Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Zoladz, M." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
64 Channel ASIC for Neurobiology Experiments
Autorzy:
Gryboś, P.
Kmon, P.
Szczygieł, R.
Żołądź, M.
Powiązania:
https://bibliotekanauki.pl/articles/226849.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
low noise amplifier
neural recording
ASIC
multichannel systems
neurobiology experiments
Opis:
This paper presents the design and measurements of 64 channel Application Specific Integrated Circuits (ASIC) for recording signals in neurobiology experiments. The ASIC is designed in 180 nm technology and operates with ± 0.9 V supply voltage. Single readout channel is built of AC coupling circuit at the input and two amplifier stages. In order to reduce the number of output lines, the 64 analogue signals from readout channels are multiplexed to a single output by an analogue multiplexer. The gain of the single channel can be set either to 350 V/V or 700 V/V. The low and the high cut-off frequencies can be tuned in 9 ÷ 90 Hz and in the 1.6 ÷ 24 kHz range respectively. The input referred noise is 7 µV rms in the bandwidth 90 Hz - 1.6 kHz and 9 µ V rms in the bandwidth 9 Hz - 24 kHz. The single channel consumes 200 µW of power and this together with other parameters make the chip suitable for recording neurobiology signals.
Źródło:
International Journal of Electronics and Telecommunications; 2010, 56, 4; 375-380
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
64 channel neural recording amplifier with tunable bandwidth in 180 nm CMOS technology
Autorzy:
Gryboś, P.
Kmon, P.
Żołądź, M.
Szczygieł, R.
Kachel, M.
Lewandowski, M.
Błasiak, T.
Powiązania:
https://bibliotekanauki.pl/articles/220527.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
neurobiological measurements
low noise amplifier
neural recording
band-pass filter
multichannel ASIC
Opis:
This paper presents the design and measurements of low-noise multichannel front-end electronics for recording extra-cellular neuronal signals using microelectrode arrays. The integrated circuit contains 64 readout channels and is fabricated in CMOS 180 nm technology. A single readout channel is built of an AC coupling circuit at the input, a low-noise preamplifier, a band-pass filter and a second amplifier. In order to reduce the number of output lines, the 64 analog signals from readout channels are multiplexed to a single output by an analog multiplexer. The chip is optimized for low noise and good matching performance and has the possibility of passband tuning. The low cut-off frequency can be tuned in the 1 Hz - 60 Hz range while the high cut-off frequency can be tuned in the 3.5 kHz - 15 kHz range. For the nominal gain setting at 44 dB and power dissipation per single channel of 220 žW, the equivalent input noise is in the range from 6 žV - 11 žV rms depending on the band-pass filter settings. The chip has good uniformity concerning the spread of its electrical parameters from channel to channel. The spread of the gain calculated as standard deviation to mean value is about 4.4% and the spread of the low cut-off frequency set at 1.6 Hz is only 0.07 Hz. The chip occupies 5×2.3 mm⊃2 of silicon area. To our knowledge, our solution is the first reported multichannel recording system which allows to set in each recording channel the low cut-off frequency within a single Hz with a small spread of this parameter from channel to channel. The first recordings of action potentials from the thalamus of the rat under urethane anesthesia are presented.
Źródło:
Metrology and Measurement Systems; 2011, 18, 4; 631-643
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies