Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Stachniewicz, R." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Using Thermography to Locate Air Leakages through the envelope of a Building in the summer season
Autorzy:
Stachniewicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/114210.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termography
envelope air-leakness
airtightness test
Opis:
The article presents how to use thermography to locate leakages through the air envelope of three selected single-family houses. Identification of air leakage was possible using differential analysis of thermal images recorded during a pressure test of the buildings as thermovision sequences. This enabled the detection of leakages through envelopes of the buildings at small summer internal and external temperature differences from 2 to 5(C.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 261-264
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody oceny efektywnej grubości docieplania ścian zewnętrznych
Methods of estimation of the effective thickness of insulating outer walls
Autorzy:
Stachniewicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/402745.pdf
Data publikacji:
2012
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
fizyka budowli
termomodernizacja
efektywność inwestycji
thermomodernization
effective
wall
Opis:
Dużą rolę przy określaniu efektywnej grubości izolacji termicznej ma przyjęta metoda oceny. Najczęściej spotykana prosta metoda oceny, na przykład SPBT, wskazuje na inne efektywne grubości niż metody wykorzystujące technikę dyskonta, na przykład NPV. Rozbieżności w efektywnej grubości wynikają przede wszystkim z faktu, iż metoda prosta SPBT zawęża okres rachunku do czasu zwrotu nakładów, natomiast metody dyskontowe obejmują rachunkiem ekonomicznym cały okres funkcjonowania inwestycji. Ponadto w artykule przeanalizowano wpływ cen 5 nośników energii na efektywną grubość izolacji termicznej w przykładowym domu jednorodzinnym. Efektywną grubość izolacji termicznej określono stosując prosty czas zwrotu SPBT i zaktualizowaną wartość netto NPV.
The applied method of the judgement plays a vital role in case of the determination of effective thickness of thermal isolation. Simple methods (such as SPBT - Simple Pay Back Time) point at other effective thicknesses than the methods making use of the discount technique (for example NPV – Net Present Value). The effective thickness of thermal isolation calculated with the simple method (SPBT) will be different from the second one, calculated with the method NPV. It results from the fact that the calculations making use of the SPBT method include solely the period of the expenses refund. On the other hand the calculations making use of the discount technique involve the whole period of the investment duration. Additionally in the report the influence of five kinds of fuel on effective thickness of thermal insulation in the hypothetical cottage has been analysed. The effective thickness of thermal insulation was determined applying the criterion simple payback time SPBT and net present value NPV.
Źródło:
Budownictwo i Inżynieria Środowiska; 2012, 3, 2; 103-108
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of thermography for determining places in danger of the mold growth in residential buildings
Autorzy:
Stachniewicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/95599.pdf
Data publikacji:
2018
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
building physics
thermography
humidity
biological degradation
microclimate
fizyka budowli
termografia
wilgotność
degradacja biologiczna
mikroklimat
Opis:
The mold present in buildings is a factor causing, among others, threat to the health of residents, degradation of building materials, destruction of wall surfaces and furniture adjacent to molded partitions. This article examines the usefulness of thermography to identify areas at risk of mold growth in homes. For this purpose, a thermal imaging camera was used to create thermograms of building partitions. The thermograms were processed to determine the possibility of mold appearance and the extent of its development. The presence of moisture on barrier surface is one of the preconditions for mold growth. Thermogram analyses were carried out using three methods for determining critical temperature below which moisture condensation occurs on the surface of the barrier. A method based on the surface temperature factor proved to be the most useful one to determine the extent of mold development fRsi. The usefulness of the thermovision method to determine the area of mold growth has been verified practically through visible traces of mycelium on the examined walls and ceilings. When analyzing thermograms, it is required to take many factors into account. Therefore, a person interpreting thermograms must have appropriate knowledge in the field of thermovision and building physics.
Źródło:
Ekonomia i Środowisko; 2018, 3; 142-156
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zapotrzebowanie na ciepło do ogrzewania budynku a zawilgocenie ścian zewnętrznych
Heat demand for building heating and outside walls dampness
Autorzy:
Stachniewicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/402801.pdf
Data publikacji:
2012
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
diagnostyka cieplna
zawilgocenie przegród
fizyka budowli
walls dampness
energy
building
Opis:
W artykule przeprowadzono analizę wpływu zawilgocenia ścian zewnętrznych jednorodzinnego budynku mieszkalnego na energię końcową. Do analiz przyjęto dwa warianty zawilgocenia ścian: bezpośrednio po wybudowaniu i po pięciu latach eksploatacji budynku.
This paper analyses the influence of external walls dampness for single-family house on the final energy. For the analysis two variants of damp walls were assumed: immediately after construction and after five years of exploitation of the building.
Źródło:
Budownictwo i Inżynieria Środowiska; 2012, 3, 3; 147-152
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda wyznaczania efektywnej grubości izolacji termicznej w budynkach mieszkalnych i użyteczności publicznej przy uwzględnieniu źródła ciepła
Method of determination of thermal insulation effective thickness in residential and public buildings when considering the heat source
Autorzy:
Stachniewicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/402926.pdf
Data publikacji:
2015
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
termomodernizacja budynków
system ciepłowniczy
efektywność inwestycji
ekologia
thermo-modernization of buildings
heating system
investment efficiency
ecology
Opis:
W artykule przedstawiono analizę efektywnych grubości docieplenia w miejskich systemów grzewczobudowlanych wykonaną na bazie Masterplanów w dziewiętnastu miastach. Wprowadzono podział systemów na trzy rodzaje: z deficytem mocy, zrównoważone i z nadwyżką mocy w źródle ciepła. Dla każdego z nich przedstawiono algorytm obliczeń efektywnej grubości docieplenia z uwzględnieniem dopasowania mocy źródła. Sformułowane algorytmy uwzględniają efekty unikniętych inwestycji w rozbudowę źródła ciepła oraz efekty ekologiczne. Wykorzystując opracowane algorytmy przeprowadzono obliczenia efektywności wybranych przedsięwzięć termomodernizacyjnych i analizę porównawczą z wynikami obliczeń optymalizacyjnych wykonanymi według obecnych aktów wykonawczych do ustawy o wspieraniu przedsięwzięć termomodernizacyjnych.
The paper presents an analysis of urban heat – building systems. The analysis was made on the basis of Masterplans in 19 towns. The division of systems into 3 types: a shortage of power, balanced power and surplus power in the source of heat was shown. The algorithm of efficiency of thermal modernization undertakings was given for systems mentioned above. The algorithm takes into consideration a lack of modernization investments in the thermal source and ecological effect. Efficiency of thermal modernization investments was calculated, which was the basis of comparative analysis for the results of calculation according to the law in force. The algorithm can be used to calculate the efficiency of thermal modernization undertakings if there is only one owner of buildings and thermal source.
Źródło:
Budownictwo i Inżynieria Środowiska; 2015, 6, 1; 37-40
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies