Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Sadowski, R." wg kryterium: Autor


Wyświetlanie 1-7 z 7
Tytuł:
Research on interactions of plasma streams with CFC targets in the Rod Plasma Injector facility
Autorzy:
Zaloga, D. R.
Kwiatkowski, R.
Skladnik-Sadowska, E.
Sadowski, M. J.
Nowakowska-Langier, K.
Powiązania:
https://bibliotekanauki.pl/articles/146642.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
CFC target
optical spectroscopy
plasma streams
plasma-target interaction
Opis:
This paper present results of optical spectroscopy studies of interactions of intense plasma streams with a solid target made of carbon fibre composite (CFC). The experiments were carried out within the Rod Plasma Injector (RPI) IBIS facility. The optical measurements were performed first for a freely propagating plasma stream in order to determine the optimal operational parameters of this facility. Optical emission spectra (OES) were recorded for different operational modes of the RPI IBIS device, and spectral lines were identified originating from the working gas (deuterium) as well as some lines from the electrode material (molybdenum). Subsequently, optical measurements of plasma interacting with the CFC target were performed. In the optical spectra recorded with the irradiated CFC samples, in addition to deuterium and molybdenum lines, many carbon lines, which enabled to estimate erosion of the investigated targets, were recorded. In order to study changes in the irradiated CFC samples, their surfaces were analysed (before and after several plasma discharges) by means of scanning electron microscope (SEM) and energy dispersive spectroscopy (EDS) techniques. The analysis of the obtained SEM images showed that the plasma irradiation induces noticeable changes in the surface morphology, for example vaporisation of some carbon fi bres and formation of microcracks. The obtained EDS images showed that upon the irradiated target surface, some impurity ions are also deposited, particularly molybdenum ions from the applied electrodes.
Źródło:
Nukleonika; 2016, 61, 2; 179-183
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of fast electron beams and soft X-ray emission from plasma-focus experiments
Autorzy:
Surała, W.
Sadowski, M. J.
Kwiatkowski, R.
Jakubowski, L.
Żebrowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/147850.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electron beams
X-ray emission
plasma focus
hot spots
Opis:
The paper reports results of the recent experimental studies of pulsed electron beams and soft X-rays in plasma-focus (PF) experiments carried out within a modifi ed PF-360U facility at the NCBJ, Poland. Particular attention was focused on time-resolved measurements of the fast electron beams by means of two different magnetic analyzers, which could record electrons of energy ranging from about 41 keV to about 715 keV in several (6 or 8) measuring channels. For discharges performed with the pure deuterium fi lling, many strong electron signals were recorded in all the measuring channels. Those signals were well correlated with the fi rst hard X-ray pulse detected by an external scintillation neutron-counter. In some of the analyzer channels, electron spikes (lasting about dozens of nanoseconds) and appearing in different instants after the current peculiarity (so-called current dip) were also recorded. For several discharges, fast ion beams, which were emitted along the z-axis and recorded with nuclear track detectors, were also investigated. Those measurements confi rmed a multibeam character of the ion emission. The time-integrated soft X-ray images, which were taken side-on by means of a pinhole camera and sensitive X-ray fi lms, showed the appearance of some fi lamentary structures and so-called hot spots. The application of small amounts of admixtures of different heavy noble gases, i.e. of argon (4.8% volumetric), krypton (1.6% volumetric), or xenon (0.8% volumetric), decreased intensity of the recorded electron beams, but increased intensity of the soft X-ray emission and showed more distinct and numerous hot spots. The recorded electron spikes have been explained as signals produced by quasi-mono-energetic microbeams emitted from tiny sources (probably plasma diodes), which can be formed near the observed hot spots.
Źródło:
Nukleonika; 2016, 61, 2; 161-167
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Recent ion measurements within the modified DPF-1000U facility
Autorzy:
Kwiatkowski, R.
Czaus, K.
Skladnik-Sadowska, E.
Sadowski, M. J.
Zaloga, D. R.
Paduch, M.
Zielinska, E.
Powiązania:
https://bibliotekanauki.pl/articles/148249.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
DPF-1000U facility
ion beams
ion energy spectra
ion pinhole images
Opis:
In this note we describe measurements of ion beams emitted along the z-axis of the DPF-1000U facility operated at 23 kV, 334 kJ, and with the initial deuterium pressure of 1.6–2 hPa. The DPF-1000U device was recently renewed and equipped with a dynamic gas-puff valve placed inside the inner electrode. The investigated ions were recorded by means of ion pinhole cameras equipped with solid state nuclear track detectors of the PM-355® (PADC) type. The energy spectra of ions were determined using a Thomson spectrometer placed on the symmetry axis at a distance of 160 cm from the electrodes outlets. The ion images recorded during discharges performed under different experimental conditions show that the ion beams have a complex structure, usually in the form of a central bunch and an annular stream composed of many micro-beams. Energies of the registered deuterons have been in the range of 30–700 keV, while the fast protons (which originated from the hydrogen remnants) had energies in the range of 300–850 keV.
Źródło:
Nukleonika; 2015, 60, 2; 297-302
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on spatial and energetic characteristics of the ion beams emitted in the PF - 360 discharges
Autorzy:
Kwiatkowski, R.
Skladnik-Sadowska, E.
Malinowski, K.
Sadowski, M. J.
Czaus, K.
Zebrowski, J.
Garkusha, I. E.
Powiązania:
https://bibliotekanauki.pl/articles/147918.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ion beams
PF-360 facility
ion pinhole images
Opis:
Experimental results are presented on the spatial structure and energetic characteristics of the fast ion beams produced by high-current discharges in a PF-360 device operated at the National Centre for Nuclear Research (NCBJ, Otwock/Świerk, Poland). The 105 kJ discharges were initiated at the initial deuterium pressure around p0 = 6 hPa and were powered from a 234 miF capacitor bank charged up to 30 kV. The spatial structure of the ion beams was recorded using pinhole cameras equipped with the solid-state nuclear track detectors of the PM-355 type, placed at two different angles (0 centigrade, 45 centigrade) relative to the discharge axis. The detectors were shielded by thin absorption filters made of pure Al foils of various thickness, which made it possible to record only ions with energies exceeding a chosen threshold value. Similarly as in other plasma focus (PF) experiments, energies of the emitted ions ranged from about 30 keV to about 3 MeV, i.e. they were much higher than the voltage applied to the electrodes. The recorded ion images showed a complex spatial structure of the fast ion beams, which consisted of many micro-beams of different energies. It is possible that these beams were emitted by various local micro-sources (e.g. plasma micro-diodes) the were formed inside the PF pinch column.
Źródło:
Nukleonika; 2012, 57, 1; 67-74
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time - and space - resolved measurements of high - energy ion beams emitted from PF - type discharges
Autorzy:
Kwiatkowski, R.
Sadowski, M. J.
Skladnik-Sadowska, E.
Zebrowski, J.
Malinowski, K.
Czaus, K.
Garkusha, I. E.
Powiązania:
https://bibliotekanauki.pl/articles/147518.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ion beams
miniature scintillation detectors
PF-360 facility
Opis:
The paper presents experimental studies of the spatial-microstructure and temporal-characteristics of fast ion beams, which are emitted from high-current plasma-focus (PF) discharges performed within the PF-360 facility at National Centre for Nuclear Research (NCBJ) at Otwock/Świerk, Poland. The spatial structure of the ion beams was investigated by means of pinhole cameras equipped with solid-state nuclear track detectors shielded by absorption filters made of Al-foils of different thickness. In order to perform time-resolved measurements there were applied miniature scintillation detectors placed at different points of the ion-image plane.
Źródło:
Nukleonika; 2012, 57, 2; 211-214
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of optical spectra recorded during DPF-1000U plasma experiments with gas-puffing
Autorzy:
Zaloga, D. R.
Skladnik-Sadowska, E.
Kubkowska, M.
Ladygina, M. S.
Malinowski, K.
Kwiatkowski, R.
Sadowski, M. J.
Paduch, M.
Zielinska, E.
Makhlaj, V. A.
Powiązania:
https://bibliotekanauki.pl/articles/147780.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electron density
gas-puff
optical spectrum
plasma focus
plasma stream
Opis:
The results are presented of the optical spectra measurements for free plasma streams generated with the use of the modifi ed DPF-1000U machine. This facility was recently equipped with a gas injection system (the so-called gas-puff) placed on the symmetry axis behind the central opening in the inner electrode. The DPF-1000U experimental chamber was fi lled up with pure deuterium at the initial pressure of 1.6 or 2.4 mbar. Additionally, when the use was made of the gas-puff system about 1 cm3 of pure deuterium was injected at the pressure of 2 bars. The gas injection was initiated 1.5 or 2 ms before the triggering of the main discharge. The investigated plasma discharges were powered from a condenser bank charged initially to 23 kV (corresponding to the energy of 352 kJ), and the maximum discharge current amounted to about 1.8 MA. In order to investigate properties of a dense plasma column formed during DPF-1000U discharges the use was made of the optical emission spectroscopy. The optical spectra were recorded along the line of sight perpendicular to the vacuum chamber, using a Mechelle®900 spectrometer. The recent analysis of all the recorded spectra made it possible to compare the temporal changes in the electron density of a freely propagating plasma stream for discharges without and with the gas-puffing. Using this data an appropriate mode of operation of the DPF-1000U facility could be determined.
Źródło:
Nukleonika; 2015, 60, 2; 309-314
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of electron and ion beams emitted from the PF-1000 device in the upstream and downstream direction
Autorzy:
Kwiatkowski, R.
Skladnik-Sadowska, E.
Malinowski, K.
Sadowski, M. J.
Czaus, K.
Zebrowski, J.
Karpinski, L.
Paduch, M.
Scholz, M.
Garkusha, I. E.
Kubeš, P.
Powiązania:
https://bibliotekanauki.pl/articles/146626.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electron beam (EB)
ion beams
PF-1000 facility
magnetic analyzer
ion pinhole cameras (IPC)
Opis:
In this paper we report on measurements of the energy spectra and other properties of the electron and fast ion beams emitted in the upstream and downstream direction along the z-axis of a large plasma focus device PF-1000, that was operated at 21-27 kV, delivering 290–480 kJ pulse. Measurements of the electron beam (EB) properties were performed using a magnetic analyzer. Properties of the ion beams were measured by means of pinhole cameras equipped with PM-355 nuclear track detectors and placed at various angles (0, 60 and 180 centigrade) to the discharge axis. Measurements revealed a complex spatial structure of the fast ion beams. The ion measurements behind the PF-1000 collector proved that some fast deuterons are emitted also in the upstream direction. Measurements of the EBs emitted in the upstream and downstream direction revealed electron energies in the range from approximately 40 keV to approximately 800 keV. These spectra confirm that in localized regions within the PF-1000 plasma column there appear strong fields accelerating charged particles in different directions along the discharge axis.
Źródło:
Nukleonika; 2011, 56, 2; 119-123
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies