański, M.
Powiązania:
https://bibliotekanauki.pl/articles/1031017.pdf
Data publikacji:
2018-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.60.Ej
75.47.Lx
52.70.Ds
Opis:
The paper presents automatic and modular measurement station for the magnetic materials testing. It allows for measurements of magnetic hysteresis loops under various regimes (sine, triangle or arbitrary magnetizing field, sine or triangle magnetic flux density) and relative permeability curves. The modular nature of the system allows for measurements of magnetic parameters under additional external influences, such as temperature and stress. The system is currently used for measurements of ferrite materials parameters.
Źródło:
Acta Physica Polonica A; 2018, 133, 4; 1049-1052
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mobile ferrograph system for ultrahigh permeability alloys
Autorzy:
Charubin, T.
Nowicki, M.
Marusenkov, A.
Szewczyk, R.
Nosenko, A.
Kyrylchuk, V.
Powiązania:
https://bibliotekanauki.pl/articles/384845.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
ferrograph
hysteresis
amorphous alloys
mobile measurement system
Opis:
This paper presents a mobile ferrograph system for measurement of magnetic parameters of ultrahigh permeability alloys. The structure of developed system is described, as well as exemplary measurement results of Co67Fe3Cr3B12Si15 alloy used in space applications are presented.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2018, 12, 3; 40-42
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies