Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Chochoł, K." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Gradient composite materials for artificial intervertebral discs
Autorzy:
Migacz, K.
Chłopek, J.
Morawska-Chochół, A.
Powiązania:
https://bibliotekanauki.pl/articles/306718.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
kompozyty
materiał gradientowy
krążek międzykręgowy
composite
gradient material
intervertebral disc replacement
Opis:
Composites with the gradient of the Young’s modulus constitute a new group of biomimetic materials which affect the proper distribution of stresses between the implant and the bone. The aim of this article was to examine the mechanical properties of gradient materials based on carbon fibre-polysulfone composite, and to compare them to the properties of a natural intervertebral disc. Gradient properties were provided by different orientation or volume fraction of carbon fibres in particular layers of composites. The results obtained during in vitro tests displayed a good durability of the gradient materials put under long-termstatic load. However, the configuration based on a change in the volume fraction of the fibres seems more advantageous than the one based on a change of the fibres’ orientation. Studied materials were designed to replace the intervertebral disc. The effect of the Young’s modulus of the material layers on the stress distribution between the tissue and the implant was analyzed and the biomimetic character of the gradient composites was stated. Unlike gradient materials, the pure polysulfone and the non-gradient composite resulted in the stress concentration in the region of nucleus pulposus, what is highly disadvantageous and does not occur in the stress distribution of natural intervertebral discs.
Źródło:
Acta of Bioengineering and Biomechanics; 2014, 16, 3; 3-12
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka mechaniczna wielofunkcyjnej resorbowalnej płytki kompozytowej do zespoleń kostnych
Mechanical characterization of multifunctional resorbable composite plate for osteosynthesis
Autorzy:
Gryń, K.
Szaraniec, B.
Morawska-Chochół, A.
Chłopek, J.
Powiązania:
https://bibliotekanauki.pl/articles/284036.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
osteosynteza
zespolenie kostne
płytki zespalające
płytki kompozytowe
płytki wielofunkcyjne
polimer resorbowalny
polilaktyd
hydroksyapatyt
fosforan wapnia
własności mechaniczne
parametry wytrzymałościowe
osteosynthesis
bone plate
composite plates
multifunctional plates
resorbable plates
poly-lactide
hydroxyapatite
tricalcium phosphate
mechanical characterisation
durability
Opis:
W artykule przedstawiono badania mechaniczne prototypowego wszczepu do zespoleń kostnych w postaci resorbowalnej wielofunkcyjnej czterootworowej płytki w kształcie litery I. Testy dotyczyły gotowych implantów w symulowanych warunkach pracy, a nie normatywnych próbek (wiosło, belka) dlatego przygotowano odpowiedni modelowy schemat badawczy implantu. Składał się on z dwóch bloczków imitujących odłamy kostne, połączonych za pomocą badanej płytki, który był poddawany testom mechanicznym w izolowanych stanach naprężeniowo-odkształceniowych (jednoosiowe rozciąganie, trójpunktowe i jednostronne zginanie). Badano płytki wykonane z dwóch odmian polimeru resorbowalnego (poli-L-laktydu) oraz dwa rodzaje kompozytu, w których osnowę stanowiła jedna z odmian polimeru, a fazą modyfikującą była mieszanina mikrometrycznego proszku ortofosforanu trójwapnia i nanometrycznego hydroksyapatytu. Badano także wpływ geometrii płytek na charakterystyki mechaniczne. Na podstawie przeprowadzonych badań stwierdzono wyraźny wpływ dodatków ceramicznych na zmianę parametrów wytrzymałościowych płytek wykonanych z różnych materiałów. W przypadku polilaktydu z dopuszczeniem medycznym zaobserwowano spadek wytrzymałości przy jednoczesnym podniesieniu modułu Younga E. Ponadto geometria implantu, czyli w badanym przypadku lokalizacja żeberka wzmacniającego, wpływała na uzyskane wyniki. Lepszymi parametrami cechowały się płytki z żeberkiem wzmacniającym na górnej stronie płytki. Ponadto podczas testów zginania stwierdzono, że przy tego rodzaju geometrii płytki pęknięcie lokalizuje się poza przekrojem krytycznym, a więc taka konstrukcja jest bardziej bezpieczna. Z grupy przebadanych prototypów, jako najlepsze, wybrano płytki kompozytowe PL38/TCP/HAp, wykonane z poli-L-laktydu medycznego, modyfikowanego mieszaniną proszków ceramicznych z żeberkiem wzmacniającym na powierzchni górnej. Mogą one znaleźć zastosowanie w osteosyntezie, w miejscach które nie są narażone na zbyt duże obciążenia mechaniczne. Do tej grupy zaliczyć można kości w obrębie twarzoczaszki oraz kości krótkie ręki. Zaleca się przy tym zastosowanie usztywniających opatrunków zewnętrznych.
The article presents the mechanical properties of prototype multifunctional four-hole, I-shaped plate made of resorbable composite and used for osteosynthesis. Multiple tests were conducted on ready-to-use implants and run in simulated real-working conditions. A special customized test stand was constructed for the sake of this research. The model of the osteosynthesis consisted of two rectangular pieces of plexiglas joined together by means of the tested plate. Durability of the physical model was mechanically assessed in static uniaxial tensile, three-point bending, one-side bending tests. Two types of resorbable polymers (poly-L-lactide) and two types of composites based on these polymers were considered. The composites were modified with a combination of two types of bioceramic: micrometric tricalcium phosphate and nanometric hydroxyapatite. The relation between the geometry of the plate and its mechanical characteristics was also investigated for all the tested materials. The test results proved that incorporation of bioceramic modifiers into the polylactide matrix influences the mechanical behaviour of the tested bone plates. The composite based on FDA approved polylactide (PL38) revealed the strength decrease while the Young modulus increased at the same time. The mechanical parameters were also dependent on the geometry of the plate (localization of a stiffening rib). Better results were obtained for the plates with a stiffening rib located on the upper side of the plate. What is more, the three-point-bending test revealed that in such a case the crack line moved away from the critical cross section, making such a plate more reliable. The best parameters were achieved for the three- -component plates (PL38/TCP/Hap) with a stiffening rib on the upper side. They can be potentially applied for osteosynthesis of the bones submitted with rather low loads, e.g. craniofacial bones, metacarpal bones or phalanges. An external stiff stabilisation (a plaster cast) is recommended as an additional support and prevention.
Źródło:
Engineering of Biomaterials; 2015, 18, 133; 22-33
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of the degradation process on the PLA/TCP locking bolt thread strength as a part of intramedullary locking nail system
Autorzy:
Gryń, K.
Szaraniec, B.
Ziąbka, M.
Morawska-Chochół, A.
Chłopek, J.
Powiązania:
https://bibliotekanauki.pl/articles/285252.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
degradation
intramedullary nailing
bioresorbable materials
Opis:
Intramedullary nailing has received increased attention for the treatment of distal femoral fractures. There are many types of nailing systems commonly used. Among them there is locked intramedullary nailing, which combines closed nailing with a special locking piece (bolt), which expands distal part of a nail and anchoring it when a central screw is tightened. Compared to other interlocking nail systems it is very effective and not so invasive way of fractured long bone treatment. However, it is not perfect and has one major disadvantage related to material (metal) and necessity of removing all parts of the system after the bone is recovered. The biggest issue is connected with the locking piece removal. That is why there was a need to find a material for this piece which is biodegradable and strong enough to maintain its mechanical function at the same time. Poly-L-lactide (PLA) is nowadays one of the most used bioabsorbable materials. Unfortunately, this polymer may not meet some application requirements due to inadequate mechanical properties and its degradation characteristics. One of the easiest ways to overcome these obstacles is to introduce an inorganic phase into the polymer matrix to create a composite. In this article a production method of a biodegradable composite (PLA/TCP, 90/10) locking piece of an interlocking intramedullary nail called "OLIVE" and the influence of degradation process in simulated physiological conditions (H2O, PBS) on its mechanical properties is shown. Main stress was placed on the inner thread strength to discover how it changes with time. A special device for mechanical testing machine imitating working conditions was fabricated. 148 Based on SEM observations, pH and electric conductivity monitoring after 14 days no degradation was found. However, mechanical testing shown, that after incubation for such period of time the material was more ductile. Instead of cracking, what was observed for not incubated samples, they changed their shape during the testing process. Nevertheless, it didn't radically influence on the inner thread strength and didn't change mechanical function of the olive. No inner thread destruction was discovered contrary to a metallic screws which in all cases were broken. Preliminary results indicate that proposed composite and an implant made of this material might be used as a locking piece in a locked intramedullary nailing system.
Źródło:
Engineering of Biomaterials; 2012, 15, no. 116-117 spec. iss.; 148
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biodegradable binary blends of polylactide and polycaprolactone
Autorzy:
Domalik-Pyzik, P.
Morawska-Chochół, A.
Misztal, M.
Pazdan, K.
Chłopek, J.
Powiązania:
https://bibliotekanauki.pl/articles/286062.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
polyesters
biodegradation
tissue engineering
Źródło:
Engineering of Biomaterials; 2016, 19, 138; 14
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies