Telemedical system for home fetal monitoring with online analysis of bioelectricalabdominal signals
Autorzy:
Wróbel, J.
Jeżewski, J.
Matonia, A.
Kupka, T.
Gacek, A.
Roj, D.
Powiązania:
https://bibliotekanauki.pl/articles/333489.pdf
Data publikacji:
2008
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitoring domowy
telemedycyna
ciąża zagrożona
nadzór płodu
home monitoring
telemedicine
high-risk pregnancy
fetal surveillance
Opis:
This paper presents some aspects of the on-line remote fetal monitoring system based on the GPRS data transmission service and WAN network. The remote signal recording instrumentation consists of bioelectrical signal recorder and tablet PC computer. The central surveillance system located in hospital has a capability of simultaneous monitoring of up to 24 patients, both remotely and within hospital. The system enables analysis, dynamic presentation and archiving of signals and medical data. The clinical interpretation is immediately available in hospital as well as at patient's home or attending doctor office.
Źródło:
Journal of Medical Informatics & Technologies; 2008, 12; 91-95
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Neonatal surveillance system based on data stream technology
Autorzy:
Widera, M.
Matonia, A.
Wróbel, J.
Jeżewski, J.
Horoba, K.
Kupka, T.
Powiązania:
https://bibliotekanauki.pl/articles/333868.pdf
Data publikacji:
2005
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie
pulsoksymetr
strumienie
monitoring
pulse oxymetry
streams
Opis:
Pulse oximetry is a non-invasive measurement method of an arterial blood oxygen saturation. Pulse oximeter is one of the main bedside monitors used in neonatal units. The dispersed location of medical devices in such unit renders impossible to make a fast and valid decision in the case of simultaneous alarming situation. This paper present hardware and software structure of centralised neonatal monitoring system. Presented system can work as a single central station for monitoring of up to twenty four patients. Application of central monitoring system decreases the risk of undetected patients live and health threats. Thanks to this system the medical stuff is less burdened by routine procedures; therefore the medical unit is perceived as child- and mother-friendly.
Źródło:
Journal of Medical Informatics & Technologies; 2005, 9; 93-98
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of window size of autocorrelation function on fetal heart rate variability measurement using the Doppler ultrasound signal
Autorzy:
Roj, D.
Fuchs, T.
Przybyła, T.
Jeżewski, M.
Matonia, A.
Gacek, A.
Powiązania:
https://bibliotekanauki.pl/articles/333477.pdf
Data publikacji:
2008
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitoring płodu
tętno płodu
USG Dopplera
funkcja autokorelacji
fetal monitoring
fetal heart rate
Doppler ultrasound
autocorrelation function
Opis:
Commonly used noninvasive fetal monitoring is based on fetal heart rate (FHR) variability analysis of the Doppler ultrasound signal coming from the mechanical activity of the fetal heart. Estimation of periodicity of acquired signals using the autocorrelation technique is very important. The determination of cardiac intervals using the Doppler signal is more difficult than in electrocardiography, where the R-waves are evident. We investigated the influence of the autocorrelation window size on the FHR variability analysis. The indices describing the FHR variability calculated for signals obtained using two different autocorrelation techniques with various window lengths were compared with the reference ones obtained from fetal electrocardiogram. The optimal window was a compromise between artifacts resistance and the averaging level of instantaneous variability.
Źródło:
Journal of Medical Informatics & Technologies; 2008, 12; 111-116
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simultaneous recording and analysis of direct and indirect fetal electrocardiography
Autorzy:
Matonia, A.
Jeżewski, J.
Kupka, T.
Horoba, K.
Bernys, M.
Powiązania:
https://bibliotekanauki.pl/articles/333338.pdf
Data publikacji:
2004
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
EKG płodu
monitorowanie płodu
fetal electrocardiography
fetal monitoring
Opis:
Recording and analysis of fetal heart rate variability is still the most common method for detection of early symptoms of fetal hypoxia. However, fetal heart rate obtained via ultrasound describes only mechanical activity of fetus heart. Limitations of this technique have stimulated the development of fetal electrocardiography. It ensures more precise determination of fetal heart rate and, which is more important, enables assessment of the morphology of the fetal QRS complexes. In this paper two techniques of obtaining the fetal electrocardiogram are described and their comparative study is presented.
Źródło:
Journal of Medical Informatics & Technologies; 2004, 8; MM111-118
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Separation of abdominal fetal electrocardiograms in twin pregnancy
Autorzy:
Kotas, M.
Jeżewski, J.
Matonia, A.
Kupka, T.
Powiązania:
https://bibliotekanauki.pl/articles/333491.pdf
Data publikacji:
2008
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
analiza składowych niezależnych
projekcyjne filtrowanie
EKG płodu
monitoring płodu
ciąża bliźniacza
independent component analysis
projective filtering
fetal ECG
fetal monitoring
twin pregnancy
Opis:
A combined application of independent component analysis and projective filtering of the time-aligned ECG beats is proposed to solve the problem of fetal ECG extraction from multi-channel maternal abdominal electric signals. The developed method is employed to process the four-channel abdominal signals recorded during twin pregnancy. The signals are complicated mixtures of the maternal ECG, the ECGs of the fetal twins and noise of other origin. The independent component analysis cannot separate the respective signals, but the proposed combination of the methods allows to suppress the maternal ECG and when the level of noise is low it leads to an effective separation of the twins' signals.
Źródło:
Journal of Medical Informatics & Technologies; 2008, 12; 83-89
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel approach to comparison of the fetal heart rate baseline estimation algorithms
Autorzy:
Jezewski, J.
Horoba, K.
Roj, D.
Wrobel, J.
Kupka, T.
Matonia, A.
Powiązania:
https://bibliotekanauki.pl/articles/332862.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
fetal monitoring
baseline estimation
acceleration
deceleration
monitorowanie płodu
estymacja
przyspieszanie
zwalnianie
Opis:
A number of algorithms for estimating the so called fetal heart rate baseline was proposed so far. However, there is no reference pattern enabling their objective evaluation, and thus no methodology of comparing the competing algorithms still exists. In this paper we propose a method for evaluation of automatically determined baseline in reference to a group of experts, basing on ten separate groups of signals comprising typical patterns observed in the fetal heart rate. For the purpose of quantitative assessment of the estimated baseline a new synthetic inconsistency coefficient is presented. The proposed methodology was applied to evaluate ten well-known algorithms. We believe that the method will be a valuable tool for assessment of the existing algorithms, as well as for developing new ones.
Źródło:
Journal of Medical Informatics & Technologies; 2015, 24; 231-238
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indexing biomedical streams in data management system
Autorzy:
Widera, M.
Wróbel, J.
Matonia, A.
Jeżewski, M.
Horoba, K.
Kupka, T.
Powiązania:
https://bibliotekanauki.pl/articles/333832.pdf
Data publikacji:
2005
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
scentralizowane monitorowanie
przetwarzanie strumienia danych
indeksowanie
centralized monitoring
data stream processing
indexing
Opis:
We are developing Data Stream Management System that can be applied in medical monitoring system. One of the problems is how to support efficient data access methods. This paper considers indexing issues in data management system. The indexing is a commonly used method of data access acceleration. Classical and new streaming methods of indexing have been presented. The method was developed in data stream management system and first applied in a centralized neonatal monitoring system.
Źródło:
Journal of Medical Informatics & Technologies; 2005, 9; 107-112
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of instantaneous fetal heart rate extracted from abdominal and direct fetal electrocardiograms
Autorzy:
Matonia, A.
Kupka, T.
Jezewski, J.
Momot, A.
Jeżewski, M.
Bernys, M.
Powiązania:
https://bibliotekanauki.pl/articles/333262.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
elektrokardiografia płodu
tętno płodu
fetal monitoring
fetal electrocardiography
fetal heart rate
Opis:
This work is an attempt to assess the reliability of indirect abdominal electrocardiography as an alternative technique of fetal monitoring. As a reference signal we used the simultaneously acquired direct fetal electrocardiogram. Each recording consisted of four signals acquired from maternal abdomen and the reference signal acquired directly from fetal head. The first stage of our study concerned the signal loss episodes. In order to reduce the influence of incorrectly detected R-waves, some certain validation rules were applied. In the second stage, the corresponding intervals determined on basis of both acquisition methods were matched and the accuracy of fetal heart rate measurement was evaluated. Although the accuracy of abdominal electrocardiography turned out to be slightly lower than reported for ultrasound method, it still has some unique features deciding of its prevalence in a certain circumstances.
Źródło:
Journal of Medical Informatics & Technologies; 2012, 19; 101-107
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computerized fetal monitoring based on bioelectric signals from maternal abdomen
Autorzy:
Matonia, A.
Jeżewski, J.
Gacek, A.
Kupka, T.
Horoba, K.
Wróbel, J.
Powiązania:
https://bibliotekanauki.pl/articles/333805.pdf
Data publikacji:
2002
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
elektrokardiografia
tętno płodu
fetal monitoring
fetal abdominal
electrocardiography
fetal heart rate
Opis:
The paper presents an instrumentation set for effective diagnostics of early symptoms of fetal distress in high-risk pregnancy based on bioelectric signals recording. The representative database of records has been established that enabled the complex analysis of signals recorded on a surface of maternal abdomen. As an outcome, the effective algorithms have been developed for processing both the fetal electrocardiogram and the signal of electrical activity of a uterine muscle. This allowed the development of unique diagnostic system based on external biosignal measurement module connected to the standard personal computer. In this system, like in a classical fetal monitor, the fetal heart rate (FHR) signal together with contraction activity signal of uterine muscle and fetal movement become an essential source of information on fetal condition. In addition, there is a possibility for spectral analysis of FHR signal as well as a morphology assessment of fetal ECG signal.
Źródło:
Journal of Medical Informatics & Technologies; 2002, 4; MT37-47
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Coincidence of maternal and fetal QRS complexes in view of fetal heart rate determination
Autorzy:
Kupka, T.
Jeżewski, J.
Matonia, A.
Wróbel, J.
Horoba, K.
Powiązania:
https://bibliotekanauki.pl/articles/333792.pdf
Data publikacji:
2002
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
brzuszne EKG płodu
monitorowanie płodu
tętno płodu
abdominal fetal electrocardiogram
fetal monitoring
fetal heart rate
Opis:
Indirect fetal electrocardiography is a developing diagnostic method in perinatal medicine. Signals of electrical activity being recorded from maternal abdomen surface contain more information than in till now used method of mechanical heart activity measurement based on ultrasound signals. The main problem relies on separation of basic useful component from a signal containing also dominant maternal electrocardiogram and muscles activity artifacts. The algorithms of maternal electrocardiogram suppression via subtraction are commonly used. Although regarding their complexity, these algorithms have limited applicability in systems for long-term monitoring of fetal heart activity. Other solution relies on simple blanking of maternal QRS complexes. However, in case of coincidence of fetal and maternal QRS complexes, this leads to partial loss of information about fetal heart rate variability. For evaluation of how often such coincidence of both complexes takes place, the algorithm has been developed which is described in this paper.
Źródło:
Journal of Medical Informatics & Technologies; 2002, 4; MT49-55
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Smart selection of signal analysis algorithms for telecare of high-risk pregnancy
Autorzy:
Wróbel, J.
Matonia, A.
Horoba, K.
Jeżewski, J.
Czabański, R.
Pawlak, A.
Porwik, P.
Powiązania:
https://bibliotekanauki.pl/articles/333593.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
fetal monitoring
abdominal fetal electrocardiogram
smart signal processing
telemedicine
monitorowanie płodu
brzuszne EKG płodu
inteligentne przetwarzanie sygnałów
telemedycyna
Opis:
Telemedical system for fetal home monitoring with smart selection of signal analysis algorithms is presented in this paper. Fetal monitoring signals are provided by a mobile instrumentation consisting of bioelectrical signal recorder and tablet PC which retrieves and processes the data as well as provides wireless data transmission based on Internet. The fetal surveillance system enables analysis, dynamic presentation and archiving of acquired signals and medical data. Novelty of the proposed approach relies on smart fitting of the algorithms for analysis of the abdominal signals in mobile instrumentation, as well as on controlling of the fetal monitoring session from the surveillance center. These actions are performed automatically through continuous analyzing of the signal quality and the reliability of the quantitative parameters determined for the acquired signals. Using that approach the amount and content of data transmitted through remote channels to the surveillance center can be controlled to ensure the most reliable assessment of the fetal well-being.
Źródło:
Journal of Medical Informatics & Technologies; 2014, 23; 27-33
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Combined analysis of fetal electrocardiogram and systolic time intervals
Autorzy:
Matonia, A.
Jeżewski, J.
Kupka, T.
Horoba, K.
Wróbel, J.
Widera, M.
Powiązania:
https://bibliotekanauki.pl/articles/334019.pdf
Data publikacji:
2003
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
wybrany termin cyklu sercowego
EKG płodu
tętno płodu
fetal monitoring
cardiac cycle timing
fetal electrocardiography
fetal heart rate
Opis:
Cardiotocography as a simultaneous recording of fetal heart rate (FHR) and uterine contraction activity is a basic method of evaluation of fetal condition. Correct variability of the fetal heart rate is an indirect sign of adequate oxygenation of a fetus. Unfortunately, the reverse case is not always true, signs suggesting pathological changes can also appear in recording when the fetal is not at risk. The cardiotocography shall then be recognized as a more screening than diagnostic method. It will be interesting to develop a non-invasive method being complementary to routine cardiotocography. This method should allow the adequate prediction of a bad neonatal outcome when the test is abnormal. The paper shows the system that makes possible cardiotocograms analysis in parallel with the assessment of additional parameters determined from comparison of mechanical and electrical fetal heart activity signals. The studies are aimed at development of set of parameters that are high correlated with clinical outcome.
Źródło:
Journal of Medical Informatics & Technologies; 2003, 6; IT27-34
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Data stream processing in fetal monitoring system: II. Application to signal processing
Autorzy:
Jeżewski, J.
Widera, M.
Winiarczyk, R.
Matonia, A.
Kupka, T.
Gacek, A.
Powiązania:
https://bibliotekanauki.pl/articles/334015.pdf
Data publikacji:
2003
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
język zapytań
przetwarzanie strumienia danych
system zarządzania bazami danych
monitorowanie płodu
query language
data stream processing
database management system
fetal monitoring
Opis:
Fetal monitoring system belongs to signal processing system class. The main functions of the system are signal acquisition from bedside monitors, on-line trace analysis and dynamic presentation of incoming data. Collected data set is controlled by centralised application. Relational database management system cannot process samples of high frequency biomedical signals on-line. Therefore, we decide to build our own data management system dedicated to stream processing that support continuous query. This paper describes a method of building a query plan based on proposed algebra. The presented example of application enables implementation of algorithm determining long- and short-term indices for fetal heart rate variability assessment on the basis of declarative query language. Our solution enables to define query based on data streams that make the updated answers currently available.
Źródło:
Journal of Medical Informatics & Technologies; 2003, 6; IT35-42
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies