Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Jodda, A." wg kryterium: Autor


Wyświetlanie 1-1 z 1
Tytuł:
Evaluation of set-up verification with the analysis of systematic and random errors in radiotherapy - a study of the Great Poland Cancer Centre
Autorzy:
Szczurek, Ł.
Skrobała, A.
Piotrowski, T.
Jodda, A.
Powiązania:
https://bibliotekanauki.pl/articles/147744.pdf
Data publikacji:
2008
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electronic portal devices
positioning patient
three-dimensional-conformal radiation therapy (3D-CRT)
intensity-modulated radiation therapy (IMRT)
oncology
Opis:
The aim of this study was the examination of influence of location tumors and methods of immobilizing on values of geometrical errors during treatment, and the analysis of set-up errors in reference to the method of irradiation in three groups of patients before and after corrections. This study included three groups of patients with prostate cancer (59 patients, 277 portal images), head and neck (60 patients, 285 portal images) and brain tumor (45 patients, 175 portal images). Ratios of IMRT vs. 3D-CRT were respectively: in I group 76% vs. 24%, in II group 95% vs. 5% and III group 83% vs. 17%. Set-up errors were compared in reference to the technique of irradiation and stage of treatment. The displacements were significantly higher in the first group compared with head, neck and brain tumors; 5.66, 4.05, 3.93 mm, respectively. The values of the vector lengths were significantly dependent on the type of irradiation technique (3D-CRT vs. IMRT) only in the first group (p < 0.001). The average of vector length in I, II and III group were significantly reduced from; 5.67, 4.02, 3.91 mm to 5.13, 3.63, 3.57 mm after correction, respectively. The Spearman test is indicating a low negative correlation between set-up errors and the following fractions. The applied methods of patients positioning with prostate cancer produce a worse repeatability than the ones used for patients with head, neck and brain cancers. Portal verification reduces values of set-up errors. Significant differences in the magnitude of displacements before and after correction were observed. No significant differences between value of displacement and number of fraction were revealed.
Źródło:
Nukleonika; 2008, 53, 4; 167-171
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies