Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Trawiński, G." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Preliminary analysis of vibration signal test results registered at bench test stand of amv rosomak driving axis
Autorzy:
Walentynowicz, J.
Trawiński, G.
Dyga, G.
Polak, F.
Boruta, G.
Powiązania:
https://bibliotekanauki.pl/articles/242851.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
differential axle gears
test bench
vibration of elements
vibration analysis
Opis:
The methodology of measuring the vibration signal recorded on the casing of wheeled armoured vehicle ROSOMAK driving axis is presented. The study was performed on a test bench for different transmission conditions. A preliminary analysis of the frequency spectra vibration signals recorded. The test stand allows investigation of the differential axle gears under load similar to load during duty operation. It was possible by using the combustion engine and gearboxes and load transmission by using the dynamometer break. Have been described. Three methods of attaching acceleration sensors to differential gears: using screws, magnetic washers and probe handle. The results of comparisons of measurement results obtained using these methods. Finally, the sensors was mount by using the screw connections. Selected positions and points of temperature and vibration measures were described. Values of characteristic frequencies of differential axle gears vibration by moving the drive torque through these boxes were calculated. The spectra of the vibration signal determined during testing gearboxes were shown. It was state that of amplitude-frequency vibration spectra of signals recorded at selected points of differential axle gears casing are clearly visible characteristic frequencies but the vibration the bridge gear unit bridges distorted by vibration of the internal combustion engine and gearboxes. In a further stage of research should be included much larger number of the driving axis differentials investigated in various states of well-known technical conditions and should be lead accord to requirements of the active diagnostic experiment.
Źródło:
Journal of KONES; 2013, 20, 3; 419-426
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods of verification of main transmission gear boxes on test bench using vibration measurement
Autorzy:
Walentynowicz, J.
Trawiński, G.
Wieczorek, M.
Polak, F.
Boruta, G.
Powiązania:
https://bibliotekanauki.pl/articles/247281.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
multi wheeled vehicle
transmission gearbox
vibration measures
test stand
Opis:
The methodology of research and the inspection of the main transmission gearboxes of multi axles armoured vehicle ROSOMAK under operating conditions are described in this article. Tests are carried out on the bench to allow force transmission changes to the extent similar to the loads that occur during vehicle operation. Transmission gear boxes are driven by an internal combustion engine 359 through a reducer (standard engine gearbox). This reducer increase torque and decrease shaft speed similar to condition in the vehicle. On the other side of the transmission, multiplying gearbox coupled with a brake dynamometer were placed. It increases speed according to requirements of the work field of the dynamometer W-230. The combustion engine made possible to measure vibration of transmission gearboxes under the high torque. The torque is greater than obtainable by using electric motors. The value of the inertia moment loading axle shaft was determined using a simplified kinematic diagram. During the tests, vibration were measured at selected points of the housing using different methods of attachment of vibration transducers. First, the screw for assembling the vibration sensor was glued to the hull of gearbox. Second, the sensor was connected with gearbox by permanent magnets. Third, the sensor was used as a hand probe. The results of vibration measured by these methods were compared. Temperature of the gearbox was also measured by using thermocouples and thermovision methods. Selected results are presented and analysed of vibration transmission and its temperature at selected working conditions.
Źródło:
Journal of KONES; 2013, 20, 4; 471-478
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania wstępne diagnozowania nieobciążonych przekładni głównych mostów napędowych KTO Rosomak na podstawie analizy drgań
Preliminary diagnostics investigation of axles final drive for AMV Rosomak based on vibration signal
Autorzy:
Boruta, G.
Dyga, G.
Polak, F.
Trawiński, G.
Walentynowicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/222479.pdf
Data publikacji:
2013
Wydawca:
Akademia Marynarki Wojennej. Wydział Dowodzenia i Operacji Morskich
Tematy:
mosty napędowe
diagnostyka
sygnał wibracyjny
axles driving
diagnostics
vibroacustic signal
Opis:
W artykule opisano przydatność hamownianego stanowiska badawczego do badania zjawisk wibroakustycznych towarzyszących pracy mostów napędowych KTO Rosomak. Podano sposób wykorzystania dostępnej aparatury pomiarowo-analitycznej. Przedstawiono widma amplitudowo-częstotliwościowe sygnałów drganiowych zarejestrowanych przez akcelerometr mocowany w różny sposób w kilku punktach pomiarowych na kadłubach badanych mostów napędowych. Sformułowano wnioski i zalecenia dotyczące dalszych badań.
It has been assessed engine test bench usefulness for vibroacoustic process’s studies which accompany to AMV Rosomak driving axle’s operating. The way of available measurement and analysis equipment utilization has been given. There are presented the amplitude-frequency spectrum of vibration signals registered by accelerometer which is mounted in various ways in a few measuring points on driving axle’s body. The conclusions and recommendations regarding of further studies has been formed.
Źródło:
Zeszyty Naukowe Akademii Marynarki Wojennej; 2013, R. 54 nr 2 (193), 2 (193); 7-19
0860-889X
Pojawia się w:
Zeszyty Naukowe Akademii Marynarki Wojennej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies