Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Sobczak, B." wg kryterium: Autor


Wyświetlanie 1-7 z 7
Tytuł:
The use of generic models in dynamic analyses of the synchronous system of continental Europe
Wykorzystanie modeli generycznych w analizach dynamicznych synchronicznego systemu kontynentalnej Europy
Autorzy:
Sobczak, B.
Trębski, R.
Wilk, M.
Powiązania:
https://bibliotekanauki.pl/articles/397153.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
generic models
inter-area oscillations
inter-area modes
small signal stability
load modelling
model generyczny
oscylacje międzyobszarowe
mody międzyobszarowe
stabilność małosygnałowa
modelowanie odbioru
Opis:
Development of a dynamic model covering a large power system and suitable for analyses of inter-area oscillations often requires the use of typical system component models used in transient stability analyses. This may consequence in very optimistic results, i.e. much better oscillation damping than actually recorded in the system. This was seen in the 1990s, when in the USA and Canada (Western Interconnection) weakly damped inter-area oscillations were observed, which could not be correctly reflected using standard dynamic models. The paper analyses selected system component modelling simplifications due to the use of generic models that may affect the damping of inter-area oscillations. The degree of this impact on the results is shown in a dynamic model covering the synchronously operated part of the continental Europe system.
Opracowanie modelu dynamicznego, obejmującego wielki system elektroenergetyczny odpowiedni do analiz oscylacji międzyobszarowych, często wymaga wykorzystania typowych modeli elementów systemu, wykorzystywanych w analizach stanów przejściowych. Działanie takie może skutkować uzyskaniem bardzo optymistycznych wyników, tj. dużo lepszego tłumienia oscylacji niż w praktyce rejestrowane w systemie. Przekonano się o tym już w latach 90., gdy zaobserwowano słabo tłumione oscylacje międzyobszarowe w USA i Kanadzie (Western Interconnection), których nie udało się poprawnie odwzorować z wykorzystaniem standardowych modeli dynamicznych. W artykule przeanalizowano wybrane uproszczenia modelowania elementów systemu, spowodowane wykorzystaniem modeli generycznych, które mogą mieć wpływ na poziom tłumienia oscylacji międzyobszarowych. Stopień tego oddziaływania na wyniki został pokazany na modelu dynamicznym, obejmującym synchronicznie pracującą część Europy kontynentalnej.
Źródło:
Acta Energetica; 2017, 4; 14-20
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Load Compensation in Voltage Controllers of Large Generators in the Polish Power Grid
Wykorzystanie kompensacji prądowej w regulatorach napięcia generatorów systemowych Krajowego Systemu Elektroenergetycznego
Autorzy:
Sobczak, B.
Rink, R.
Głaz, M.
Powiązania:
https://bibliotekanauki.pl/articles/397324.pdf
Data publikacji:
2014
Wydawca:
ENERGA
Tematy:
load compensation
Automatic Voltage Regulator (AVR)
AVR
kompensacja prądowa
regulator napięcia generatora
generator
Opis:
The Automatic Voltage Regulator normally controls the generator stator terminal voltage. Load compensation is used to control the voltage which is representative of the voltage at a point either within or external to the generator. In the Polish Power Grid (PPG) compensation is ready to use in every AVR of a large generator, but it is utilized only in the case of generators operating at the same medium voltage buses. It is similar as in most European Power Grids. The compensator regulating the voltage at a point beyond the machine terminals has significant advantages in comparison to the slower secondary Voltage and Reactive Power Control System (ARNE)1. The compensation stiffens the EHV grid, which leads to improved voltage quality in the distribution grid. This effect may be particularly important in the context of the dynamic development of wind and solar energy.
Kompensacja regulacji napięcia prądem generatora przesuwa punkt regulacji napięcia z zacisków generatora w kierunku sieci lub do wewnątrz generatora. W krajowym systemie elektroenergetycznym (KSE) kompensacja jest możliwa we wszystkich regulatorach napięcia dużych generatorów, jednak stosowana jest tylko wówczas, gdy pracują one na wspólne szyny średniego napięcia. Podobnie jest w zdecydowanej większości systemów europejskich. Tymczasem wydaje się, że przesunięcie punktu szybkiej regulacji napięcia w stronę sieci ma dość istotne zalety, których nie ma wolniejsza wtórna regulacja napięcia, realizowana w KSE przez układy automatycznej regulacji napięcia elektrowni (ARNE) . Korzyścią stosowania kompensacji jest m.in. usztywnienie napięć w sieci przesyłowej, a więc poprawa jakości napięcia także w sieciach niższych napięć. W warunkach dynamicznego rozwoju energetyki odnawialnej wykorzystującej wiatr i słońce, zwiększającej zmienność m.in. napięcia sieci, ten efekt zastosowania kompensacji może okazać się szczególnie ważny. W ubiegłym roku operator PSE SA rozpoczął realizację obszernej dwuetapowej pracy poświęconej zastosowaniu kompensacji regulacji napięcia w generatorach elektrowniach Bełchatów, Kozienice, Ostrołęka i Żarnowiec. Artykuł prezentuje wybrane zagadnienia, uzyskane w pierwszym etapie prac, który był poświęcony w większości badaniom modelowym.
Źródło:
Acta Energetica; 2014, 1; 152-165
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wpływu wyłączania i załączania mocno obciążonej linii przesyłowej na pracę elektrowni z turbogeneratorami
Autorzy:
Kąkol, A.
Sobczak, B.
Trębski, R.
Powiązania:
https://bibliotekanauki.pl/articles/397350.pdf
Data publikacji:
2011
Wydawca:
ENERGA
Tematy:
turbogenerator
linia przesyłowa
obciążenie
transmission line
load
Opis:
Rozwój europejskiego rynku energii oraz rozwój energetyki odnawialnej przyczyniają się do występowania w systemie dużych przesyłów mocy, w tym także niepożądanych przepływów kołowych. Jeżeli takie przesyły mają miejsce w pobliżu elektrowni i dotyczą pojedynczego ciągu (np. linii wymiany), to mogą one powodować zagrożenia związane z potencjalnym wymuszonym wyłączeniem linii, a także z ponownym jej załączeniem. Wyłączenie mocno obciążonej linii oznacza silne zaburzenie bilansu mocy czynnej i biernej w sąsiedztwie elektrowni. Ponowne załączenie linii przy znacznym rozchyle kątów napięć powoduje występowanie dużych momentów na wale turbogeneratora. W artykule zostaną przedstawione wyniki symulacji zjawisk elektromagnetycznych i elektromechanicznych, które mają miejsce w sytuacji wyłączenia i załączenia mocno obciążonej linii przesyłowej, przyłączonej do węzła dużej elektrowni z turbogeneratorami.
Źródło:
Acta Energetica; 2011, 3; 23-28
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wprowadzenia specjalnych układów pracy w KSE oraz innych obszarach na obraz kołysań międzyobszarowych w systemie synchronicznym kontynentalnej Europy
Influence of special EHV grid configuration on inter area oscillations in power system of continental Europe
Autorzy:
Trębski, R.
Sobczak, B.
Jankowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/266430.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
bezpieczeństwo systemu
przepływy kołowe
kołysania międzyobszarowe
stabilność małosygnałowa
power system security
loop flows
inter-area oscillations
small signal stability
Opis:
Jednym ze zjawisk występujących w europejskim systemie elektroenergetycznym (ENTSO-E CE) są nieplanowane przepływy mocy. Powodują one realne zagrożenie dla bezpieczeństwa pracy systemu oraz ograniczają zdolności wymiany handlowej. Jednym z narzędzi służących ograniczeniu tego zjawiska są coraz powszechniej stosowane w ENTSO-E przesuwniki fazowe. W szczególnie trudnych warunkach dla obrony systemu przed nadmiernymi przepływami mocy, dla zachowania integralności własnego systemu, operatorzy sieci przesyłowej mogą podjąć decyzje o wprowadzeniu zmian topologicznych skutkujących osłabieniem połączeń międzysystemowych. Szczególnym przypadkiem działań operatorskich może być podział nie na pojedynczej granicy, ale na całym ciągu granic, prowadzący w efekcie do podziału kontynentalnej części ENTSO-E na dwie części wschodnią i zachodnią. Działania takie prowadzą do ograniczenia niepożądanych przepływów, ale mogą również oddziaływać na częstotliwość i tłumienie kołysań międzyobszarowych obserwowanych w systemie. Przedstawione w artykule wyniki stanowią ocenę jakościową (pokazują trendy zmian) wpływu wyłączeń linii granicznych w KSE na wielkość tłumienia i częstotliwości kołysań międzyobszarowych ENTSO-E CE angażujących generatory KSE.
Loop flows observed on continental European power system (ENTSO-E CE) impose limitations on possible market power exchange but above all cause real threat to safe power system operation. To limit this phenomena, transmission system operators (TSOs) install phase shifting transformers on tie-lines. In case this countermeasure is not available or control range of installed devices is not sufficient to limit undesired power flow to safe level, TSOs may decide to change system topology (switch off tie-lines, splitting internal system) aiming to protect internal system integrity but weakening international connections. On one hand this action leads to reduction or elimination of unscheduled power flows but also influences on frequencies and damping of inter-area oscillations. Presented in the paper results discuss qualitative changes in inter-area oscillations pattern (frequency, damping, Polish generators contribution) caused by topology changes introduced to Polish EHV grid. Due to problems with low frequency inter-area oscillations damping either deterioration of damping or lowering the frequency may be treated as potential threat to European system safety. Additional scenario analyzing deeper changes in ENTSO-E CE system: split into western and eastern part was also investigated.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 53; 35-38
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of the polish tie-lines’ outages on the inter-area oscillations pattern in the synchronous system of continental Europe
Wpływ wyłączeń linii granicznych KSE na obraz oscylacji międzyobszarowych w systemie synchronicznym kontynentalnej Europy
Autorzy:
Jankowski, R.
Sobczak, B.
Trębski, R.
Powiązania:
https://bibliotekanauki.pl/articles/397441.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
system security
loop flows
inter-area oscillations
small signal stability
bezpieczeństwo systemu
przepływy kołowe
oscylacje międzyobszarowe
stabilność małosygnałowa
Opis:
Loop flows in the European power system (ENTSO-E CE) not only limit trade capacity, but also compromise power system operational security. In order to reduce unscheduled power transfers, phase shifters are most commonly used, usually installed on tie-lines. Where these devices are not available or their control range has been exhausted, and the unscheduled power transfer is greater than the allowable, transmission grid operators, in extreme cases, to maintain the integrity of their own systems may decide to introduce topological changes resulting in interconnection weakening. Such action reduces the undesired power transfer, but at the same time it affects the frequency and the damping of inter-area oscillations in the ENTSO-E CE system. The results presented in this paper provide a qualitative assessment (show trends of changes) of the impact of the Polish NPS (National Power System) border lines’ outages on the damping and frequency, and the contribution of NPS generators to inter-area oscillations. Due to the problems with low frequency oscillation damping in ENTSO-E CE, any reduction in the damping or frequency from the initial state should be considered a potential threat to secure system operation.
Obserwowane w pracy europejskiego systemu elektroenergetycznego (ENTSO-E CE) przepływy kołowe powodują nie tylko ograniczenie zdolności wymiany handlowej, ale również stwarzają realne zagrożenie dla bezpieczeństwa pracy systemu. W celu ograniczenia takich przesyłów coraz powszechniej stosowane są przesuwniki fazowe instalowane zazwyczaj na liniach granicznych. W sytuacji, gdy urządzeń tych nie ma, czy też ich zakres regulacyjny został wyczerpany, a niepożądany przesył jest większy od dopuszczalnego, operatorzy sieci przesyłowej w skrajnych przypadkach, dla zachowania integralności własnego systemu, mogą podjąć decyzje o wprowadzeniu zmian topologicznych, skutkujących osłabieniem połączeń międzysystemowych. Działanie takie prowadzi do ograniczenia niepożądanego przesyłu, ale równocześnie oddziałuje na częstotliwość i tłumienie oscylacji międzyobszarowych obserwowanych w ENTSO-E CE. Przedstawione w artykule wyniki dokonują oceny jakościowej (pokazują trendy zmian) wpływu wyłączeń linii granicznych w KSE na wielkość tłumienia i częstotliwości oraz zaangażowania generatorów KSE w oscylacjach międzyobszarowych. Ponieważ w ENTSO-E CE występują problemy z tłumieniem oscylacji niskich częstotliwości, to każde zmniejszenie tłumienia lub częstotliwości w stosunku do stanu wyjściowego należy traktować jako potencjalne zagrożenie dla bezpieczeństwa pracy.
Źródło:
Acta Energetica; 2017, 2; 89-97
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fast-Valving of Large Steam Turbine Units as a Means of Power System Security Enhancement
Szybkie zaworowanie turbin parowych dużych bloków jako środek zwiększenia bezpieczeństwa krajowego systemu elektroenergetycznego
Autorzy:
Sobczak, B.
Rink, R.
Kuczyński, R.
Trębski, R.
Powiązania:
https://bibliotekanauki.pl/articles/397462.pdf
Data publikacji:
2014
Wydawca:
ENERGA
Tematy:
fast-valving
power system stability
electric power engineering
szybkie zaworowanie
elektroenergetyka
Opis:
Fast-valving assists in maintaining system stability following a severe transmission system fault by reducing the turbine mechanical power. Fast-valving consists in rapid closing and opening of steam valves in an adequate manner to reduce the generator accelerating power following the recognition of a severe fault. FV can be an effective and economical method of meeting the performance requirements of a power system in the presence of an increase in wind and solar generation in the power system, newly connected large thermal units and delaying of building new transmission lines. The principle of fast-valving and advantages of applying this technique in large steam turbine units was presented in the paper. Effectiveness of fast-valving in enhancing the stability of the Polish Power Grid was analyzed. The feasibility study of fast-valving application in the 560 MW unit in Kozienice Power Station (EW SA) was discussed.
Autorzy przedstawili w artykule zasady działania szybkiego zaworowania (ang. fast-valving) i korzyści stosowania tej techniki we współczesnych systemach elektroenergetycznych. Omówione zostały modelowe badania skuteczności FV w warunkach KSE oraz analiza możliwości wprowadzenia FV na bloku 560 MW elektrowni Kozienice, wykonane w ramach I etapu pracy IASE Wrocław i Instytutu Energetyki Oddział Gdańsk dla Polskich Sieci Elektroenergetycznych SA, której przedmiotem jest analiza możliwości zastosowania FV w pracujących w KSE i planowanych do przyłączenia dużych blokach konwencjonalnych.
Źródło:
Acta Energetica; 2014, 1; 166-175
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szybkie zaworowanie turbin parowych dużych bloków jako środek zwiększenia stabilności krajowego systemu Elektroenergetycznego
Fast-valving of large steam turbine units as means of power system security enhancement logic
Autorzy:
Sobczak, B.
Rink, R.
Kuczyński, R.
Trębski, R.
Powiązania:
https://bibliotekanauki.pl/articles/267671.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
szybkie zaworowanie
fast-valving
fast valving
power system stability
Opis:
W referacie przedstawiono zasady działania szybkiego zaworowania (fast-valving) i korzyści stosowania tej techniki we współczesnych systemach elektroenergetycznych. Omówione zostały modelowe badania skuteczności FV w warunkach KSE oraz analiza możliwości wprowadzenia FV na bloku 560 MW El. Kozienice, wykonane w ramach I etapu pracy IASE Wrocław i Instytutu energetyki Oddział Gdańsk dla PSE SA, której przedmiotem jest analiza możliwości zastosowania FV w pracujących w KSE i planowanych do przyłączenia dużych blokach konwencjonalnych.
Fast-valving assists in maintaining system stability following a severe transmission system fault by reducing the turbine mechanical power. Fast-valving consists in rapid closing and opening of steam valves in adequate manner to reduce the generator accelerating power following the recognition of a severe fault. FV can be an effective and economical method of meeting the performance requirements of power system in the presence of the increase of wind and solar generation in power system and newly connected large thermal units and delaying of building new transmission lines. The principle of fast-valving and advantages of application this technique in large steam turbine units were presented in the paper. Effectiveness of fast-valving in enhancing the stability of Polish Power Grid was analyzed. Feasibility study of fast-valving application in the 560 MW unit in Kozienice Power Station (EW SA) was discussed.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 32; 115-118
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies