Tytuł:
Improved adhesion and growth of osteoblast-like MG-63 cells in cultures on titanium modified by gold particles
Autorzy:
Parizek, M.
Base, T.
Hruby, M.
Lisa, V.
Bacakova, L.
Powiązania:
https://bibliotekanauki.pl/articles/285778.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
metallic materials
titanium
surgical implants
gold microparticles
cell adhesion
cell growth
Opis:
Metallic materials are important for load-bearing bone implants. The osteointegration of these implants can be improved by appropriate surface modifications. Therefore, we present here a study of the cell growth on titanium surfaces modified with films created from gold microparticles. These particles in the form of microplates or polyhedral microcrystals were deposited on titanium plates from ethanol solutions, dried and annealed with a hydrogen flame. Some samples were additionally modified by polyethylene imine. The materials engendered from these modifications were used to investigate the adhesion and growth of human osteoblast-like MG-63 cells on these surfaces in the DMEM medium with 10% of fetal bovine serum. One day after seeding, the highest number of initially adhered cells was found on the surfaces modified by both types of gold microparticles. This trend was the same three and seven days after seeding. The numbers of cells on pure Ti and Ti modified only with gold particles were significantly higher than on samples which were modified with polyethylene imine. The cell spreading areas projected on the materials were significantly larger in cells on the samples with polyethylene imine modification. However, the shape of these cells was mostly rounded or star-like with thin and long protrusions, while on the materials without polyethylene imine, it was mostly polygonal. The cell proliferation activity was estimated from XTT test, based on the activity of mitochondrial enzymes. This test showed that the proliferation activities of osteoblast-like MG-63 cells of the 3rd and 7th days of the experiment were more pronounced on the samples modified only by gold microparticles. Immunofluorescence showed that the focal adhesion plaques containing vinculin and the fibers containing β-actin were most apparent, more numerous and more brightly stained in cells on Ti modified by gold microplates and gold polyhedral microcrystals, especially in comparison with the corresponding samples modified with polyethylene imine (Fig. 1). Thus, it can be concluded that the modification of titanium samples by both types of gold microparticles enhanced the adhesion and growth of MG 63 cells.
Źródło:
Engineering of Biomaterials; 2013, 16, no. 122-123 spec. iss.; 77
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Black Orlon as promising material for bone tissue engineering
Autorzy:
Parizek, M.
Vetrik, M.
Hruby, M.
Lisa, V.
Bacakova, L.
Powiązania:
https://bibliotekanauki.pl/articles/284127.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Orlon
polyacrylonitrile
tissue engineering
porous 3D scaffolds
cell adhesion
cell growth
osteoblasts
Źródło:
Engineering of Biomaterials; 2014, 17, no. 128-129; 4-6
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The adhesion and growth of vascular smooth muscle cells in cultures on carboranethiol-modified gold films
Autorzy:
Parizek, M.
Base, T.
Londesborough, M. G. S.
Lisa, V.
Bacakova, L.
Powiązania:
https://bibliotekanauki.pl/articles/285409.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
metal coating
gold film
carboranethiol
cell adhesion
cell spreading
cell proliferation
biomaterials
tissue engineering
surgical implants
Opis:
Metal surfaces have become important over the last decade for potential surgical implants, and within this context we present here a study of the cell growth on modified gold surfaces. Gold films, deposited on glass plates and annealed with a hydrogen flame, were modified with four different carboranethiol derivatives: 1-(HS)-1,2-C2B10H11 (A), 1,2-(HS)2-1,2-C2B10H10 (B), 9,12-(HS)2-1,2-C2B10H10 (C) and 1,12-(HS)2-1,12- C2B10H10 (D). The materials engendered from these modifications were used to investigate the adhesion and growth of rat aortic smooth muscle cells cultured on these surfaces in a DMEM medium with 10% of fetal bovine serum. One day after seeding, the highest number of initially adhered cells was found on the surface of a bare gold film. However, three days after seeding, the number of cells on carboranethiol-modified gold samples B, C and D was significantly higher than the number on a bare gold film. After seven days, the number of cells on a bare gold film and on gold films modified with derivatives A, B and D was very similar, but the surface of a gold film modified with derivative C exhibited a significantly smaller number of cells. This may be explained by the exposure of the CH vertices of the carborane cluster, which are more acidic than the BH vertices exposed toward the cells in either A or B.
Źródło:
Engineering of Biomaterials; 2008, 11, no. 81-84; 117-119
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vascular smooth muscle cells in cultures on low density polyethylene modified with plasma discharge and biofunctionalization
Autorzy:
Parizek, M.
Kasalkova, N.
Bacakova, L.
Kolarova, K.
Lisa, V.
Svorcik, V.
Powiązania:
https://bibliotekanauki.pl/articles/285087.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ar plasma discharge
biomaterials
low-density polyethylene
cell adhesion
cell proliferation
grafting
tissue engineering
vascular smooth muscle cells
Opis:
Low density polyethylene (LDPE) was modified by an Ar plasma discharge and then grafted with glycine (Gly), bovine serum albumin (BSA) or polyethylene glykol (PEG). Some plasma-treated samples and samples grafted with BSA were exposed to a suspension of colloidal carbon particles (C, BSA+C). Pristine LDPE and tissue culture polystyrene dishes (PSC) were used as control samples. The materials were seeded with rat aortic smooth muscle cells and incubated in a medium DMEM with 10% of fetal bovine serum. On day 1 after seeding, the cells on LDPE modified with plasma only, Gly, BSA and BSA+C adhered in similar numbers as on PSC, while the values on non-modified and PEG-modified samples were significantly lower. On day 5, the highest cell numbers were found again on LDPE with Gly, BSA and BSA+C. On day 7, the highest number of cells was found on LDPE modified only with plasma. The latter cells also dis-played the largest cell spreading area. The increased cell colonization was probably due to the formation of oxygen-containing chemical functional groups after plasma irradiation, and also due to positive effects of grafted Gly, BSA and BSA in combination with colloidal C particles.
Źródło:
Engineering of Biomaterials; 2009, 12, no. 89-91; 25-28
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The adhesion and growth of vascular smooth muscle cells in cultures on carboranethiol-modified gold films
Autorzy:
Parizek, M.
Base, T.
Londesborough, M. G. S.
Lisa, V.
Bacakova, L.
Powiązania:
https://bibliotekanauki.pl/articles/286249.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
implanty chirurgiczne
biomateriały
powłoki metalowe
inżynieria materiałowa
metal coatings
gold film
carboranethiol
cell adhesion
cell spreading
cell proliferation
biomaterials
tissue engineering
surgical implants
Opis:
Metal surfaces have become important over the last decade for potential surgical implants, and within this context we present here a study of the cell growth on modified gold surfaces. Gold films, deposited on glass plates and annealed with a hydrogen flame, were modified with four different carboranethiol derivatives: 1-(HS)-1,2-C2 B10H11(A), 1,2-(HS)2-1,2-C2B10H10(B), 9,12-(HS)2-1,2-C2B10H10(C) and 1,12-(HS)2-1,12- C2B10H10(D). The materials engendered from these modifications were used to investigate the adhesion and growth of rat aortic smooth muscle cells cultured on these surfaces in a DMEM medium with 10% of fetal bovine serum. One day after seeding, the highest number of initially adhered cells was found on the surface of a bare gold film. However, three days after seeding, the number of cells on carboranethiol-modified gold samples B, C and D was significantly higher than the number on a bare gold film. After seven days, the number of cells on a bare gold film and on gold films modified with derivatives A, B and D was very similar, but the surface of a gold film modified with derivative C exhibited a significantly smaller number of cells. This may be explained by the exposure of the CH vertices of the carborane cluster, which are more acidic than the BH vertices exposed toward the cells in either A or B.
Źródło:
Engineering of Biomaterials; 2008, 11, 75; 6-8
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improved adhesion and growth of vascular smooth muscle cells in cultures on polyethylene modified by plasma discharge
Autorzy:
Parizek, M.
Kasalkova, N.
Bacakova, L.
Kolarova, K.
Lisa, V.
Svorcik, V.
Powiązania:
https://bibliotekanauki.pl/articles/284295.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
biomateriały
inżynieria tkankowa
Ar plasma discharge
high density and low density polyethylene
cell adhesion
cell proliferation
vascular smooth muscle cells
biomaterials
tissue engineering
Opis:
The attractiveness of synthetic polymers for cell colonization can be affected by physical and chemical modification of the polymer surface. In this study, high density polyethylene (HDPE, m.w. 0.952g/cm3) and low density polyethylene (LDPE, m.w. 0.922g/cm3) were modified by an Ar plasma discharge using Balzers SCD 050 device (exposure time 10, 50, 150 and 400 seconds, discharge power 1.7W). The material was then seeded with rat aortic smooth muscle cells (RASMC; passages 8 to 9, 17 000 cells/cm3) and incubated in a DMEM medium with 10% of fetal calf serum. On day 1 after seeding, the number of initially adhered cells was significantly higher on all modified HDPE and LDPE samples. On day 2, this difference persisted in HDPE, whereas in LDPE only the values on the samples modified by 150 and 400 seconds were significantly higher. On the 5th and 7th day, there were no significant differences in cell number among all LDPE samples. However, on the HDPE foils, significant differences were still apparent on the samples modified for 400 seconds. The cell spreading areas measured on day 1 after seeding were significantly larger on all modified LDPE samples, and, on day 2, on the HDPE samples exposed for 150s. The increased cell colonization was probably due to the formation of oxygen-containing chemical functional groups in the polymer. These results suggest that the responsiveness of the cell to the changes in physiochemical surface properties was more pronounced in HDPE than in LDPE. On both types of polyethylene, the most appropriate exposure time for the enhancement of cell adhesion and growth seemed to be 150 and 400 seconds.
Źródło:
Engineering of Biomaterials; 2007, 10, no. 67-68; 1-4
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies