Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "system sygnalizacji pożarowej" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Problems of diagnosing fire alarm systems in transport facilities
Problemy diagnostyki systemów sygnalizacji pożarowej w obiektach transportowych
Autorzy:
Tatko, Sebastian
Hładun, Sebastian
Paś, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/2200278.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Technologiczno-Humanistyczny im. Kazimierza Pułaskiego w Radomiu
Tematy:
fire alarm system
operation
supervision
system sygnalizacji pożarowej
eksploatacja
dozorowanie
Opis:
The publication presents problems concerning to the implementation of the diagnosis process in the FAS with different functional structures supervising fire safety in transport facilities. The implementation of this process and the test results should be visualized at the FAC installation site (LCD panel) and sent via two independent ICT channels to the ARC. The results of diagnostic tests will enable immediate renewal of the system, and the remote service located in ARC has the ability to identify the type of inoperability and start repair using spare parts from a handy warehouse. This approach makes it possible to rationalize the value of the FAS readiness indicator in transport facilities.
W publikacji zaprezentowano problematykę dotyczącą realizacji procesu diagnozowania w SSP o różnych strukturach funkcjonalnych nadzorujących bezpieczeństwo pożarowe w obiektach transportowych. Realizacja tego procesu oraz wyniki badań powinny być zobrazowane w miejscu zainstalowania CSP (panel LCD) oraz przesyłane dwoma niezależnymi kanałami teleinformatycznymi do ACO. Wyniki badań diagnostycznych umożliwią podjęcie natychmiastowej odnowy systemu, a serwis zdalny znajdujący się w ACO ma możliwość identyfikacji rodzaju niezdatności i podjęcia naprawy z wykorzystaniem części zapasowych z podręcznego magazynu. Takie podejście umożliwia racjonalizacje wartości wskaźnika gotowości SSP w obiektach transportowych.
Źródło:
Journal of Automation, Electronics and Electrical Engineering; 2022, 4, 2; 39--43
2658-2058
2719-2954
Pojawia się w:
Journal of Automation, Electronics and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of the process of selected fire signaling systems
Modelowanie procesu eksploatacji wybranego systemu sygnalizacji pożarowej
Autorzy:
Paś, Jacek
Klimczak, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/329382.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
reliability
fire alarm systems
operation
model
niezawodność
system sygnalizacji pożarowej
eksploatacja
Opis:
The article presents a selected model of the operation process of the fire system (FSS). The developed fire scenario for the selected building object is possible for practical implementation only with the use of an appropriate functional structure FSS and technical devices from which the system is built with the appropriate reliability and technical parameters. Practical implementation of FSS in a transport facility is the use of elements, devices, fire panels, detectors, etc., which form a specific connection structure. The use of appropriate technical solutions in the system - redundancy, booking and the principle of safe damage causes that FSS has an optimal structure in terms of reliability. The article presents the selected technical structure of the FSS, which was described by means of the exploitation process graph, taking into account the actual damage intensities and the renewal times for selected devices included in the system. A constant intensity of damage was assumed in the FSS operation process due to the initial aging of individual devices that takes place in the production plant. The development of a model of exploitation process for selected operational states and a computer simulation of a selected FSS enables determination of reliability indicators.
W artykule przedstawiono wybrany model procesu eksploatacji systemu sygnalizacji pożarowej (SSP). Opracowany scenariusz pożarowy dla wybranego obiektu budowlanego możliwy jest do realizacji tylko z zastosowaniem odpowiedniej struktury funkcjonalnej SSP i urządzeń technicznych z których zbudowany jest system. System powinien się posiadać odpowiednie parametry niezawodnościowo-techniczne. Realizacja praktyczna SSP w obiekcie to wykorzystanie elementów, urządzeń, central sygnalizacji pożarowej, czujek, itd., które połączone instalacją tworzą określoną strukturę o wyznaczonych relacjach przez projektanta. Stosowanie odpowiednich rozwiązań technicznych w systemie - tj. rezerwowania i zasady bezpiecznego uszkodzenia powoduje iż SSP posiada optymalną strukturę pod względem niezawodności. W artykule przedstawiono wybraną strukturę techniczną SSP, którą opisano za pomocą grafu procesu eksploatacji uwzględniając rzeczywiste intensywności uszkodzeń i czasy odnowy dla wybranych urządzeń które wchodzą w skład systemu. Założono stałą intensywność uszkodzeń w procesie eksploatacji SSP ze względu na wstępne starzenie poszczególnych urządzeń które ma miejsce w zakładzie produkcyjnym. Opracowany model procesu niezawodnościowo-eksploatacyjnego dla wybranych stanów i symulacja komputerowa w wybranej aplikacji umożliwiają wyznaczenie odpowiednich wskaźników użytkowania SSP.
Źródło:
Diagnostyka; 2019, 20, 4; 81-88
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies