Tytuł:
Evaluation of diagnostic information about marine engine work based on mesurement of the angular speed discrete value
Autorzy:
Dereszewski, M.
Charchalis, A.
Polanowski, S.
Powiązania:
https://bibliotekanauki.pl/articles/247911.pdf
Data publikacji:
2012
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
diagnostics
marine diesel engine
angular speed
photo optical signal
failure simulation
Opis:
The paper presents results of the experiment, aimed on finding the answer whether IAS (Instantaneous Angular Speed) and angular acceleration of the crankshaft is carrying information about quality of combustion in cylinder of the diesel engine. The experiment was carried out at laboratory stand in Gdynia Maritime University, equipped with diesel engine Sulzer 3AL 25/30 driving electro-generator. Sulzer 3AL 25/30 is three cylinder, medium speed, four stroke marine diesel engine, with maximum output 408 kW at 750 rpm. In order to evaluate of IAS utility for diagnosis of the engine, two kinds of malfunctions of engine's fuel system were simulated. First malfunction was fuel leakage from high-pressure line; the second was partly plugged injector's nozzle. Construction of high-pressure fuel pump enables to simulate fuel leakage. The level of leakage was controlled by simultaneous measurement of pressure in the high-pressure tube. For simulation of injector malfunction, the chocked one was installed in second cylinder. The engine was running at different loads, starting from around 25% up to 70% of nominal. The IAS was measured and recorded by the measurement system ETNP-10, which mode of operation was based on perforated disc mounted at the shaft and photo-optic sensor counting laser impulses. Results of all measurement were smoothed in order to eliminate a noise. Measurement results of fault condition were compared with healthy engine measurements and with results of in-cylinder pressure diagrams, in order to detect all deviation from normal condition.
Źródło:
Journal of KONES; 2012, 19, 2; 121-128
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies