Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Naumczyk, J." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Treatment of highly polluted cosmetic wastewater
Autorzy:
Naumczyk, J.
Marcinowski, P.
Bogacki, J.
Powiązania:
https://bibliotekanauki.pl/articles/206908.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
coagulation
cosmetic wastewater
sedimentation
Fenton method
biological wastewater treatment plants
ścieki kosmetyczne
koagulacja
sedymentacja
biologiczne oczyszczanie ścieków
metoda Fentona
Opis:
Three samples of cosmetic wastewater from the production of soaps and shampoos were treated by the following processes: coagulation with sedimentation (C/S), coagulation with dissolved air flotation (C/DAF), and the Fenton process (FP). The COD values of raw wastewater samples were 13 160, 13 580 and 9410 mg O2/dm3. The anionic surfactants were 3000, 4500 and 4000 mg/dm3, for samples 1, 2, and 3, respectively. All three processes were effective in highly polluted cosmetic wastewater treatment. The most effective process was coagulation. In the case of sample 1, application of FeCl3 at pH 6.0 resulted in 88.2% of COD removal and the application of aluminum based coagulants allowed for 80.1–85.3% COD removal. In the case of samples 2 and 3, the usage of Al 1019 and Al 3010 coagulants brought about a 91.6% and 82.6% decrease in COD values, respectively. C/DAF was found to be less effective than C/S. The best results with C/DAF were obtained using Al 3010 coagulant with wastewater recirculation the COD removal efficiency amounted to 82.3, 87.3 and 78.8, respectively. The lowest COD removal efficiency was observed for FP and it was equal to 64.0 and 72.7% for samples 2 and 3, respectively.
Źródło:
Environment Protection Engineering; 2017, 43, 2; 25-40
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cosmetic wastewater treatment using coagulation and Fenton processes
Autorzy:
Bogacki, J.
Marcinowski, P.
Naumczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/115676.pdf
Data publikacji:
2015
Wydawca:
Fundacja na Rzecz Młodych Naukowców
Tematy:
cosmetic wastewater
wastewater treatment
coagulation
Fenton process
ścieki kosmetyczne
oczyszczanie ścieków
koagulacja
proces Fentona
Opis:
The cosmetic wastewater was treated by coagulation and Fenton process. COD of raw wastewater was 2888 mg/l. The effectiveness of these processes, defined as a decrease of COD was 66.4% for coagulation for a FeCl3 dose 900 mg/l and 87.7% (to 295mg/l COD) for Fenton process for H2O2/Fe2+ doses 3000/1000mg/l. The contribution of coagulation in Fenton process was defined as 71.3% of the total treatment effect. The calculated H2O2 efficiency is high and for optimal doses reached 149.3%. The optimal pH of Fenton process is 3.0. Even a small change in its value leads to a rapid decrease in the efficiency of oxidation and hence in the effects of the process. The kinetics of the Fenton process can be described as d[COD]/dt =-a tm [COD], where t stands for time, while the a and m are constants, depending on the initial concentration of the reagents. It has been proved that the cosmetic wastewater is susceptible to purification by means of coagulation and Fenton process.
Źródło:
Challenges of Modern Technology; 2015, 6, 4; 36-42
2082-2863
2353-4419
Pojawia się w:
Challenges of Modern Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczanie ścieków kosmetycznych metodami fizykochemicznymi i chemicznymi
Treatment of cosmetic wastewater using physicochemical and chemical methods
Autorzy:
Bogacki, J.
Naumczyk, J.
Marcinowski, P.
Kucharska, M.
Powiązania:
https://bibliotekanauki.pl/articles/1219309.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
oczyszczanie ścieków
ścieki kosmetyczne
PPCPs
wastewater treatment
cosmetic sewage
Opis:
W pracy dokonano przeglądu piśmiennictwa dotyczącego skuteczności fizykochemicznych i chemicznych metod oczyszczania ścieków kosmetycznych. Omawiane procesy mogą być głównym stopniem oczyszczania ścieków, bądź etapem poprzedzającym oczyszczanie biologiczne. Wyniki uzyskiwane przez poszczególnych autorów trudno ze sobą porównać ze względu na bardzo dużą różnorodność składu i stężeń zanieczyszczeń. O doborze metody oczyszczania powinny decydować skład ścieków i wymagania dotyczące stopnia oczyszczenia ścieków.
The paper is a review of literature on the effectiveness of physicochemical and chemical methods of cosmetic wastewater treatment. These methods may be the principle level of treatment, or be a stage prior to biological treatment. The result obtained by different authors is difficult to compare because of the very high variability of the composition and concentrations of pollutants in wastewater. The selection of treatment methods should be decided by the composition of wastewater and legal requirements that must be met before discharge of wastewater into the receiver.
Źródło:
Chemik; 2011, 65, 2; 94-97
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczanie ścieków z przemysłu kosmetycznego za pomocą procesu koagulacji
Cosmetic wastewater treatment by coagulation
Autorzy:
Naumczyk, J.
Marcinowski, P.
Wiliński, P.
Bogacki, J.
Powiązania:
https://bibliotekanauki.pl/articles/1818746.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczanie ścieków
proces koagulacji
polycyclic musk fragrances
sewage treatment plant
contrast media
uv filters
removal
pharmaceuticals
oxidation
ahtn
hhcb
wastewaters
Opis:
In this study the coagulation process of five cosmetics wastewater types has been investigated. All samples were collected from big cosmetic factory in Poland. Due to changeable production profile, also significant changeability of the wastewater composition and the concentration of pollutants were observed. COD values of raw wastewaters samples 1, 2, 3, 4 and 5 were as follows: 7293, 3241, 3241, 5132 and 1089 mg/l, respectively. Before coagulation easily settleable suspended solids were removed by 30 min primary sedimentation. After sedimentation COD values were decreased to 1134, 2512, 3241, 1858 and 1089 mg/l, respectively. Coagulation with Al2 (SO4)3 at pH 7.0 and FeCl3 at pH 6.0 and 9.0 allowed to achieve COD removal in the range of 33.0–63.5%. The effect of coagulation was better for the samples of lower contents of easily settleable suspended solids and higher content of fine suspended solids. The best effects of COD removal by coagulation achieved for investigated wastewaters were as follow: sample 1 – 39.2%, by Al2 (SO4) 3 and FeCl3 at pH 9.0; sample 2 – 54.8%, by FeCl3 at pH 6.0; sample 3 – 60.0%, by Al2 (SO4) 3; sample 4 – 33.3%, by Al2 (SO4) 3; sample 5 – 63.5%, by FeCl3 at pH 6.0. The differences in coagulants effectiveness were not significant. Flopam flocculant improved the effect of coagulation – shortened the clarification time from 60 min to 5 min, reduced the coagulant doses by about 50 mg/l and increased COD removal. In the coagulation assisted by Flopam flocculant, Al2 (SO4) 3 proved to be the best coagulant for sample 3 (62.5%), FeCl3 at pH 6.0 was the best for sample 2 (54.8%) and sample 5 (63.9% – the best result of all) and FeCl3 at pH 9.0 for sample 4 (50.0%). The best effect of coagulation was achieved for sample no 5, which had no easily settleable suspended solids. The total effect of COD removal, including primary sedimentation and coagulation ranged from 63.9 to 90.6%. GC-MS analysis allowed to identify 110 compounds. The predominant compounds identified by GC-MS were: cyclopentasiloxane, decamethylcyclopentasiloxane and synthetic musk – galaxolide (HHCB). HHCB concentration was decreased in the coagulation by 87.3–92.2%. The degree of other compounds removal varied in the range 0–99.4%.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 1; 873-891
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cosmetic wastewater treatment using dissolved air flotation
Oczyszczenie ścieków kosmetycznych z wykorzystaniem procesu flotacji ciśnieniowej
Autorzy:
Bogacki, J. P.
Marcinowski, P.
Naumczyk, J.
Wiliński, P.
Powiązania:
https://bibliotekanauki.pl/articles/205185.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wastewater treatment
GC-MS
gas chromatography
cosmetic wastewater
dissolved air flotation
PPCPs
pharmaceutical and personal care pollutants
oczyszczanie ścieków
chromatografia gazowa
ścieki kosmetyczne
flotacja ciśnieniowa
Opis:
Five cosmetics wastewater samples were treated by Dissolved Air Flotation (DAF) assisted by coagulation. Different aluminum based coagulants were used: (Al2(SO4)3, Al 1019, Al 3010, Al 3030, Al 3035, PAX 16 and PAX 19). The raw wastewater COD values were in the range 285–2124 mg/l. The efficiency of DAF depended on different coagulants and production profile of factory. COD removal was varied from 11.1 to 77.7%. The efficiency of coagulants was similar during treatment of particular sample. The best results were obtained with Al2(SO4)3 and for sample 5 – lotions and shampoos production. The wastewater from UV filter creams production (sample 4) was resistant to treatment by DAF regardless of used coagulant. HS-SPME-GC-MS analysis can be a confirmation of DAF effectiveness.
Pięć próbek ścieków kosmetycznych zostało poddanych oczyszczaniu z wykorzystaniem flotacji ciśnieniowej wspomaganej koagulacją. Stosowano różne koagulanty na bazie glinu: Al2(SO4)3, Al 1019, Al 3010, Al 3030, Al 3035, PAX 16 and PAX 19. Wartość ChZT ścieków surowych była w zakresie 285–2124 mg/l. Skuteczność procesu flotacji ciśnieniowej była zależna od zastosowanego koagulantu i profilu produkcji fabryki kosmetyków. Skuteczność usunięcia wartości ChZT była w przedziale 11,1–77,7%. Skuteczność wszystkich koagulantów podczas oczyszczania każdej z próbek ścieków była podobna. Najlepsze rezultaty uzyskano z wykorzystaniem koagulantu Al2(SO4)3 , dla próbki 5 – ścieki pochodzące z produkcji szamponów i logionów. Ścieki z produkcji kremów z filtrem UV (próbka 4) były oporne na oczyszczanie za pomocą procesu flotacji ciśnieniowej, niezależnie od zastosowanego koagulantu. Zastosowana analiza HS-SPME-GC-MS potwierdziła skuteczność oczyszczania z wykorzystaniem flotacji ciśnieniowej.
Źródło:
Archives of Environmental Protection; 2017, 43, 2; 65-73
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies