Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Pluciennik, Z." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
COD fractions in raw and mechanically treated wastewater
Frakcje ChZT w ściekach surowych i mechanicznie oczyszczonych
Autorzy:
Płuciennik-Koropczuk, E.
Sadecka, Z.
Myszograj, S.
Powiązania:
https://bibliotekanauki.pl/articles/396162.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
raw wastewater
COD fractions
ASM models
mechanical treatment
substances biodegradable
organic substances
ścieki surowe
Frakcje ChZT
modele ASM
oczyszczanie mechaniczne
substancje biodegradowalne
substancje organiczne
Opis:
The paper presents results of studies concerning the designation of COD fraction in the raw and mechanically treated wastewater in different year seasons. The research object was a mechanical-biological wastewater treatment plant with the output of >40 000 P.E., located in western Poland. The results of COD fraction in the raw wastewater were compared with data received in the ASM models. Methodology for determining the COD fraction was based on the guidelines ATV - A 131. During the research following fractions were determined: particulate slowly biodegradable substrates (Xs), soluble readily biodegradable substrates (Ss), inert particulate organic material (Xr) and inert soluble organic material (Sr). Soluble and particulate components were differentiated by filtration through 0.45μm membrane filters. The percentage of each fraction in total COD determined on the real concentration in raw wastewater are different from data reported in the literature.
W artykule przedstawiono wyniki badań dotyczące frakcji ChZT w ściekach surowych i mechanicznie oczyszczonych w piaskowniku. Badania prowadzono w mechaniczno-biologicznej oczyszczalni ścieków o wielkości>40 000 RLM, zlokalizowanej w zachodniej Polsce. Próbki do badań pobierano w różnych porach roku. Metodyka wyznaczania frakcji ChZT została opracowana w oparciu o wytyczne ATV-131. Podczas badań określono następujące frakcje: substancje organiczne w zawiesinie, biologicznie wolno rozkładalne (Xs), rozpuszczone substancje organiczne, biologicznie łatwo rozkładalne, (Ss), substancje organiczne w zawiesinie, biologicznie trudno rozkładalne (Xr) i rozpuszczone substancje organiczne, biologicznie nierozkładalne (Sr). Rozdziału frakcji rozpuszczonych i w zawiesinie dokonano przez filtrację próbek ścieków przez filtry membranowe o wielkości porów 0,45 μm. Wyniki badań wykazały, że zarówno w ściekach surowych jak i oczyszczonych mechanicznie udział frakcji biodegradowalnych wynosił ok. 80% całkowitego ChZT. Oczyszczanie ścieków w piaskowniku spowodowało obniżenie stężenia zanieczyszczeń organicznych o ok. 30% oraz wpływało na zmiany w udziale frakcji rozpuszczonych i w zawiesinie. Wartości procentowego udziału frakcji XS i XI w ściekach po piaskowniku zmalały, podczas gdy wartości procentowego udziału frakcji Ss i Sr wzrosły, w stosunku do ich udziału w ściekach surowych. Udział procentowy frakcji ChZT w ściekach surowych wyznaczony w badaniach różni się od danych zawartych w modelach ASM1 i ASM 2.
Źródło:
Civil and Environmental Engineering Reports; 2013, 11; 101-113
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ diazynonu (Basudin 25EC) na proces fermentacji metanowej komunalnych osadów ściekowych
Impact of Diazinon (Basudin 25EC) on the Anaerobic Digestion Process of Municipal Sewage Sludge
Autorzy:
Sadecka, Z.
Myszograj, S.
Sieciechowicz, A.
Płuciennik-Koropczuk, E.
Powiązania:
https://bibliotekanauki.pl/articles/1818611.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
insektycydy
toksyczność
fermentacja metanowa
biogaz
insecticides
toxicity
anaerobic digestion process
biogas
Opis:
The process of methane fermentation is a labile process, sensitive to changes in the environment and susceptible to various substances which may turn out to be toxic for anaerobic biocenosis. The process may be inhibited by both the substances supplied together with the substrate and also the products resulting from the decomposition phases. The group of toxic substances which influences the fermentation process comprises heavy metals, organic compounds, ammonia nitrogen, lower organic acids, nitrogen or sulphur compounds, add to this a large group of organic micropollutants such as hormones added to fodder, disinfectants, insecticides, chemotherapeutics, antibiotics or chemical plant protection products which are all overlooked. These compounds, while occurring in the media subjected to anaerobic stabilisation, may cause a decrease in the speed of the process, possibly also causing its disruption. The inhibitory effect of various chemical compounds on the course of the fermentation process may be evaluated on the basis of the characteristics of the microorganism community, dynamics of changes in its structure and activity of the population. The determination of the activity of enzymes participating in the methane fermentation may be used to evaluate the impact of xenobiotics on the fermentation process and the efficiency of methane production. In the operational practice referring to the fermentation equipment, the impact of biotic and abiotic factors may be evaluated on the basis of changes in the process parameters. The changes in the quantity of microorganisms and the low enzymatic activity cause a decrease in the efficiency of biogas production including methane, as well as a reduction in the effectiveness of the process measured by the loss of the content of organic compounds. The paper presents the results of laboratory tests, concerning the effect of diazinon on the course of biogas production in the process of the methane fermentation of municipal sewage sludge. Diazinon is one of the representatives of phosphate insecticides and an active substance of the commercial preparation bearing the name Basudin 25EC. The effect of the preparation on the course of the process of methane fermentation of sewage sludge was studied within a dose range from 0.5 to 30 mg/ dm-3. The characteristic indicators of the course of anaerobic stabilisation of sewage sludge include the quantity and the composition of the fermentation gas in reference to the fermentation temperature and time. Based on the changes of these parameters, the inhibitive effect of diazinon contained in the Basudin 25EC technical preparation was evaluated. The biogas production in sludge with various doses of diazinon was assumed as a measure of toxicity in reference to the control sludge. The results of the studies showed that: Anaerobic microorganisms are characterised by sensitivity to the Basudin 25EC utility preparation (with a content of 25% diazinon). The first symptoms of the inhibition of the fermentation process occurred at doses of the preparation amounting to 0.5, 1 and 2 mg/dm-3. The inhibition is confirmed by a decrease in the biogas production of about 10%. The intensification of inhibition symptoms was evident at doses ranging from 4 to 8 mg/ dm-3. The reduction in biogas production ranged from 13,0–25,0%. In the sludge where the greatest dose of the preparation was applied, that is, 30 mg/ dm-3, the biogas efficiency went down from 522 dm-3/kg of dry matter to 57.0 dm-3/kg of dry matter. A 10 mg/ dm-3 dose of Basudin 25EC, causing a 60% decrease in the efficiency of biogas production (from 522 to 211 dm-3/kg of dry matter) must be regarded as toxic for the process of methane fermentation of municipal sludge sewage.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 2; 931-942
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of the sewer system rinsing on the wastewater composition
Autorzy:
Sadecka, Z.
Płuciennik-Koropczuk, E.
Myszograj, S.
Suchowska-Kisielewicz, M.
Jakubaszek, A.
Powiązania:
https://bibliotekanauki.pl/articles/207804.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
sewers
pollution
sewage
sewage pumping plants
water treatment plants
biological reactor
sewage pollutions
wastewater treatment plants
kanalizacja
ścieki
przepompownie ścieków
stacje uzdatniania wody
reaktor biologiczny
zanieczyszczenia ścieków
oczyszczalnie ścieków
Opis:
The paper presents the results of research on the influence of the operational rinsing of a sewer system on the composition of raw sewage, the effectiveness of the operation of the mechanical part of a wastewater treatment plant and changes in the technological parameters of the biological reactor. The results of the research have shown an increase in sewage pollution during the rinsing of the sewer system. The value of the COD indicator increased from 799 to 1306 mg/dm3, BOD5 from 538 to 1044 mg/dm3, and total suspended solids from 259 to 1508 mg/dm3. The calculations indicate that an increase in the concentrations of pollution during the rinsing of the sewer system requires a high working efficiency of the mechanical part of the wastewater treatment plant. With a low efficiency the volume of the biological reactor can increase even by 30%.
Źródło:
Environment Protection Engineering; 2013, 39, 2; 5-13
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transformations of organic compounds in the open intercepting sewer
Przemiany związków organicznych w otwartym kanale ściekowym
Autorzy:
Myszograj, S.
Sadecka, Z.
Suchowska-Kisielewicz, M.
Płuciennik-Koropczuk, E.
Qteishat, O.
Powiązania:
https://bibliotekanauki.pl/articles/396661.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
biochemical process
dissolved oxygen
COD fraction
open intercepting sewer
cascade
proces biochemiczny
frakcja COD
kanał ściekowy otwaty
kaskadowy przepływ ścieków
Opis:
The paper presents results of studies concerning the designation of COD fraction in the raw wastewater. The test object was open intercepting sewer of Zielona Góra. Methodology for determining the COD fraction was based on the guidelines ATV- A 131. The real concentration of fractions in raw wastewater and the percentage of each fraction in total COD are different from data reported in the literature. The processes occurring in an open interceptor are also influenced by external factors. The most important of them are the ambient temperature and the extent of solar exposure. The changing temperature influences solubility of oxygen and activity of microorganisms. Open space and cascade arrangement of the interceptor decrease the probability of oxygen-free environment. In this case, the dominating significance in the decomposition of organic compounds is to be ascribed to oxygen processes.
Głównym zadaniem sieci kanalizacyjnych jest odbiór i odprowadzenie ścieków do oczyszczalni lub odbiornika. Obecnie coraz częściej sieć kanalizacyjna jest analizowana w aspekcie zachodzących w niej procesów biochemicznych. Kanał doprowadzający ścieki do oczyszczalni można potraktować jak przepływowy odbiornik ścieków i przyjąć, że zachodzą w nim przemiany, których podstawą są procesy samooczyszczania zachodzące w rzekach. Zmiany w składzie ścieków w kanalizacji mogą w istotny sposób wpływać na pracę oczyszczalni i odbiornik ścieków oczyszczonych. W artykule przedstawiono wyniki badań zmian charakterystyki ścieków surowych dopływających do oczyszczalni ścieków kanałem otwartym. Ustalono, że na procesy zachodzące w kolektorze otwartym znaczący wpływ mają czynniki zewnętrzne. Najważniejszym z nich jest temperatura otoczenia i stopień nasłonecznienia. Temperatura ścieków wpływa na rozpuszczalność tlenu w ściekach i aktywność mikroorganizmów. System kaskadowego przepływu ścieków w kolektorze zmniejsza prawdopodobieństwo wystąpienia warunków beztlenowych.
Źródło:
Civil and Environmental Engineering Reports; 2012, 8; 19-28
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies