Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Rating" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Blackout prevention possibility using dynamic thermal line rating
Zastosowanie dynamicznej cieplnej obciążalności linii przesyłowych jako możliwości zapobiegania blackoutom
Autorzy:
Staszewski, Ł.
Rebizant, W.
Powiązania:
https://bibliotekanauki.pl/articles/410569.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
dynamic thermal line rating
blackout prevention
heat equation
Opis:
This paper presents the Dynamic Thermal Line Rating (DTLR) application, based on the heat equations, that makes possible overhead transmission lines operation over their conservatively designed current ratings. The DTLR concept is well known - owing to the CIGRE [1,2] and IEEE [3] standards for overhead bare conductor temperature calculations. However, this phenomenon may not have been used for a purpose of increasing electrical power system stability and thus for blackout prevention. This paper is based on both CIGRE and IEEE standards and presents investigation of the current flow through various conductors. Their temperature and monitoring ambient weather conditions and thermal limits of a conductor are considered. The influence of the weather conditions on the lines flow capacities is presented as a comparison of various types of AFL 6 conductor and various weather conditions. Also the short analysis of the recent blackouts and possibilities of DTLR use are presented. Obtained results are described and conclusions are drawn.
Artykuł przedstawia zastosowanie dynamicznej termicznej obciążalności linii przesyłowych (DTOLP) jako narzędzia umożliwiającego unikanie powstawania lub dalszego rozwoju powstałej już awarii wielkoobszarowej systemu elektroenergetycznego. Sama idea DTOLP jest dobrze znana, dzięki standardom CIGRE i IEEE służącym do obliczeń termicznego stanu przewodu jako funkcji warunków pogodowych oraz przepływającego przez przewód prądu elektrycznego. Na potrzeby artykułu korzystano z obu standardów i zaprezentowano analizę wpływu przepływu prądu w różnych przewodach na ich możliwości przesyłowe w zależności od otaczających je warunków pogodowych. Dodatkowo artykuł podkre sla istotność przeciążeń linii przesyłowych, jako elementu wywołującego lub pogłębiającego awarie wielkoobszarowe oraz możliwość zastosowania dynamicznej termicznej obciążalności linii przesyłowych w celu zapobiegania tym zjawiskom.
Źródło:
Present Problems of Power System Control; 2011, 1; 15-21
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Distance protection with dynamic thermal line rating enhancement
Autorzy:
Staszewski, Ł.
Rebizant, W.
Powiązania:
https://bibliotekanauki.pl/articles/410531.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
dynamic thermal line rating
distance protection
overload
heat balance
Opis:
As the worldwide analysis of recent wide area cascading failures have shown, very often the main cause of blackout was mal-operation of the third zone of a distance protection relay. The load encroachment and power swing phenomena are the two dire problems to solve when dealing with the third zone of distance protection mal-function. The vast number of blackouts could have been avoided or the consequences lowered if the distance relay had not operated due to controlled impedance encroachment.This paper proposes a new approach to enhance the distance protection relay operation by introducing a new blocking algorithm. The algorithm is based on Dynamic Thermal Line Rating (DTLR) idea to restrain relay from tripping when conditions in electrical power system and weather conditions allow for it.
Źródło:
Present Problems of Power System Control; 2012, 2; 73-84
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal calculation for distance protection enhancement
Autorzy:
Staszewski, Ł
Rebizant, W
Powiązania:
https://bibliotekanauki.pl/articles/410608.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
dynamic thermal line rating
distance protection
power swing
third zone
Opis:
Worldwide analysis of recent wide area cascading failures has shown that very often their main cause was the mal-operation of the distance protection relay third zone. The load encroachment and power swing phenomena are the two dire problems to solve when dealing with the third zone of distance protection. The vast number of blackouts could have been avoided or the consequences lowered if the distance relay had not operated due to impedance encroachment while there was no risk of further, continuous operation. This paper proposes a way to improve operation of the distance protection relay by introducing a new blocking algorithm that uses the Dynamic Thermal Line Rating (DTLR) to restrain relay from tripping when conditions in electrical power system allow for it.
Źródło:
Present Problems of Power System Control; 2013, 3; s. 83-94
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies