Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "HEC" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Hydrological modelling of wadi Ressoul watershed, Algeria, by HEC-HMS model
Hydrologiczne modelowanie zlewni rzeki Ressoul w Algierii za pomocą modelu HEC-HMS
Autorzy:
Skhakhfa, I. D.
Ouerdachi, L.
Powiązania:
https://bibliotekanauki.pl/articles/293098.pdf
Data publikacji:
2016
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
Annaba
calibration
flood modelling
HEC-HMS
validation
kalibracja
modelowanie powodzi
testowanie
Opis:
This study presents a flood estimation model for wadi Ressoul in El Berda watershed, north east of Algeria. To ensure the overall consistency of simulated results, it is necessary to develop a validation process, particularly in regions where data are scarce or limited and unreliable. To this we must calibrate and validate the model over the hydrograph as measured at the output. Calibration and validation processes were carried out using different sets of data (CN, SCS Lag and Muskingum K). Evaluation on the performance of the developed flood model derived using HEC-HMS (hydrologic modelling system) yield a correlation coefficient R2 close to 1 and the Nash–Sutcliffe efficiency. We limit ourselves to modelling flood of short duration for which the process of evapotranspiration is negligible. Several events have been tested, including two to calibrate and one to validate the model. So it can be said that using the HEC-HMS model had the highest efficiency in with the values of these parameters calibrated, based on objective functions (percent error in peaks), with 8.8 percent difference between of observed and simulated discharges with R2 value is 0.87 and the Nash-Sutcliffe efficiency value is 0.99.
W publikacji przedstawiono model oceny powodzi opracowany dla rzeki Rassoul w zlewni El Berda w północno-wschodniej Algierii. Aby zapewnić spójność wyników symulacji, należy przeprowadzić proces sprawdzenia modelu, szczególnie w odniesieniu do regionów, w których dane są skąpe lub ograniczone i mało wiarygodne. W tym celu należało kalibrować model i dokonać jego potwierdzenia na podstawie danych hydrograficznych. Procesy kalibracji i testowania przeprowadzono z użyciem różnych zestawów danych (CN, SCS Lag i Muskingum K). W wyniku oceny zachowania skonstruowanego modelu HEC-HMS uzyskano współczynnik determinacji R2 bliski 1 i dobry współczynnik efektywności Nasha–Sutcliffa. Autorzy ograniczyli się do modelowania powodzi o krótkim czasie trwania, gdy można pominąć ewapotranspirację. Testowano kilka zdarzeń, w tym dwa w celu kalibracji i jedno w celu potwierdzenia modelu. Można stwierdzić, że model HEC-HMS ma najwyższą wydajność opartą na obiektywnych funkcjach (procent błędu w szczytach fali) wyrażoną 8,8-procentową różnicą między obserwowanym i symulowanym odpływem, gdy R2 = 0,87 i wartość współczynnika efektywności Nasha–Sutcliffa wynosi 0,99.
Źródło:
Journal of Water and Land Development; 2016, 31; 139-147
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of two loss methods for estimation of surface runoff in Zaafrania urban catchment, North-East of Algeria
Ocena dwóch metod szacowania spływu powierzchniowego w miejskiej zlewni Zaafrania, północnowschodnia Algieria
Autorzy:
Dahdouh, Y.
Ouerdachi, L.
Powiązania:
https://bibliotekanauki.pl/articles/292332.pdf
Data publikacji:
2018
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
Green–Ampt method
HEC-HMS method
rainfall-runoff modelling
SCS-CN
surface runoff
urban catchment
metoda Green–Ampt
metoda HEC-HMS
modelowanie relacji opad–odpływ
spływ powierzchniowy
zlewnia miejska
Opis:
Surface runoff is a major problem in urban catchments; its generation is always related to the amount of effective rainfall dropped over the surface, however in urban catchments the process is considerably altered by the emergence of impervious areas. In this study the Soil Consevation Service – curve number (SCS-CN) and the Green–Ampt loss methods were used in rainfall-runoff modelling in the Zaafrania urban catchment which is located in Annaba city in the north east of Algeria. The two loss methods were carried out within Hydrologic Engineering Center – Hydrologic Modelling System (HEC-HMS), the choice of the appropriate method for simulating runoff hydrographs in the study area was made by comparing the simulated hydrographs versus observed data using visual inspection and statistical analysis. The results indicate that SCS-CN loss method fit better in the case of 100 years return period NSE (0.462) than in 10 years NSE (0.346) and the results of calibration of Green– Ampt loss method for the 100 years return period NSE (0.417) provide best fit than the case of 10 years NSE (0.381). Furthermore, the results of both return periods (10 and 100 years) of SCS-CN loss method provide best fit than the results of return periods (10 and 100 years) of Green–Ampt loss method. It could be concluded that SCS-CN method is preferred to the Green–Ampt method for event based rainfall-runoff modelling.
Spływ powierzchniowy jest głównym problemem w miejskich zlewniach. Spływ jest zawsze uzależniony od opadu, jednak w miejskich zlewniach proces ulega znaczącej modyfikacji z powodu obecności powierzchni nieprzepuszczalnych. W badaniach prezentowanych w niniejszej pracy zastosowano dwie metody – SCS-CN (ang. Soil Coservation Service – curve number) i Green–Ampt do modelowania relacji opad–odpływ w miejskiej zlewni Zaafrania na terenie miasta Annaba na północnym wschodzie Algierii. Obie metody realizowano w ramach modelu HEC-HMS. Odpowiednią metodę symulowania hydrogramu odpływu dobrano na podstawie wizualnej oceny i analizy statystycznej. Wyniki dowodzą, że metoda SCS-CN dawała lepsze dopasowanie w przypadku stuletniego okresu powtarzalności (NSE = 0,462) niż w przypadku okresu dziesięcioletniego (NSE = 0,346). Wyniki kalibracji metodą Green–Ampt zapewniały lepsze dopasowanie dla stuletniego niż dla dziesięcioletniego okresu powtarzalności (NSE odpowiednio 0,417 i 0,381). Ponadto wyniki metody SCS-CN dla obu okresów (10 i 100 lat) wykazywały lepsze dopasowanie niż wyniki uzyskane za pomocą metody Green– Ampt dla tych okresów. Można wnioskować, że metoda SCS-CN ma przewagę nad metodą Green–Ampt w modelowaniu relacji opad–odpływ w odniesieniu do poszczególnych zdarzeń.
Źródło:
Journal of Water and Land Development; 2018, 36; 37-43
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies