Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Strąkowska, M." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Automatic eye corners detection and tracking algorithm in sequence of thermal medical images
Autorzy:
Strąkowska, M.
Strąkowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/114658.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
eye corners detection
point tracking
IR thermography
thermal image processing
Opis:
The article presents automatic eye corners detection algorithms in thermal images. Its target application is to perform quick and unnoticed measurement of human body temperature. It is proved that the temperature of eyes’ corners is the most reliable and stable temperature considering infrared imaging. That measurements were done manually so far. Our approach is to do this automatically and create complete system for measurement of core human body temperature in crowded places where it is impossible to do this in another way (for example on the airport, railway station). Such system could prevent people for spreading off the epidemic. Two proposed algorithms are presented: first based on morphological operations and geometric features of human face, second based on the cross-correlation and idea of pattern tracking. The selection of appropriate ROI size for reliable temperature extraction was tested according to the distance to person under observation.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 199-202
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metrologiczna kamera termowizyjna z detektorem mikrobolometrycznym VOx
Metrological thermovision camera with VOx microbolometer
Autorzy:
Strąkowski, R.
Strąkowska, M.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/154583.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termowizja
budowa kamery termowizyjnej
korekcja niejednorodności
thermovision
infrared camera construction
nonuniformity correction
Opis:
W artykule opisano budowę kamery termowizyjnej zaprojektowanej i wykonanej w Instytucie Elektroniki Politechniki Łódzkiej. Opisano blokowy schemat układu elektronicznego współczesnej kamery termowizyjnej. Omówiono proces akwizycji i korekcji obrazu termowizyjnego podczas jego transmisji na całej długości toru transmisyjnego kamery, od detektora do komputera. Przedstawiono operacje wykonywane na sygnale analogowym w układzie odczytu detektora oraz metody cyfrowej korekcji termogramu w czasie rzeczywistym zaimplementowane w procesorze sygnałowym.
In this paper construction of a new thermovision camera together with its parameters are presented. The camera was designed and realized in the Institute of Electronics at Technical University of Lodz. At first, the block diagram of a modern infrared camera was analyzed. It was divided into two parts: detectors and control-processing sections. First section, apart from VOx detector, contained also analog power suppliers, a focal plane array temperature stabilization circuit and a digital to analog converter. The second section consisted of a digital signal processor, SRAM and nonvolatile memories, a programmable logic device and the Ethernet interface for image transmission. The overall logic was implemented in a CPLD device for controlling the VOx detector. The image acquisition and correction processes along the whole transmission path are presented. Real time non-uniformity and bad pixel corrections performed by a powerful digital signal processor are described. Finally, the calibration process existing for every metrological camera and conclusions are given.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 10, 10; 1104-1107
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Perfusion and Thermal Parameters of Skin Tissue Using Cold Provocation and Thermographic Measurements
Autorzy:
Strąkowska, M.
Strąkowski, R.
Strzelecki, M.
De Mey, G.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/220811.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active thermovision
perfusion
thermal model
skin tissue
measurement uncertainty
Opis:
Measurement of the perfusion coefficient and thermal parameters of skin tissue using dynamic thermography is presented in this paper. A novel approach based on cold provocation and thermal modelling of skin tissue is presented. The measurement was performed on a person’s forearm using a special cooling device equipped with the Peltier module. The proposed method first cools the skin, and then measures the changes of its temperature matching the measurement results with a heat transfer model to estimate the skin perfusion and other thermal parameters. In order to assess correctness of the proposed approach, the uncertainty analysis was performed.
Źródło:
Metrology and Measurement Systems; 2016, 23, 3; 373-381
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Importance of radiative heat transfer for infrared thermography measurements
Znaczenie radiacyjnej wymiany ciepła w pomiarach termowizyjnych
Autorzy:
De Mey, G.
Więcek, B.
Kałuża, M.
Olbrycht, R.
Strąkowski, R.
Strąkowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/154589.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
radiacyjna wymiana ciepła
termografia
promieniowanie podczerwone
heat transfer by radiation
thermography
infrared radiation
Opis:
The basics of heat transfer by radiation will be shortly outlined: Planck's law, Stefan Boltzmann's law, emissivity, construction of a black body, effective emissivity, reflection. Several applications for infrared thermography, basic physical principles of microbolometer detector, non uniformity correction without shutter and blocking the image and some original experiments will be discussed afterwards. The main conclusion of this work is that calibration of metrological cameras has to be performed for different temperature of their housing.
W artykule przedstawiono podstawy wymiany ciepła przez radiację: prawo Plancka, Stefana Boltzmanna, emisyjność materiałów, budowę ciała doskonale czarnego, efektywną emisyjność oraz prawo odbicia. Omówiono również niektóre aplikacje w termografii w podczerwieni, w których wykorzystuje się efekty radiacyjne. Omówiono fizyczne podstawy działania detektora mikrobolometrycznego, korekcję niejednorodności matrycy bolometrycznej bez migawki i blokowania obrazu oraz wybrane oryginalne eksperymenty. Przedstawiono wpływ promieniowania obudowy na działanie detektora i kamery termowizyjnej oraz zastosowanie pierścieni pośrednich w badaniach termowizyjnych.Niestety obudowa i pierścienie emitują pasożytnicze promieniowanie, które musi być uwzględnione w pomiarach termowizyjnych. Wnioskiem z pracy jest stwierdzenie, że w metrologicznej kamerze termowizyjnej, kalibracja powinna być przeprowadzona dla różnych wartości temperatury obudowy. Mówimy wówczas o korekcji RNU (ang. Residual Nonuniformity Correction). The work is an effect of design and building a prototype of the new infrared camera.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 10, 10; 1112-1115
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies