Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "hydraulic flow system" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Model testing of the internal leaks of valve body in automatic transmission
Autorzy:
Dziubak, T.
Szczepaniak, P.
Powiązania:
https://bibliotekanauki.pl/articles/246026.pdf
Data publikacji:
2017
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
automatic transmission
hydraulic system
hydraulic precise pair
wear of hydraulic couplings
internal leaks
ATF fluid flow rate model
Opis:
The article presents the working conditions and the functions of the ATF fluid in an automatic transmission. It was noted that the correct operation of the automatic transmission is heavily influenced by the quality of the ATF fluid, which operates in disadvantageous conditions of oxidising environment, is subject to contamination and undergoes intense shearing, thus changing its physical and chemical properties during use. The analysis included the disadvantageous, from the point of view of loss of fluid pressure in the automatic transmission’s hydraulic system, phenomenon of the fluid’s flow through fractures (clearances) of the hydraulic precise pairs “called the rate of flow through internal leaks” or an “internal leak”. The model of the rate of flow through internal leaks was proposed to determine the impact of the precise pairs’ wear and the hydraulic fluid’s properties on the aggregated leaks in the hydraulic system controller of the automatic transmission. The modelling utilised the dependency between the rate of flow through internal leaks of the hydraulic precise pair and the coaxial circular fracture. The model’s assumptions were formulated. The values of clearances of the electrohydraulic controller’s precise pairs were determined during the measurements of the actual structure – based on the automatic transmission’s mileage. The measurements featured relevant diameters of pushers and sliders, as well as internal diameters of cylindrical openings of manifold sliders and hydraulic suppressors. Variant model testing was conducted with various degrees of the fluid’s wear and temperature (viscosity and density) for conditions of driving with transmission “1” and “2”.
Źródło:
Journal of KONES; 2017, 24, 3; 71-78
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model of the rate of flow of hydraulic fluid leaking through precision pairs in the electrohydraulic controller of an automatic transmission
Model natężenia przepływu płynu hydraulicznego przez nieszczelności par precyzyjnych sterownika elektrohydraulicznego automatycznej skrzyni biegów
Autorzy:
Dziubak, T.
Szczepaniak, P.
Powiązania:
https://bibliotekanauki.pl/articles/1363490.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz. Przemysłowy Instytut Motoryzacji
Tematy:
automatic transmissions (AT)
hydraulic system
electro-hydraulic controller
precision hydraulic pair
internal leakage
ATF flow rate
automatyczne skrzynie biegów (ASB)
układ hydrauliczny
sterownik elektrohydrauliczny
hydrauliczna para precyzyjna
nieszczelności wewnętrzne
model natężenia przepływu płynu ATF
Opis:
The conditions of operation and functions of automatic transmission fluid (ATF) in the automatic transmission (AT) have been presented. It has been shown that the ATF quality has a significant impact on the correct functioning of an electrohydraulic AT controller. The phenomenon of ATF flow through gaps (clearance) in precision hydraulic pairs, referred to as “internal leakage” and characterized by “internal leakage rate”, has been analysed. It has been shown that excessive “internal leakage”, caused by excessive wear of hydraulic parts and low oil viscosity, may result in a fluid pressure drop in the AT hydraulic system and in incorrect functioning of the transmission unit. A model of the rate of internal leakage of hydraulic fluid through precision pairs in distribution valves has been proposed. In the model, an equation has been used that defines the rate of internal leakage in a precision hydraulic pair with a concentric annular gap. The model assumptions adopted and the test conditions have been specified. The values of clearance between components of the precision pairs in the electrohydraulic controller were determined by measurements carried out on a real controller that had been normally operated for quite a long time. The related outer diameters of pistons and spools and inner diameters of spool valve sleeves and hydraulic dampers were measured. Multi-variant tests were carried out on the model, with determining the total leakage values for the AT hydraulic system controller with different values of the degree of wear of the precision pairs and at different values of fluid temperature (viscosity and density) for the conditions of vehicle drive in gears “1” and “2”.
Przedstawiono warunki pracy oraz funkcje płynu ATF w automatycznej skrzyni biegów (ASB). Wykazano, że istotny wpływ na prawidłową pracę sterownika elektrohydraulicznego ASB ma jakość płynu ATF. Przeanalizowano zjawisko przepływu płynu ATF przez szczeliny (luzy) hydraulicznych par precyzyjnych „nazywane natężeniem przepływu nieszczelności wewnętrznej” lub „przeciekiem wewnętrznym”. Wykazano, że nadmierne „przecieki wewnętrzne”, spowodowane nadmiernym zużyciem elementów hydraulicznych i niską lepkością oleju, mogą być powodem spadku ciśnienia płynu w układzie hydraulicznym ASB i przyczyną jej nieprawidłowego jej działania. Zaproponowano model natężenia przepływu przez nieszczelności wewnętrzne hydraulicznych par precyzyjnych elementów rozdzielczych. Wykorzystano zależność na natężenie przepływu przez nieszczelności wewnętrzne hydraulicznej pary precyzyjnej ze szczeliną pierścieniową koncentryczną. Sformułowano założenia modelu i warunki badań. Wartości luzów par precyzyjnych sterownika elektrohydraulicznego określono podczas pomiarów na obiekcie rzeczywistym - po przebiegu eksploatacyjnym ASB. Pomierzono odpowiednie średnice tłoczków i suwaków oraz średnic wewnętrznych otworów cylindrycznych suwaków rozdzielczych i tłumików hydraulicznych. Przeprowadzono wariantowe badania modelu określając sumaryczne przecieki sterownika układu hydraulicznego ASB z różnymi wartościami stopnia zużycia par precyzyjnych i temperatury (lepkości i gęstości) płynu dla warunków jazdy na przełożeniu „1” i „2”.
Źródło:
Archiwum Motoryzacji; 2017, 78, 4; 43-61
1234-754X
2084-476X
Pojawia się w:
Archiwum Motoryzacji
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies