Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "DF" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Method of Measuring the Distance to an Object Based on One Shot Obtained from a Motionless Camera with a Fixed-Focus Lens
Autorzy:
Murawski, K.
Powiązania:
https://bibliotekanauki.pl/articles/1189717.pdf
Data publikacji:
2015-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
06.30.Bp
07.05.Pj
07.07.Df
Opis:
The paper presents the method of measuring the distance to the object based on digital image processing. The solution is characterized in that the distance measurement to the object is performed by a motionless camera with established and unchanged parameters during measurement. The camera is equipped with a one non-stereoscopic lens. The measured distance is determined on the basis of one view of an object presented on one image. The image is made at a constant and invariant setting of the optical path such as: focus, aperture and focal length.
Źródło:
Acta Physica Polonica A; 2015, 127, 6; 1591-1595
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reconstruction of Lost Fragments of Signal Received from the Wireless Sensor Measuring Fluid Pressure inside the Eye Ball
Autorzy:
Murawski, K.
Grad, L.
Rękas, M.
Powiązania:
https://bibliotekanauki.pl/articles/1189729.pdf
Data publikacji:
2015-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.07.Df
88.80.ht
87.85.Ng
Opis:
The aim of the paper is to present a technique of reconstructing data received from a wireless sensor for measuring intraocular pressure. The algorithm was developed to automatically regenerate samples lost due to fortuitous events in clinical trials. The test consisted in measuring the pressure within 24 h, during which the intraocular pressure curve were determined. The paper also discusses the structure and the physical basis of sensor operation and shows the advantages resulting from its use.
Źródło:
Acta Physica Polonica A; 2015, 127, 6; 1596-1600
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Infrared Sensor for Monitoring Meibomian Gland Dysfunction
Autorzy:
Murawski, K.
Różycki, R.
Murawski, P.
Matyja, A.
Rękas, M.
Powiązania:
https://bibliotekanauki.pl/articles/1399390.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.30.Sy
07.07.Df
42.30.Va
Opis:
Meibomian gland dysfunction is one of the most common eye disorders observed in clinical practice. It applies to almost 50% of the population, especially people using contact lenses. It is believed that meibomian gland dysfunction is the most common cause of abnormal stability and integrity of the tear film. Despite this, there is no commercially available equipment for the diagnosis. The article proposes the construction of an optical sensor and a computer system for the rapid, non-invasive diagnosis of meibomian gland dysfunction. The designed hardware and software as well as preliminary results of clinical research are also described.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 517-520
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New Vision Sensor to Measure and Monitor Gas Pressure
Autorzy:
Murawski, K.
Powiązania:
https://bibliotekanauki.pl/articles/1402303.pdf
Data publikacji:
2015-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
06.30.Bp
07.05.Pj
07.07.Df
Opis:
The paper presents the construction and the use of a video sensor developed to measure air pressure. A characteristic feature of the device is pressure measurement based on digital image processing and self-diagnostics performed on the basis of an image. The paper presents the results of sensor calibration and measurements taken during the tests. It has been shown that the developed video-manometer model that is equipped with a flat diaphragm allows measuring the air pressure in the range of 0-100 mbar with an error less than 2%.
Źródło:
Acta Physica Polonica A; 2015, 128, 1; 6-9
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of Membrane Displacement Using a Motionless Camera
Autorzy:
Murawski, K.
Powiązania:
https://bibliotekanauki.pl/articles/1402304.pdf
Data publikacji:
2015-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
06.30.Bp
07.05.Pj
07.07.Df
Opis:
The paper presents a technique for measuring membrane displacements with one motionless camera. The method relies on measuring the distance to an object based on one image obtained from a motionless camera with a fixed-focus lens. It is proven that the used technique allows monitoring the frequency and amplitude of vibration. The tests were performed for the oscillation frequency in the range from 0.5 Hz to 6 Hz and deviations from the neutral position in the range of ± 3 mm.
Źródło:
Acta Physica Polonica A; 2015, 128, 1; 10-14
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multifunctional, Optical Sensor for Analysis of Dynamic Pupillary Light Reflex
Autorzy:
Różanowski, K.
Lewandowski, J.
Murawski, K.
Powiązania:
https://bibliotekanauki.pl/articles/1398782.pdf
Data publikacji:
2015-03
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.66.Ct
42.30.Va
07.05.Pj
07.07.Df
Opis:
The aim of the publication is to describe the multifunctional optical sensor for analysis of dynamic pupillary light reflex developed by the authors which could be used as an objective indicator of human fatigue. The authors utilized knowledge gained from past experimental studies to develop a sensor, which along with custom software for detection of parameters of dynamic pupillary reflex provides a quick analysis of the human psychophysiological condition. Furthermore, the obtained parameters may also be utilized for medical purposes. The authors present the results of pilot studies prior to the development process of the sensory solution. The obtained result show that the type of light stimulation of the retina has a significant impact on the dynamic parameters of the pupillary reflex. The results played also an important role in shaping the structural assumptions of the sensor, so that it can serve as an indicator of the human fatigue level. The article includes results of experimental research conducted during the testing process of the sensor using various parameters of frequency light excitations, luminance and chrominance.
Źródło:
Acta Physica Polonica A; 2015, 127, 3; 723-729
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies