Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "exchanger" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Feasibility of using heat-recovery exchangers in livestock buildings at a site at a specific altitude with a specific average outdoor air temperature
Autorzy:
Sleger, V.
Neuberger, P.
Polak, M.
Powiązania:
https://bibliotekanauki.pl/articles/62353.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
feasibility
heat-recovery exchanger
livestock building
outdoor air temperature
climate condition
Czech Republic
agriculture
air temperature
weather station
ventilation
air exchange
heat exchanger
Opis:
The installation of an energy-saving facility must be preceded by analysis of its financial effectiveness. Among methods enabling such evaluation is the basic net profit calculation method. For this, the annual consumption of electricity for ventilation or of thermal energy for heating must be determined. The calculation formula uses the sum of energies for temperatures within the range from the calculation temperature for the area in question to the long-term average of the maximum temperature at the site, or to the temperature at which the heating power is zero. It is necessary to know the summary time of occurrence of a given temperature during a year. The site data can only be assessed based on long-term meteorological information. In fact, data used by current national standards to describe climatic conditions in the Czech Republic are from the years 1901 to 1950. The dependence of the average yearly temperature on altitude is shown in Fig. 1 for the 1961 1990 and 1991 2000 periods. It is evident that the average temperatures for the latter period are nearly 0.6 K higher than those for the former period, irrespective of the altitude. In this paper the climatic conditions are assessed based on daily data measured throughout the period from 1 January 1991 to 31 December 2000. Weather stations were selected so as to achieve a uniform coverage and continuity of measurement at each site (as far as possible). All the stations lie in the Czech Republic between 48.8° and 50.8° north latitude at altitudes from 158 m to 1324 m. It was the objective of this examination, based on the meteorological data collected to calculate the average number of days and hours during which the temperature during the year is lower than a specific limiting level, in dependence on the average yearly temperature of the site. Fig. 3 shows the average number of days in a year during which a temperature lower than a selected limiting level occurs, as calculated for the 1991 2000 period. The results are presented for 4 areas with average yearly temperatures of 6 °C 7 °C, 7 °C 8 °C, 8 °C 9 °C, and 9 °C 10 °C, respectively. The graphs enables us to ascertain the number of days during which a heating facility is in operation if the facility is activated by outdoor air temperature decrease to below a specific limiting level. If a typical daily temperature wave is considered, the method makes it possible to estimate the number of hours during which the air temperature is lower than the limiting level chosen. The difference between the data for various limiting levels allows us, for an area with a specific average yearly temperature to ascertain the time of occurrence of outdoor temperature within various ranges. The results of calculations are shown in Fig. 4 and Table 1. The method applied enables underlying data to be prepared for the assessment of energy demands for air heating at a given site and for estimation of the energy savings that could be achieved by installing economical air heating facilities in livestock buildings.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2009, 07
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Egzergia cieplnych strumieni wymienników rekuperatorowych. Cz. II. Badania
Egzergy of thermal streams in recuperator exchangers. Part II. Tests
Autorzy:
Neuberger, P.
Adamovský, D.
Rutkowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/287466.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
powietrze
wymiennik ciepła
anergia
egzergia
energia
air
heat exchanger
anergy
egzergy
energy
Opis:
W artykule przeanalizowano wpływ temperatur wejścia na egzergię strumienia ciepła traconego, termiczną i egzergetyczną sprawność płytowego wymiennika rekuperatorowego oraz cieplnych wymienników grawitacyjnych typu powietrze - powietrze, przy stałych objętościowych strumieniach ogrzewanego i chłodzonego powietrza. Wyniki badań oraz ich analiza potwierdziły zależność między egzergią traconego strumienia ciepła a wartościami temperatur wejścia, wzrost egzergetycznej sprawności wykorzystania ciepła z ochładzanego powietrza oraz spadek sprawności przekazywania ciepła ochładzanego do ogrzewanego powietrza wraz ze wzrostem różnicy temperatur wejścia. Ponadto sformułowano zależność miedzy temperaturową a całkowitą sprawnością.
The paper contains an analysis of input temperature effect on stream egzergy of heat being lost, thermal and egzergetic efficiency of plate-type recuperator exchanger and thermal exchangers (gravitational air - air type), at constant volumetric streams of heated and cooled air. Research results and their analysis have proved relation between egzergy of heat stream being lost and input temperature values, increase of egzergetic efficiency of utilizing heat from cooled air, and drop of efficiency of heat transfer between cooled and heated air with increasing difference between input temperature values. Moreover, the research allowed to define relation between temperature efficiency and total efficiency.
Źródło:
Inżynieria Rolnicza; 2006, R. 10, nr 12(87), 12(87); 399-407
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Verification of the effects of the secondary heat recovery from ventilation air in an animal house for the fattening of broiler chickens
Autorzy:
Adamovsky, R.
Adamovsky, D.
Kara, J.
Neuberger, P.
Powiązania:
https://bibliotekanauki.pl/articles/61735.pdf
Data publikacji:
2008
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
verification
secondary heat recovery
ventilation
air
animal house
fattening
broiler chicken
heat exchanger
gravitation thermal pipe
exchanger efficiency
thermal balance
specific energy consumption
energy consumption
heat recovery system
Opis:
This paper presents results of the verification of a heat exchanger composed of gravitation thermal pipes installed in a broiler chicken feeding facility. The objective of the study was to verify the possibility of the application of a power management system including a heat recovery system in a heavy-duty environment of a broiler chicken fattening facility and to specify effects of the system upon the specific consumption of energy for space heating and ventilation of the animal house. The calculation of the thermal balance of the animal house documents that the power management system that includes a heat recovery exchanger unit may reduce the thermal capacity of external sources of heat in the animal house by 26.5% even when subject to extreme conditions and at the atmospheric temperature of -12°C and the age of chickens being 1 day. The results of the metering and calculations of the efficiency have proven that the heat exchanger reaches the operational efficiency of 10–47% and thermal efficiency of 20–80% even during the most demanding operational first twenty days of the breeding cycle of broiler chickens. The specific consumption of energy for space heating and ventilation related to 1 kg of the live weight of chicken in the animal house facility A provided with a heat recovery exchanger unit at the average atmospheric temperature during the cycle being 4.3°C amounted to 278.5 Wh. In the animal house B as not provided with the heat recovery exchanger units hosting the same number of chickens and provided with the same process and thermal loss due heat transmission through peripheral structures being one half compared to the animal house A, the specific consumption of energy per 1 kg of the live weight of chicken was 420.5 Wh.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2008, 06
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Egzergia cieplnych strumieni wymienników rekuperatorowych. Cz. I. Teoria
Egzergy of thermal streams in recuperator exchangers. Part I. Theory
Autorzy:
Neuberger, P.
Adamovský, D.
Rutkowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/287468.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
powietrze
wymiennik ciepła
anergia
egzergia
energia
air
heat exchanger
anergy
egzergy
energy
Opis:
W artykule przedstawiono analizę teoretyczną nieodwracalnych przemian termodynamicznych, strat egzergii oraz sprawności termicznej i egzergetycznej w wymiennikach: płytowym i grawitacyjnym typu powietrze - powietrze. W oparciu o znane prawa termodynamiki procesów nieodwracalnych oraz bilans egzergetyczny wyprowadzono zależności, pozwalające na określenie wpływu temperatur wejścia na analizowane wielkości.
The paper presents theoretical analysis of irreversible thermodynamic processes, egzergy losses, and thermal and egzergetic efficiency in the following exchangers: plate-type and gravitational air - air type. Known laws of irreversible processes thermodynamics and egzergetic balance allowed to derive relations, which make it possible to determine the effect of input temperatures on analysed quantities.
Źródło:
Inżynieria Rolnicza; 2006, R. 10, nr 12(87), 12(87); 391-397
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analyzing temperature changes in the ground massif with a horizontal heat exchanger in the course of the heating season
Autorzy:
Adamovsky, R.
Neuberger, P.
Sed'ova, M.
Powiązania:
https://bibliotekanauki.pl/articles/62442.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
temperature change
ground massif
horizontal heat exchanger
heating season
heat pump
ground source heat pump
heat transfer
energy potential
ground temperature
temperature distribution
Opis:
The article is devoted to temperature changes in the ground massif with the horizontal heat exchanger as an energy source for a heat pump. The article was aimed at analyzing temperature changes in the ground massif with the horizontal heat exchanger at the beginning, in the course of and at the end of the heating season. Another aim was to analyze temperature differences in the area of the horizontal exchanger and the reference lot. The heat flow utilized in the evaporator of heat pump was extracted from the ground exchanger (nominal output at the condenser was 10.5 kW). Temperatures of the ground massif with the horizontal heat exchanger were measured in its plane in depths of 0.75 m, 0.5 m and 0.25 m. The temperature inside the ground massif on the reference lot and ambient parameters were measured as well. It is obvious that the difference of energetic potentials inside the ground massif with the heat exchanger and on the reference lot is insignificant at the beginning of the heating season. During the heating season, the difference of ground massif energetic potentials increases; at the end it is constant. The difference of temperatures in horizontal planes was not significant at the beginning of the heating season; however, it gradually increased. Maximum differences were detected in the area of the heat exchanger. In higher strata, the difference between temperatures decreases. During a major part of the heating season, temperatures at pipes of the ground exchanger were negative. This fact affected amounts of heat extracted from the ground massif.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2010, 11
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature changes in heat pump horizontal ground source
Autorzy:
Adamovsky, R.
Neuberger, P.
Sed'ova, M.
Powiązania:
https://bibliotekanauki.pl/articles/60337.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
temperature change
heat pump
ground massif
horizontal heat exchanger
heat potential
soil
thermal potential
heating period
ground temperature
temperature distribution
heat transfer
energy conservation
Opis:
The paper deals with assessment of thermal fields and temperature changes in ground massif with horizontal heat exchanger used as a heat source for a heat pump. Temperatures in the zone of the horizontal ground exchanger are compared with temperatures in a reference land. Changes of heat potential of the soil during the heating period are also assessed. Possibilities of recovery of thermal potential of the ground massif when utilizing vertical and horizontal exchangers are analyzed in the opening part of the paper. The results of the first verification indicated that average temperatures in the horizontal planes of the ground massif did not differ considerably with distance from the exchanger tube. Differences in average temperatures in reference and experimental lands confirmed sufficient heat potential of the ground massif even at the peak of the heating period. The differences in average temperatures reached up to 6.51 K in the end of the heating period while at the beginning of the heating period, the differences in average temperatures dropped to 1.35 K. The differences between maximum and minimum temperatures in the zone of the ground exchanger reached up to 1.9 K at the peak of the heating period and rose to 3.9 K at the beginning and end of the heating period. The first results of our measurements indicate the necessity of accumulation of thermal energy in the soil massif in the summer period like in case of the vertical exchangers.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2009, 07
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies