Tytuł:
Results of Experiments with Fiber Pressure Sensor Applied in the Polish Artificial Heart Prosthesis
Autorzy:
Konieczny, G.
Opilski, Z.
Pustelny, T.
Gacek, A.
Gibinski, P.
Kustosz, R.
Powiązania:
https://bibliotekanauki.pl/articles/1506799.pdf
Data publikacji:
2010-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.79.-e
42.81.-i
07.07.Df
47.63.Cb
Opis:
The following paper introduces the problem of noninvasive pressure measurements in Polish artificial heart prosthesis. The pressure sensor is proposed and introduced, and preliminary tests are shown. The paper deals with the proposed sensing elements, requirement noninvasive solution and preliminary tests of polyurethane membrane transmission. The paper includes also experimental results of a fiber pressure sensor introducing noninvasive pressure measurements with pressure transmission through a polyurethane tube wall.
Źródło:
Acta Physica Polonica A; 2010, 118, 6; 1183-1185
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Noninvasive acoustic blood volume measurement system for the POLVAD prosthesis
Autorzy:
Opilski, Z.
Konieczny, G.
Pustelny, T.
Gacek, A.
Kustosz, R.
Gawlikowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/200093.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heart prosthesis
medical acoustics
blood volume measurement system
Opis:
The following paper presents researches concerning a noninvasive real-time blood volume measurement system applied in POLVAD prosthesis. The system is based on the acoustic Helmholtz resonator principle. The basis of the measurement method, followed by the preliminary tests of the possibility of incorporating the Helmholtz resonance idea into the POLVAD prosthesis is shown. The paper includes the actual measurement system construction and test results, both static and dynamic obtained at the Foundation for Cardiac Surgery Development in Zabrze, Poland. Conclusions and future plans are presented too.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 429-433
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies