Tytuł:
Current ripple reduction for finite control set model predictive control strategy of grid-tied inverter with reference current compensation
Autorzy:
Jin, Nan
Fan, Wuchuang
Fang, Jie
Wu, Jie
Shen, Yongpeng
Powiązania:
https://bibliotekanauki.pl/articles/2202542.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cost function
current ripple reduction
finite control set model predictive control
FCS-MPC
grid-tied inverter
reference current compensation
RCC
Opis:
In the finite control set model predictive control (FCS-MPC) strategy of the grid-tied inverter, the current ripple (CR) affects the selection of optimal voltage vectors, which leads to the increase of output current ripples. In order to solve this problem, this paper proposes a CR reduction method based on reference current compensation (RCC) for the FCS-MPC strategy of grid-tied inverters. Firstly, the influence of the CR on optimal voltage vector selection is analyzed. The conventional CR prediction method is improved, which uses inverter output voltage and grid voltage to calculate current ripples based on the space state equation. It makes up for the shortcomings that the conventional CR prediction method cannot predict in some switching states. The improved CR method is more suitable for the FCS-MPC strategy. In addition, the differences between the two cost functions are compared through visual analysis. It is found that the sensitivity of the square cost function to small errors is better than that of the absolute value function. Finally, the predicted CR is used to compensate the reference current. The compensated reference current is substituted into the square cost function to reduce the CR. The experimental results show that the proposed method reduces the CR by 47.3%. The total harmonic distortion (THD) of output current is reduced from 3.86% to 2.96%.
Źródło:
Archives of Electrical Engineering; 2023, 72, 1; 5--22
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies