Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Sun, Y.-J." wg kryterium: Wszystkie pola


Wyświetlanie 1-7 z 7
Tytuł:
Investigation on Irreversible Expansion of 1,3,5-Triamino-2,4,6-trinitrobenzene Cylinder
Autorzy:
Sun, J.
Kang, B.
Zhang, H.
Liu, Y.
Xia, Y.
Yao, Y.
Liu, X.
Powiązania:
https://bibliotekanauki.pl/articles/357936.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
TATB
irreversible expansion
XRD
lattice parameters
Opis:
In this study, the irreversible expansion of TATB cylinder is investigated. No evident variation of the lattice parameters is observed on TATB crystal. The density of TATB powder decreases by only about 0.02% after it suffered from thermal cycling process at the range from -54 C to 74 C, while the density of TATB cylinder decreases by about 1.0%. It is suggested that the density variation of TATB powder has little contribution to the density decrease of TATB cylinder. Therefore, the increasing interstices between TATB powder originated from the thermal cycling should be responsible to the irreversible expansion of TATB cylinder.
Źródło:
Central European Journal of Energetic Materials; 2011, 8, 1; 69-79
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Visual Detection Method of Longitudinal Crack Based on Computer Image Processing During Slab Continuous Casting
Autorzy:
Liu, Y.
Wang, X.
Sun, Y.
Du, F.
Gao, Y.
Wang, F.
Wang, J.
Powiązania:
https://bibliotekanauki.pl/articles/351636.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
longitudinal crack
visual detection
image processing
continuous casting
Opis:
Based on the mould temperature measured by thermocouples during slab continuous casting, a difference of temperature thermograph is developed to detect slab cracks. In order to detect abnormal temperature region caused by longitudinal crack, the suspicious regions are extracted and divided by virtue of computer image processing algorithms, such as threshold segmentation, connected region judgement and boundary tracing. The abnormal regions are then determined and labeled with the eight connected component labeling algorithm. The boundary of abnormal region is also extracted to depict characteristics of longitudinal crack. Based on above researches, longitudinal crack with abnormal temperature region can be detected and is different from other abnormalities. Four samples of temperature drop are picked up to compare with longitudinal crack on the abnormal region formation, length, width, shape, et al. The results show that the abnormal region caused by longitudinal crack has a linear and vertical shape. The height of abnormal region is more than the width obviously. The ratio of height to width is usually larger than that of other temperature drop regions. This method provides a visual and easy way to detect longitudinal crack and other abnormities. Meanwhile it has a positive meaning to the intelligent and visual mould monitoring system of continuous casting.
Źródło:
Archives of Metallurgy and Materials; 2018, 63, 2; 673-680
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimal control strategy for marine SSP podded propulsion motor based on strong tracking-EPF
Autorzy:
Yao, W.
Liu, Y.
Sun, H.
Zhang, G.
Zhang, J.
Zhou, M.
Sun, M.
Jiang, D.
Powiązania:
https://bibliotekanauki.pl/articles/258784.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
marine electric propulsion
EPF
ST-EPF
SSP podded propulsion
propulsion motor
Opis:
Aiming at the non-linearity of state equation and observation equation of SSP (Siemen Schottel Propulsor) propulsion motor, an improved particle filter algorithm based on strong tracking extent Kalman filter (ST-EKF) was presented, and it was imported into the marine SSP propulsion motor control system. The strong tracking filter was used to update particles in the new algorithm and produce importance densities. As a result, the problems of particle degeneracy and sample impoverishment were ameliorated, the propulsion motor states and the rotor resistance were estimated simultaneously using strong track filter (STF), and the tracking ability of marine SSP propulsion motor control system was improved. Simulation result shown that the improved EPF algorithm was not only improving the prediction accuracy of the motor states and the rotor resistance, but also it can satisfy the requirement of navigation in harbor. It had the better accuracy than EPF algorithm.
Źródło:
Polish Maritime Research; 2015, S 1; 4-9
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System and Method for Simultaneous Measurement of Nitrogen Content and Uniformity of Nitration of Nitrocellulose
Autorzy:
Liu, Y.
Shao, Z.
Wang, W.
Li, W.
Lv, Y.
Sun, J.
Powiązania:
https://bibliotekanauki.pl/articles/358714.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
nitrocellulose
uniformity of nitration
nitrogen content
mixed acid nitration
cotton maturity
Opis:
Nitrocellulose (NC) is a common, commercially available, cellulosederived material and has been functionalized and widely applied in microfluidic technology, immunoassays and biochemical analyses. However, existing testing parameters always fail to completely and accurately reflect its inherent quality. In this study, we have designed and assembled a novel automatic polarizing microscope test system (PMTS) to scientifically test the nitrogen content and uniformity of nitration of NC based on the chromogenic principle of a polarization microscope. The advantages of this system are: (i) the PMTS requires less sample (only a few micrograms); (ii) the test period is shorter and the results can be obtained within 20 min; (iii) the method belongs to the nondestructive testing group, and the NC sample is not burned, dissolved, or damaged; and (iv) this method has increased accuracy, and the deviation of the nitrogen content is less than ±0.05%. The properties of various NC samples prepared by different nitricsulfuric acid systems from raw materials with diverse maturities were determined via PMTS. Five NC samples with different nitrogen contents (10.9%, 11.5%, 11.8%, 12.6% and 13.5%) were tested, and the variance of the corresponding uniformity of nitration of these samples were 3.17, 1.61, 1.15, 1.76, and 2.83. The uniformity of nitration initially decreased and then increased with increasing nitrogen content, and the best uniformity of nitration appeared at a nitrogen content of 12%. We also found that fibre maturity has a positive effect on the uniformity of nitration. This testing device and method, with its cost-effectiveness and field-portability, can significantly improve the accuracy of nitration content and uniformity, and has an important value in practical applications.
Źródło:
Central European Journal of Energetic Materials; 2018, 15, 4; 554-571
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermally Induced Polymorphic Transformation of Hexanitrohexaazaisowurtzitane (HNIW) Investigated by in-situ X-ray Powder Diffraction
Autorzy:
Liu, Y.
Li, S.
Wang, Z.
Xu, J.
Sun, J.
Huang, H.
Powiązania:
https://bibliotekanauki.pl/articles/358065.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
HNIW
polymorphism
in situ X-ray diffraction
phase transition
heat stimulation
Opis:
The ε→γ phase transition of HNIW induced by heat was investigated with in situ X-ray powder diffraction (PXRD). The effects of purity, particle size, insensitive additives and the time of isothermal heat treatment on the phase transition were evaluated. It was found that the phase transition is irreversible with changes in temperature, and the two phases can coexist in a certain temperature range. Moreover, the initial phase transition temperature increases with increasing purity and decreasing particle size of HNIW, and thus with the approximate crystal density. The addition of graphite and paraffin wax to HNIW as insensitive additives leads to a decrease in the initial phase transition temperature, but the addition of TATB does not affect the initial phase transition temperature. Thus, TATB is a suitable insensitive additive. Moreover, at the critical temperature, the isothermal time determined the efficiency of the ε- to γ-phase transition. This work lays the foundations for the choice of molding technologies, performance test methods, ammunition storage options, as well as the manufacture of HNIW-based explosive formulations.
Źródło:
Central European Journal of Energetic Materials; 2016, 13, 4; 1023-1037
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensitive detection of acetylene by second derivative spectra with tunable diode laser absorption spectroscopy
Autorzy:
Deng, H.
Sun, J.
Li, P.
Liu, Y.
Yu, B.
Li, J.
Powiązania:
https://bibliotekanauki.pl/articles/174963.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
tunable diode laser absorption spectroscopy
TDLAS
signal processing
Savitzky–Golay filter
trace gas detection
Opis:
A tunable diode laser absorption spectrometer was developed for trace acetylene gas analysis, the system performance was evaluated by combing an appropriate digital signal processing methods, i.e., Savitzky–Golay smoothing and differentiation algorithm. The calculation of the derivative spectra by this method is accompanied by simultaneous data smoothing. Based on the 2nd deriv- ative spectra detection method, the Allan variance technique indicates a C2H2 detection limit of 1.7ppm for 1-s averaging time, and a minimum noise level of 62ppb (parts per billion), at the optimum integration time of ~60s. The calculated 2nd derivative spectra with better resolution, lower detection limits, save signal processing time, and improve the ability to distinguish unresolved spectral signals.
Źródło:
Optica Applicata; 2016, 46, 3; 353-363
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of experimental infections of various Tembusu virus strains isolated from geese, ducks and chickens on ducklings
Autorzy:
Xu, T.
Huang, X.
Li, Y.
Liu, Q.
Liu, X.
Han, K.
Liu, Y.
Yang, J.
Zhao, D.
Bi, K.
Sun, W.
Powiązania:
https://bibliotekanauki.pl/articles/2087719.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
goose-derived
duck-derived
chicken-derived
Tembusu virus
pathogenicity
Źródło:
Polish Journal of Veterinary Sciences; 2018, 21, 2; 389-396
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies