Study of Physicochemical and Bacteriological Quality of Treated Wastewater by the New Aourir Plant (Southwestern of Morocco) Using Activated Sludge Technology in a Semi-Arid Region
Autorzy:
Hajji, Sara
Ait Alla, Aicha
Noureddine, Slimani
Haddad, Mohamed Ben
Moukrim, Abdellatif
Powiązania:
https://bibliotekanauki.pl/articles/1838277.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater
Morocco
physicochemical parameter
activated sludge
Aourir
bacteriological parameter
treatment plant
Opis:
In order to use the purified wastewater for the irrigation of a golf course in the Taghazout area (Southwestern of Morocco), this study was conducted to evaluate the physicochemical and bacteriological quality of the treated wastewater in the new Aourir plant (Activated Sludge technology). In order to achieve these objectives, three types of water were analyzed: raw water (RW), biologically treated water (BTW) and water treated by ultraviolet radiation (UV-TW). The physicochemical parameters analyzed were Temperature, pH, Electrical Conductivity (EC), Dissolved Oxygen (DO), Chemical Oxygen Demand (COD), five-day Biological Oxygen Demand (BOD5), Total Suspended Solids (SS), Nitrate (NO3), and Orthophosphates (PO4). Otherwise, the analyzed biological parameters are Total Coliforms (TC), Fecal Coliforms (FC), Escherichia coli (E. coli), and Fecal Streptococci (FS). The physicochemical parameters showed that temperature is always lower than 30°C, the pH is close to neutrality and a strong fluctuation of the high electrical conductivity (2700 μS/cm) occurs in UV-TW. At all stages of wastewater treatment, COD, BOD5, SS, NO3 and PO4 were below the limit values recommended by Moroccan standards. The bacteriological results showed a high level of bacterial contamination in RW and BTW, but in UV-TW the loads did not exceed 3 log10. The average loads of TC, FC, E. coli and FC in UV-TW were 2.13, 1.67, 1.77, and 2 (log10 CFU/100ml) respectively. Activated sludge treatment combined with UV has demonstrated sufficient quality to reuse treated water in irrigation; however, the UV treatment requires control to avoid any effect on the microbiological and physicochemical quality of green spaces and groundwater.
Źródło:
Journal of Ecological Engineering; 2021, 22, 6; 83-98
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of Physicochemical and Bacteriological Quality of Treated Wastewater by the New Aourir Plant (Southwestern of Morocco) Using Activated Sludge Technology in a Semi-Arid Region
Autorzy:
Hajji, Sara
Ait Alla, Aicha
Noureddine, Slimani
Haddad, Mohamed Ben
Moukrim, Abdellatif
Powiązania:
https://bibliotekanauki.pl/articles/1838386.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater
Morocco
physicochemical parameter
activated sludge
Aourir
bacteriological parameter
treatment plant
Opis:
In order to use the purified wastewater for the irrigation of a golf course in the Taghazout area (Southwestern of Morocco), this study was conducted to evaluate the physicochemical and bacteriological quality of the treated wastewater in the new Aourir plant (Activated Sludge technology). In order to achieve these objectives, three types of water were analyzed: raw water (RW), biologically treated water (BTW) and water treated by ultraviolet radiation (UV-TW). The physicochemical parameters analyzed were Temperature, pH, Electrical Conductivity (EC), Dissolved Oxygen (DO), Chemical Oxygen Demand (COD), five-day Biological Oxygen Demand (BOD5), Total Suspended Solids (SS), Nitrate (NO3), and Orthophosphates (PO4). Otherwise, the analyzed biological parameters are Total Coliforms (TC), Fecal Coliforms (FC), Escherichia coli (E. coli), and Fecal Streptococci (FS). The physicochemical parameters showed that temperature is always lower than 30°C, the pH is close to neutrality and a strong fluctuation of the high electrical conductivity (2700 μS/cm) occurs in UV-TW. At all stages of wastewater treatment, COD, BOD5, SS, NO3 and PO4 were below the limit values recommended by Moroccan standards. The bacteriological results showed a high level of bacterial contamination in RW and BTW, but in UV-TW the loads did not exceed 3 log10. The average loads of TC, FC, E. coli and FC in UV-TW were 2.13, 1.67, 1.77, and 2 (log10 CFU/100ml) respectively. Activated sludge treatment combined with UV has demonstrated sufficient quality to reuse treated water in irrigation; however, the UV treatment requires control to avoid any effect on the microbiological and physicochemical quality of green spaces and groundwater.
Źródło:
Journal of Ecological Engineering; 2021, 22, 6; 83-98
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of Physicochemical and Microbiological Quality of Taghazout Seawater (Southwest of Morocco): Impact of the New Tourist Resort "Taghazout Bay"
Autorzy:
Lamine, Imane
Alla, Aicha Ait
Bourouache, Mohamed
Moukrim, Abdellatif
Powiązania:
https://bibliotekanauki.pl/articles/124689.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
seawater
faecal coliforms
fecal streptococci
physicochemical quality
Taghazout Bay
Agadir
Morocco
Opis:
The marine environment plays a major socio-economic role in the Agadir region (south-west Morocco). This area, which hosts important fishery resources, is currently not spared from the pollutants produced in the course of agricultural, domestic, industrial and tourist development. The aim of this study is to assess the impact of the Taghazout bay tourist resort on the bacteriological and physicochemical quality of the coastal waters of Taghazout. The seawater samples were collected between March 2016 and March 2018 at three sampling sites (S1, S2 and S3) in order to monitor the concentrations of fecal coliforms (FC), fecal streptococci (FS) and total germs (TG). The results of physicochemical parameters show seasonal fluctuations influenced by climatic factors. The spatio-temporal monitoring of the bacteriological parameters shows that the average total germ count is 127.05 CFU/100 ml, 39.61 CFU/100 ml for fecal coliforms and 15.21 CFU/100 ml for fecal streptococci. The values of FC80, FC95 and FS90 do not exceed the guide values of the Moroccan standards. This classifies the Taghazout beach in category A (good quality of bathing water). The monitoring analysis recorded by the Pearson correlation test between the environmental parameters and the level of fecal bacteria showed that there was a significant positive correlation between the FC concentrations and rainfall; the FS concentrations showed significant positive correlations with all the environmental parameters while the TG concentrations indicate no correlation with them. The fecal contamination parameters should be routinely monitored for improving the environmental conditions of coastal cities. This must be the case for the Taghazout coastline where a regular monitoring program must be established to evaluate the impact of the new tourist resort “Taghazout bay” on the environmental quality of this ecosystem.
Źródło:
Journal of Ecological Engineering; 2019, 20, 7; 79-89
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies