Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "current transducer" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
New Quality of Current Measurement in Power Switchgear with the Use of PCB Sensors
Nowa jakość pomiaru prądów za pomocą sensorów PCB w rozdzielnicach energetycznych
Autorzy:
Lisowiec, A.
Nowakowski, A.
Wlazło, P.
Powiązania:
https://bibliotekanauki.pl/articles/397373.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
przetwornik prądowy
cyfrowe przetwarzanie sygnałów
technologia PCB
current transducer
digital signal processing
PCB technology
Opis:
In the paper separable and non-separable current transducers using printed circuit board technology have been presented. The transducers are characterized by a measurement range from a fraction of an ampere to 100 kA, perfect linearity and measurement bandwidth from 10 Hz to 20 kHz. The PCB technology makes it possible to obtain very high repeatability of transducer electrical parameters. The spread in the value of the most important parameter – the sensitivity, in a typical production lot is less than 0.5%. The same transducer can work simultaneously with protection device and power meter. The wide bandwidth of the transducer made in PCB technology enables its use in power quality analyzers. The additional advantage of PCB technology is the possibility to integrate the transducer with signal processing circuits. The construction of separable current transducer using PCB technology makes it possible to install it over the wire with measured current without disconnecting primary circuits. Transducers made in PCB technology have very symmetric secondary winding which is a crucial factor in ensuring that the measurement results are largely independent of the external magnetic fields not associated with the measured current.
W artykule przedstawiono rozłączalne i nierozłączalne bezrdzeniowe przetworniki prądowe wykonane w technologii wielowarstwowych obwodów drukowanych (PCB). Przetworniki te charakteryzują się zakresem pomiaru od ułamka ampera do 100 kA, doskonałą liniowością oraz pasmem częstotliwości od 10 Hz do 20 kHz. Zastosowana technologia PCB umożliwia uzyskanie dużej powtarzalności parametrów elektrycznych przetworników. Rozrzut najważniejszego parametru przetwornika, jakim jest współczynnik przetwarzania (czułość), w typowej partii produkcyjnej jest na poziomie poniżej 0,5%. Dzięki temu ten sam przetwornik może współpracować z urządzeniami zabezpieczeniowymi oraz urządzeniami pomiarowymi służącymi do rozliczania energii. Uzyskana szerokość częstotliwościowego pasma pomiarowego umożliwia zastosowanie tych przetworników prądu w analizatorach jakości energii. Zaletą zastosowania technologii PCB jest możliwość integracji przetworników prądowych z układami przetwarzania sygnałów. Konstrukcja rozłączalnego przetwornika prądowego wykonanego w technologii PCB umożliwia zainstalowanie go na przewodzie z mierzonym prądem bez rozłączania prądowych obwodów pierwotnych. Przetworniki wykonane w technologii PCB charakteryzują się doskonałą symetrią uzwojenia, dzięki temu wynik pomiaru za pomocą przetwornika jest w dużej mierze niezależny od zewnętrznych pól magnetycznych niezwiązanych z mierzonym prądem.
Źródło:
Acta Energetica; 2015, 2; 59-67
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Intelligent Current Sensors as Part of Smart Grid Network
Inteligentne sensory prądowe jako element sieci Smart Grid
Autorzy:
Nowakowski, A.
Wlazło, P.
Przybysz, R.
Powiązania:
https://bibliotekanauki.pl/articles/397550.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
smart grid
intelligent current sensors
autonomous power supply
current transducer
time synchronization
Smart Grid
inteligentny sensor prądu
zasilanie automatyczne
przetwornik prądowy
synchronizacja czasowa
Opis:
The continuous development of the ITC systems, especially industrial Ethernet network using the IEC 61850 protocol allows to building a distributed sensor networks for control and monitor temporary states of the power infrastructure. In the paper the construction of the intelligent current sensors, Measurement Units (MU) for the Smart Grid network has been presented. In the paper the circuit diagram of sensor and synchronization method of the analog to digital converter based on the UTC timestamps has been described. The presented method allows to synchronize intelligent current sensors with an accuracy better than 1 μs. The presented innovative synchronization method is characterized by a high level of resistance to disappearance and attack of the reference time signal. The measuring device MU design is based on the embedded Linux-platform and as a sensing element used air core current transducers based on Rogowski coil. The connection between the current transducers and the central unit is made using a fiber optic link. Built-in IEC-61850 server provides a real-time measurement value of the True RMS, harmonics spectrum and samples value. The intelligent current transducers in addition to being used in the MUs create also new possibilities in the substation construction like the possibility to place the Autonomous Sensors in large distance from Intelligent Electronic Devices that are located in the substation.
Ciągły rozwój systemów teleinformatycznych, zwłaszcza przemysłowych sieci Ethernet wykorzystujących protokół IEC-61850, pozwala na budowę rozproszonych sieci sensorycznych do kontrolowania i monitorowania chwilowego stanu pracy infrastruktury elektroenergetycznej. W prezentowanej publikacji przedstawiono budowę inteligentnego sensora prądu jako jednostki Measurement Units (MU) sieci Smart Grid. Omówiono budowę poszczególnych bloków sensora oraz sposób synchronizacji przetwornika analogowo- cyfrowego za pomocą wzorcowego sygnału znaczników czasu UTC. Przedstawiona metoda pozwala na synchronizację inteligentnych sensorów prądowych z dokładnością lepszą od 1 μs. Przedstawiona innowacyjna metoda i układ synchronizacji charakteryzuje się wysokim poziomem odporności na zanik i atak na referencyjny sygnał czasu. Budowa urządzenia pomiarowego MU została oparta na platformie z wbudowanym systemem operacyjnym Linux, a jako element pomiarowy prądu wykorzystano bezrdzeniowy przetwornik pracujący na zasadzie cewki Rogowskiego. Połączenie między przetwornikiem prądowym a jednostką centralną jest wykonane za pomocą łącza światłowodowego. Wbudowany serwer IEC-61850 udostępnia dane o wartościach skutecznych i harmonicznych oraz próbkach sygnału. Zaprezentowane rozwiązanie inteligentnych przetworników prądu oprócz zastosowania jako układu MU daje również nowe możliwości w konstrukcji rozdzielni, m.in. umożliwia umieszczenie autonomicznych sensorów prądowych ze znacznej odległości od innych urządzeń rozdzielni i sterowników polowych.
Źródło:
Acta Energetica; 2015, 2; 48-57
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies