Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kociński, J." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Binaural masking of amplitude modulation
Autorzy:
Kordus, M.
Sęk, A.
Kociński, J.
Powiązania:
https://bibliotekanauki.pl/articles/177557.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
masking
masking in the modulation domain
modulation filterbank
Opis:
A new concept concerned with the transformation of acoustic stimuli in the auditory system postulates the existence of a form of spectral analysis applied to the amplitude changes of the stimuli. It is assumed that this analysis takes place in the so-called modulation filters, i.e. bandpass linear filters tuned to different rates of the amplitude changes. The most striking argument supporting this idea is an effect of masking in the amplitude modulation domain whose nature can be easily explained basing on this concept. As the modulation filters are situated on the higher levels of the auditory system, it is also assumed that this form of masking is entirely a central process. However, most of the studies concerned with masking in the modulation domain used monaural listening only. Therefore, the main purpose of the presented here experiments was to investigate whether this type of masking is entirely a central process. Using a Three-Alternative Forced-Choice (3AFC) procedure the binaural and monaural masked thresholds of amplitude modulation were determined. A sinusoidal carrier at a frequency of 4 kHz was amplitude modulated by a specially designed band of noise characterized by a very low value of the crest factor, which was used as a masking signals. Different bandwidths of the modulating masking signals were used as well as different center frequencies to investigate whether the masking patterns in the modulation domain depend on the masker bandwidth and its center frequency. The modulating target (masked) signal was a pure tone at a frequency range from 2 to 256 Hz. Both modulating signals were applied to the same sinusoidal carrier signal. The most effective masking was noticed when the rate of the sinusoidal modulation was close to the center frequency of the masking signal or when it was in its spectral range and decreased outside of this range. The character of this dependence confirms the existence of some form of a frequency selectivity in the modulation rate domain similarly to the audible frequency domain. The thresholds for monaural and binaural listening were very close to each other. This implies that masking in the modulation domain is a central process.
Źródło:
Archives of Acoustics; 2005, 30, 1; 5-17
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Convolutive Blind Signal Separation Spatial Effectiveness in Speech Intelligibility Improvement
Autorzy:
Kociński, J.
Sęk, A.
Libiszewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/1504381.pdf
Data publikacji:
2011-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.72.-p
43.60.-c
43.60.+d
Opis:
Blind signal separation is one of the latest methods to improve the signal to noise ratio. The main objective of blind source separation is the transformation of mixtures of recorded signals to obtain each source signal at the output of the procedure, assuming that they are statistically independent. For acoustic signals it can be concluded that the correct separation is possible only if the source signals are spatially separated. That finding suggests analogies with the classical spatial filtering (beamforming). In this study we analyzed an effect of the angular separation of two source signals (i.e. speech and babble noise) to improve speech intelligibility. For this purpose, we chose the blind source separation algorithm based on the convolutive separation, based on second order statistics only. As a system of sensors a dummy head was used (one microphone inside each ear canal), which simulated two hearing aids of a hearing impaired person. The speech reception threshold, before and after the blind source separation was determined. The results have shown significant improvement in speech intelligibility after applying blind source separation (speach reception threshold fell even more than a dozen dB) in cases where the source signals were angularly separated. However, in cases where the source signals were coming from the same directions, the improvement was not observed. Moreover, the effectiveness of the blind source separation, to a large extent, depended on the relative positions of signal sources in space.
Źródło:
Acta Physica Polonica A; 2011, 119, 6A; 996-999
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies