Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wei, Y. Q." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Design of Acoustic Tubes Array and Application to Measuring Acoustic Loads in Supersonic Airflow
Autorzy:
Wei, L.
Li, M.
Fu, Q.
Fan, Y.
Yang, D.
Powiązania:
https://bibliotekanauki.pl/articles/176750.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic load
acoustic tubes array
near field measurement
supersonic airflow
Opis:
In the acoustic fatigue experiment for hypersonic vehicle in simulated harsh service environment on ground, acoustic loads on the surface of test pieces of the vehicle need to be measured. However, for the normal microphones without high temperature resistance ability, the near field sound measurement cannot be achieved. In this work, on the basis of previous researches, an acoustic tubes array is designed to achieve the near field measurement of acoustic loads on the surface of the test piece in the supersonic airflow with high temperature achieved by coherent jet oxygen lance. Firstly, the process of designing this acoustic tubes array is introduced. Secondly, the equality of phase differences at the front and at the end of the tubes is stated and proved using a phase differences test with an acoustic tubes array whose design is presented in this text; therefore, the phase differences of signals acquired by microphones can be directly applied to beamforming algorithm to determine the acoustic load source. Finally, using above mentioned acoustic tubes array, measurement of acoustic load, with and without a test piece in the supersonic airflow made by the coherent jet oxygen lance, is conducted respectively, and the measurements results are analyzed.
Źródło:
Archives of Acoustics; 2014, 39, 3; 395-402
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biomechanical evaluation of tendon connection with novel suture techniques
Autorzy:
Chen, Z.
Wang, J.
Wei, J.- S.
Hou, Z.-Y.
Li, M.
Chen, Q.-X
Powiązania:
https://bibliotekanauki.pl/articles/306902.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ścięgno Achillesa
IFLL
biomechanika
internal fixation with limited loop
Achilles tendon
biomechanics
Opis:
Achilles tendon rupture is a severe injury with poor curative effect due to its anatomical characteristic and mechanical peculiarity. Internal fixation of limited loop (IFLL) with steel-wire has been applied on patients with tendon rupture to fix the broken ends before physical rehabilitation. The purpose of this study is to investigate the biomechanical property and radiological characteristic of such suture technique for the repairment of tendon rupture. Methods: Tendons of pigs’ hint feet were separated for the biomechanical study. Suture surgery was performed according to the protocol of IFLL. Biomechanical Testing Machine was adopted to conduct the biomechanical tensile load examination. The maximal load, elastic modulus and tendon stiffness of the stitched tendons with or without reinforcement were examined. Results: The maximum tensile load of the stitched tendons using IFLL reached 1/4 of the uninjured tendon’s maximum tensile load, indicating that such suture technique is capable of providing enough tension for the ruptured tendon. Surprisingly, tendons fixed with titanium wire showed the highest load tension, which was comparable to the undamaged tendon. Therefore, we found the biomechanical basis of using IFLL in effectively connecting the rupture ends of tendons. Conclusions: In conclusion, we provide biomechanical evidence for the use of IFLL in treatment of Achilles tendon rupture, by providing enough strength for the ankle function. Such suture technique could help the patients with better rehabilitation and reduced in-hospital stay after Achilles tendon injury.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 1; 135-141
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies