Tytuł:
Digital image correlation of coated and uncoated Religa Heart_Ext ventricular assist device
Autorzy:
Kopernik, M.
Gawlikowski, M.
Milenin, A.
Altyntsev, I.
Kustosz, R.
Kąc, S.
Powiązania:
https://bibliotekanauki.pl/articles/307138.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
komorowe wspomaganie pracy serca
VAD
korelacja obrazów
DIC
azotek tytanu
Tin
złoto
ventricular assist device
digital image correlation
titanium nitride
TiN
gold
Opis:
The digital image correlation is used to estimate influence of deposited heamocompatible coatings (gold and titanium nitride) on mechanical response of ventricular assist device Religa Heart_Ext made of Bionate II (thermoplastic polycarbonate urethane) under working conditions by comparison of the coated Religa Heart_Ext with uncoated Religa Heart_Ext. The DIC is applied for experimental investigation of the strains and displacements distribution on external surface of the blood chamber of ventricular assist device during loading. The experiment was conducted in a hydraulic system with water at operating temperatures of 25 and 37 °C, as well as under static pressures: 80, 120, 180, 220 and 280 mmHg, and static underpressures: –25, –45, –75 mmHg. The subsequent images were taken after stabilization of pressure on a set level. The applied research method shows that the nano-coating of 30 nm in thickness significantly affects deformation of the blood chamber of Religa Heart_Ext in macro scale. The proposed composition of coatings increases strain on external surface of the ventricular assist device.
Źródło:
Acta of Bioengineering and Biomechanics; 2015, 17, 4; 49-58
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical And Experimental Analysis Of Fracture Of Athrombogenic Coatings Deposited On Ventricular Assist Device In Micro-Shear Test
Numeryczna i doświadczalna analiza pękania atrombogennych powłok nanoszonych na komory wspomagania pracy serca w próbie mikrościnania
Autorzy:
Kopernik, M.
Milenin, A.
Kąc, S.
Powiązania:
https://bibliotekanauki.pl/articles/354256.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
micro-shear test
finite element method (FEM)
fracture
ventricular assist device (VAD)
titanium nitride (TiN)
gold (Au)
próba mikrościnania
metoda elementów skończonych (MES)
pękanie
komora wspomagania pracy serca
azotek tytanu (TiN)
złoto (Au)
Opis:
The Polish left ventricular assist device (LVAD – RELIGA_EXT) will be made of thermoplastic polycarbonate-urethane (Bionate II) with deposited athrombogenic nano-coatings: gold (Au) and titanium nitride (TiN). Referring to the physical model, the two-scale model of LVAD developed in the previous works in the authors’ finite element code is composed of a macro-model of blood chamber and a micro-model of wall: TiN, Au and Bionate II. The numerical analysis of stress and strain states confirmed the possibility of fracture based on localization of zones of the biggest values of triaxiality factor. The introduction of Au interlayer between TiN and polymer improved the toughness of the connection, and increased the compressive residual stress in the coating what resulted in reduction of stress and strain close to the boundary between substrate and coating. However, the proper design of multilayer wall of the medical device requires the introduction of the real stress and strain states in the deposited coatings. The characteristics of TiN nano-coating such as residual stress, material model and fracture model were determined in the previously completed studies such as experimental and numercial nanoindentation tests, profilometry studies and in situ SEM’s micro-tension tests. The experimental in situ SEM’s micro-shear test was performed in the present paper and the corresponding numerical model of the test was also developed, and then, interpreted. The critical strains taken from experiment and considered as the effective strains in the model of test are the values which are the function of triaxiality factors for the tested samples. The developed in the authors’ FE code model of multilayer wall of VAD enriched with critical strain determined in the present paper enables prediction of fracture.
Polska lewa komora wspomagania pracy serca (LVAD – RELIGA_EXT) zostanie wykonana z termoplastycznego poliwęglano-uretanu (Bionate II) z naniesionymi atrombogennymi powłokami: złota (Au) i azotku tytanu (TiN). W odniesieniu do modelu fizycznego, dwuskalowy model komory LVAD opracowany we wcześniejszych pracach w autorskim kodzie elementów skończonch jest złożony z modelu makro czaszy krwistej i z mikro-modelu ściany: TiN, Au i Bionate II. Analiza numeryczna stanów naprężenia i odkształcenia potwierdziła prawdopodobieństwo pękania poprzez zlokalizowanie stref o największej wartości współczynnika naprężenia trójosiowego. Wprowadzenie międzywarstwy złota pomiędzy TiN i polimer poprawiło wytrzymałość tego połączenia i powiększyło ściskające naprężenie własne w powłoce, co doprowadziło do redukcji naprężenia i odkształcenia blisko granicy pomiędzy podłożem i powłoką. Jednakże, właściwy projekt wielowarstwowej ściany urządzenia medycznego wymaga wprowadzenia rzeczywistych stanów naprężeń i odkształceń w naniesionych powłokach. Charakterystyki powłok TiN takie jak naprężenie własne, model materiału i model pękania zostały określone we wcześniej wykonanych badaniach takich jak doświadczalne i numeryczne testy nanoindentacji, badania profilometryczne, i testy mikrorozciągania prowadzone pod elektronowym mikroskopem skaningowym. W niniejszej pracy przeprowadzono doświadczalny test mikrościnania pod skaningowym mikroskopem elektronowym, opracowano model numeryczny tego testu, a następnie go zinterpretowano. Odkształcenia krytyczne otrzymane z doświadczenia i określone w modelu testu jako intensywność odkształcenia są wartościami będącymi funkcją współczynników naprężeń trójosiowych dla badanych próbek. Opracowany w kodzie własnym model elementów skończonych wielowarstwowej ściany komory VAD wzbogacony o określone w niniejszej pracy odkształcenia krytyczne umożliwia przewidywanie pękania.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 2A; 795-800
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies