Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wiecek, B." wg kryterium: Autor


Wyświetlanie 1-8 z 8
Tytuł:
A simplified model of parasitic radiation in IR bolometer camera
Autorzy:
Strąkowski, R.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/973071.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
radiation model
configuration factor
uncooled camera
residual non uniformity
heat exchange
Opis:
This article presents the impact of thermal radiation of the internal elements of the camera on temperature and its distribution on the bolometers of the Focal Plane Array. In order to estimate the effect of this component, a simplified radiation heat transfer model was created for the detector, the object and the camera housing. The model is based on the known term of radiation configuration factors. It was also suggested to use a radiation screen to isolate the detector from the influence of the camera housing. Finally, results of numerical simulations for different camera work conditions are presented.
Źródło:
Measurement Automation Monitoring; 2017, 63, 3; 94-97
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metrologiczna kamera termowizyjna z detektorem mikrobolometrycznym VOx
Metrological thermovision camera with VOx microbolometer
Autorzy:
Strąkowski, R.
Strąkowska, M.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/154583.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termowizja
budowa kamery termowizyjnej
korekcja niejednorodności
thermovision
infrared camera construction
nonuniformity correction
Opis:
W artykule opisano budowę kamery termowizyjnej zaprojektowanej i wykonanej w Instytucie Elektroniki Politechniki Łódzkiej. Opisano blokowy schemat układu elektronicznego współczesnej kamery termowizyjnej. Omówiono proces akwizycji i korekcji obrazu termowizyjnego podczas jego transmisji na całej długości toru transmisyjnego kamery, od detektora do komputera. Przedstawiono operacje wykonywane na sygnale analogowym w układzie odczytu detektora oraz metody cyfrowej korekcji termogramu w czasie rzeczywistym zaimplementowane w procesorze sygnałowym.
In this paper construction of a new thermovision camera together with its parameters are presented. The camera was designed and realized in the Institute of Electronics at Technical University of Lodz. At first, the block diagram of a modern infrared camera was analyzed. It was divided into two parts: detectors and control-processing sections. First section, apart from VOx detector, contained also analog power suppliers, a focal plane array temperature stabilization circuit and a digital to analog converter. The second section consisted of a digital signal processor, SRAM and nonvolatile memories, a programmable logic device and the Ethernet interface for image transmission. The overall logic was implemented in a CPLD device for controlling the VOx detector. The image acquisition and correction processes along the whole transmission path are presented. Real time non-uniformity and bad pixel corrections performed by a powerful digital signal processor are described. Finally, the calibration process existing for every metrological camera and conclusions are given.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 10, 10; 1104-1107
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie termowizji w badaniach przesiewowych na przykładzie zmian nowotworowych piersi
Application of thermovision in screening examinations on the example of breast carcinoma
Autorzy:
Więcek, M.
Strąkowski, R.
Jakubowska, T.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/261726.pdf
Data publikacji:
2010
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
termowizja
sieci neuronowe
nowotwór
tumour
thermovision
neural networks
Opis:
W pracy przedstawiono procedurę termowizyjnych badań przesiewowych, w których dokonano selekcji oraz klasyfikacji obrazów za pomocą sieci neuronowych. Metodę zastosowano do badań zmian nowotworowych piersi. Sieć nauczono za pomocą 15 termogramów obrazujących zmiany patologiczne i 15 termogramów z grupy kontrolnej w projekcji przedniej i bocznej. Dodatkowo zastosowano analizę różnicy cech piersi zdrowej i chorej, co zapewniło największą skuteczność klasyfikacji na poziomie 70%. Lepsze wyniki klasyfikacji uzależnione są od wielkości zbioru uczącego.
In this work, the procedure of screening breast pathology based on thermovision examinations was presented. The thermal image features were evaluated and classified by means of neural networks. 15 thermal images representing pathological lesions and 15 images from control group were examined, both from fivntal and side positions of a patient. In addition, the differences of features of neoplastic and healthy breasts tissue, were evaluated. The classification efficiency up to 70% was achieved. The better classification can be obtained in case of bigger number of thermal images from both groups: pathological and control ones.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2010, 16, 1; 49-55
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Perfusion and Thermal Parameters of Skin Tissue Using Cold Provocation and Thermographic Measurements
Autorzy:
Strąkowska, M.
Strąkowski, R.
Strzelecki, M.
De Mey, G.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/220811.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active thermovision
perfusion
thermal model
skin tissue
measurement uncertainty
Opis:
Measurement of the perfusion coefficient and thermal parameters of skin tissue using dynamic thermography is presented in this paper. A novel approach based on cold provocation and thermal modelling of skin tissue is presented. The measurement was performed on a person’s forearm using a special cooling device equipped with the Peltier module. The proposed method first cools the skin, and then measures the changes of its temperature matching the measurement results with a heat transfer model to estimate the skin perfusion and other thermal parameters. In order to assess correctness of the proposed approach, the uncertainty analysis was performed.
Źródło:
Metrology and Measurement Systems; 2016, 23, 3; 373-381
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multispektralny system pomiarowy do określenia parametrów żużla stalowniczego podczas spustu stali z pieca hutniczego do kadzi odlewniczej
Multispectral measuring system for determination of steel slag parameters during steel tapping from metallurgical furnace to casting ladle
Autorzy:
Wittchen, W.
Borecki, M.
Więcek, B.
Pacholski, K.
Olbrycht, R.
Strąkowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/181675.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Metalurgii Żelaza im. Stanisława Staszica
Tematy:
żużel stalowniczy
współczynnik emisyjności
termowizja
sieci neuronowe
system wielospektralny
steel slag
emission factor
thermovision
neural networks
multispectral system
Opis:
Przedstawiono wyniki projektu badawczego, o charakterze interdyscyplinarnym, dotyczącego opracowania metody oraz wielospektralnego systemu pomiarowego do oceny zawartości tlenku żelaza w żużlu stalowniczym, podczas spustu stali z pieca hutniczego do kadzi odlewniczej. Parametr ten ma istotne znaczenie w procesie dalszego wytwarzania stali. Realizowany projekt oparty był na założeniu, że na podstawie charakterystyk promieniowania żużla podczas spustu stali z pieca do kadzi, rozkładu temperatury wzdłuż strugi oraz innych parametrów procesu metalurgicznego można ocenić zawartość tlenku żelaza (FeO) w żużlu stalowniczym. Do realizacji tego celu zaproponowano między innymi wykorzystanie kamer termowizyjnych, które coraz częściej są instalowane w wielu zakładach metalurgicznych do detekcji żużla podczas spustu stali. W ramach projektu opracowano metodykę oraz oprogramowanie komputerowe pozwalające na wyznaczanie parametrów promieniowania, które wraz z emisyjnością charakteryzują żużel stalowniczy. Wartości tych parametrów wyznaczane były za pomocą obróbki statystycznej obrazów strugi stali i żużla przy użyciu wielospektralnego systemu pomiarowego wykorzystującego dwie kamery termowizyjne (średniofalową i długofalową) w zakresie promieniowania podczerwonego oraz aparatu RGB dokonującego rejestracji obrazów w paśmie światła widzialnego. Do klasyfikacji i aproksymacji danych pomiarowych są wykorzystywane sztuczne sieci neuronowe, gdzie wartość wyjściowa odpowiada zawartości tlenku żelaza w żużlu stalowniczym, pojawiającym się podczas spustu stali z pieca hutniczego do kadzi.
This article presents results of the multidisciplinary research project for development of the method and multispectral measuring system for evaluation of ferric oxide content in steel slag during steel tapping from metallurgical furnace to casting ladle. This parameter is essential during further steelmaking process. The project relied on the assumption that ferric oxide (FeO) content in steel slag could be evaluated on the basis of slag radiation characteristics during steel tapping from furnace to ladle, temperature distribution along the stream and other metallurgical process parameters. To accomplish this objective, it was proposed, among other things, to use thermal cameras, which are more and more often installed in many metallurgical plants for slag detection during steel tapping. Under the project, the methodology and computer software were developed to allow the determination of radiation parameters, which, together with emissivity, characterise steel slag. The values of these parameters were determined by static treatment of steel and slag stream images using the multispectral measuring system with two infrared radiation thermal cameras (medium- and long-wave) and the RGB device to record images in the visible light band. For classification and approximation of measuring data the artificial neural networks are used where the initial value corresponds to ferric oxide content in steel slag that occurs during steel tapping from metallurgical furnace to ladle.
Źródło:
Prace Instytutu Metalurgii Żelaza; 2015, T. 67, nr 2, 2; 168-174
0137-9941
Pojawia się w:
Prace Instytutu Metalurgii Żelaza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Program do wyznaczania statystycznych cech promiennych żużla stalowniczego
Software for steel slag statistical analysis
Autorzy:
Strąkowski, R.
Pacholski, K.
Więcek, B.
Olbrycht, R.
Wittchen, W.
Borecki, M.
Powiązania:
https://bibliotekanauki.pl/articles/155771.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
żużel stalowniczy
emisyjność
termowizja
system wielospektralny
steel slag
emissivity
thermography
multispectral system
Opis:
W artykule opisano oprogramowanie pozwalające na wyznaczenie promiennych parametrów statystycznych, które wraz z emisyjnością charakteryzują skład chemiczny żużla stalowniczego pojawiającego się podczas spustu stali z pieca hutniczego. Wartości tych parametrów wyznaczane są za pomocą obróbki statystycznej obrazów strugi rejestrowanych podczas spustu stali za pomocą wielospektralnego komputerowego systemu pomiarowego wykorzystującego dwie kamery termowizyjne (średnio i długofalową) oraz cyfrowy aparat fotograficzny rejestrujący zdjęcia w pasmie światła widzialnego.
The authors have applied thermovision in iron and steel industry, where basing on the analysis of the recorded sequence of thermograms it is possible to estimate the FeO content in the slag during the process of steel discharge from a converter to a ladle. Not only mid and long wavelength infrared cameras are required for this purpose but also appropriate software dedicated for analysis of the recorded thermal images. This paper describes such a software (Figs. 3, 4) created especially for this purpose, enabling qualitative and quantitative analysis of FeO content in the slag. The software enables determination of radiative statistical parameters that (alongside with emissivity) characterize chemical ingredients of the steel slag discharged from the converter with molten steel. The values of the above mentioned parameters are determined by the statistical analysis of thermograms recorded with a multispectral computer measurement system containing two thermal cameras and one vision-range camera. This analysis is performed with the developed algorithms (Fig. 5) using neural network approach (Fig. 6). The obtained results are promising as the software managed to properly asses the FeO content in 27 test cases (Fig. 7).
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 9, 9; 985-988
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ilościowe aspekty zastosowania termowizji w podczerwieni w hutnictwie
Qualitative aspects of thermal vision applications in steelworks
Autorzy:
Wittchen, W.
Borecki, M.
Więcek, B.
Pacholski, K.
Olbrycht, R.
Strąkowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/155931.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termowizja
termografia
podczerwień
badania nieniszczące
hutnictwo
thermovision
thermography
infrared
non-invasive research
steelworks
Opis:
Przedstawiono możliwości wykorzystania techniki termowizyjnej w hutnictwie żelaza i stali jako bezinwazyjną metodę pomiarową służącą do badania rozkładu pola temperaturowego na zewnętrznej powierzchni monitorowanego obiektu. Zaprezentowano wybrane przykłady wykorzystania kamery termowizyjnej w aplikacjach hutniczych jako narzędzia umożliwiającego kontrolę stanu termalnego urządzeń oraz ostrzegania przed awariami jak również badanie procesów technologicznych. Podkreślono nieinwazyjny charakter badań.
Thermovision has a wide range of applications in iron and steel industry, where on the basis of the obtained results, researches and analysis, it is possible to evaluate the thermal state of a device, to control the production cycle, to verify technological procedures and to support processes of physical and numerical simulation. With using an infrared camera and appropriate software dedicated for the analysis of thermal images, we have the possibility to detect spots with the lowest and highest temperature on the surface of the examined object and determining the real-time temperature distrbution along a specified line, area or point. This method allows creating a qualitative and quantitative analysis. Considering the fact, that in the iron and steel metallurgy many processes consisting of great heat removal are realized, thermovision plays an important role in control of the state of devices and technological processes. In many cases, infrared cameras or scanners are installed on the production lines in order to monitor the production cycle e.g. systems of slag detection during draining steel from a metallurgical furnace to a ladle or infrared scanners used during the plate rolling process, where maintaining the temperature in a given scope is obligatory. The presented problems do not cover all possibilities of thermovision technique in iron and steel metallurgy; they only show selected aspects and examples of its typical applications.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 9, 9; 916-919
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Importance of radiative heat transfer for infrared thermography measurements
Znaczenie radiacyjnej wymiany ciepła w pomiarach termowizyjnych
Autorzy:
De Mey, G.
Więcek, B.
Kałuża, M.
Olbrycht, R.
Strąkowski, R.
Strąkowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/154589.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
radiacyjna wymiana ciepła
termografia
promieniowanie podczerwone
heat transfer by radiation
thermography
infrared radiation
Opis:
The basics of heat transfer by radiation will be shortly outlined: Planck's law, Stefan Boltzmann's law, emissivity, construction of a black body, effective emissivity, reflection. Several applications for infrared thermography, basic physical principles of microbolometer detector, non uniformity correction without shutter and blocking the image and some original experiments will be discussed afterwards. The main conclusion of this work is that calibration of metrological cameras has to be performed for different temperature of their housing.
W artykule przedstawiono podstawy wymiany ciepła przez radiację: prawo Plancka, Stefana Boltzmanna, emisyjność materiałów, budowę ciała doskonale czarnego, efektywną emisyjność oraz prawo odbicia. Omówiono również niektóre aplikacje w termografii w podczerwieni, w których wykorzystuje się efekty radiacyjne. Omówiono fizyczne podstawy działania detektora mikrobolometrycznego, korekcję niejednorodności matrycy bolometrycznej bez migawki i blokowania obrazu oraz wybrane oryginalne eksperymenty. Przedstawiono wpływ promieniowania obudowy na działanie detektora i kamery termowizyjnej oraz zastosowanie pierścieni pośrednich w badaniach termowizyjnych.Niestety obudowa i pierścienie emitują pasożytnicze promieniowanie, które musi być uwzględnione w pomiarach termowizyjnych. Wnioskiem z pracy jest stwierdzenie, że w metrologicznej kamerze termowizyjnej, kalibracja powinna być przeprowadzona dla różnych wartości temperatury obudowy. Mówimy wówczas o korekcji RNU (ang. Residual Nonuniformity Correction). The work is an effect of design and building a prototype of the new infrared camera.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 10, 10; 1112-1115
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies