Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Różyc." wg kryterium: Autor


Wyświetlanie 1-7 z 7
Tytuł:
Digital-to-Time Converter for pulse train generation based on Look-Up Tables in FPGA
Autorzy:
Kwiatkowski, P.
Różyc, K.
Szplet, R.
Powiązania:
https://bibliotekanauki.pl/articles/114335.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Digital-to-Time Converter
time interval generator
programmable delay line
programmable devices
Opis:
A Digital-to-Time Converter (DTC) is presented which allows to generate pulse train with resolution of 250 ps within 32 ns operation range. The converter is implemented in off-the-shelf Spartan-6 Field-Programmable Gate Array (FPGA) device, manufactured by Xilinx in 45 nm CMOS technology. The design is implemented with the use of Look-Up Tables (LUT) as delay elements. “Manual” Place and Route (P&R) process was involved to improve conversion linearity. Developed DTC can be used to improve the functionality of time interval generators.
Źródło:
Measurement Automation Monitoring; 2018, 64, 1; 14-16
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Scalony licznik czasu z użyciem stempli czasowych i interpolacji dwustopniowej
An integrated time counter based on timestamps and two-stage interpolation
Autorzy:
Kwiatkowski, P.
Szplet, R.
Jachna, Z.
Różyc, K.
Powiązania:
https://bibliotekanauki.pl/articles/157252.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
układy programowalne
przetworniki czasowo-cyfrowe
metoda stempli czasowych
interpolacja dwustopniowa
programmable device
time-to-digital converters
time stamps method
two-stage interpolation
Opis:
W artykule opisano budowę i działanie licznika czasu opartego na metodzie stempli czasowych i dwustopniowej interpolacji. Licznik został zaimplementowany w układzie programowalnym FPGA Kintex-7 firmy Xilinx. Pokazano sposób tworzenia stempli czasowych o wysokiej rozdzielczości oraz opisano problemy projektowe pojawiające się podczas implementacji projektu w układzie FPGA. Opracowany licznik charakteryzuje się wysoką rozdzielczością (< 11,6 ps) i precyzją (< 12 ps) oraz dużą szybkością powtarzania pomiarów (do 12 milionów pomiarów na sekundę). Słowa kluczowe: układy programowalne, przetworniki czasowo-cyfrowe, metoda stempli czasowych, interpolacja dwustopniowa.
This paper presents an integrated time counter based on timestamps and two-stage interpolation methods implemented in an FPGA programmable device. The timestamps method [2, 3] is useful, among others, in physical experiments and laser ranging systems [2, 4, 5]. To obtain high (picoseconds) resolution, it can be combined with the Nutt interpolation method [1, 6]. The principle of measurement is described in Section 2 and shown in Fig. 1. The time counter contains a period counter, a period counter register and 8 independent channels (Fig. 2, Section 3). Each channel consists of a multiphase clock generator, first and second interpolation stage modules and a channel register. The principle of operation and the way of implementing them in a Kintex-7 FPGA device (Xilinx) [7] are also presented in Section 3. The time counter was examined in terms of resolution and precision for each measurement channel (Section 4). The resolution was evaluated using the statistical code density test [8] and its value was below 12 ps. In Fig. 3 there is shown the time counter precision. In the range up to 1 ms it does not exceed 12 ps. For longer time intervals the precision is worsened by the limited stability of the reference clock. The maximum measurement rate for a single channel was experimentally estimated as 12 million measurements per second. The presented time counter is characterized by high metrological parameters (due to the interpolation method) and wide functionality (due to the time stamps).
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 7, 7; 435-437
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parallel data processing in a 3-channel integrated time-interval counter
Autorzy:
Jachna, Z.
Szplet, R.
Kwiatkowski, P.
Różyc, K.
Powiązania:
https://bibliotekanauki.pl/articles/114531.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
programmable device
time-to-digital converters
interpolating time counters
parallel data processing
Opis:
In this paper, we discuss an issue of parallel data processing in multichannel time interval counters (TICs). Particularly we analyze this problem within the framework of a 3-channel TIC developed for the international project Legal Time Distribution System (LTDS). The TIC provides the high measurement precision (< 15 ps) and wide range (> 1s) that are obtained by combining reference clock period counting with in-period interpolation. A measurement process consists of three main stages: (1) events registration, (2) data processing and (3) data transfer. In the event registration stage all input events are identified and registered with related unique timestamps based on a consistent time scale. To achieve high measurement precision, the stream of timestamps is then processed using actual transfer characteristics of the TIC and offset values of all measurement channels. We describe the concept of parallel data processing and its implementation in a Spartan-6 FPGA device (XC6SLX75, Xilinx).
Źródło:
Measurement Automation Monitoring; 2015, 61, 7; 308-310
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Procesor kodu do realizacji procedur kalibracyjnych w interpolacyjnym liczniku czasu
A code processor for realization of calibration procedures in an interpolating time counter
Autorzy:
Jachna, Z.
Szplet, R.
Kwiatkowski, P.
Różyc, K.
Powiązania:
https://bibliotekanauki.pl/articles/151466.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
układy programowalne
przetworniki czasowo-cyfrowe
interpolacyjny licznik czasu
programmable device
time-to-digital converters
interpolating
time counter
Opis:
W artykule opisano projekt procesora kodu (PK) stanowiącego fragment dwukanałowego precyzyjnego licznika czasu z niezależnymi interpolatorami dwustopniowymi. Projekt został zrealizowany w układzie programowalnym XC6SLX75 (Xilinx). Zadaniem układów PK jest wykonywanie kalibracji linii kodujących, w wyniku której następuje aktualizowanie charakterystyk przetwarzania i w efekcie zwiększenie precyzji pomiarowej licznika. Dzięki sprzętowej implementacji algorytmów kalibracyjnych uzyskuje się skrócenie czasu wykonywania kalibracji, zmniejszenie liczby danych przesyłanych do komputera oraz zmniejszenie złożoności oprogramowania sterującego.
In the paper there is presented a design of a code processor (PK) as a part of a 2-channel precise time counter with independent 2-stage interpolators. The project was implemented in Spartan-6 (Xilinx) FPGA device. The main task of the PK is calibration of coding lines, resulting in updating transfer characteristics and, as an effect, higher measurement precision of the counter. Thanks to the hardware implementation of calibration algorithms there are achieved: the shorter execution time of calibration procedures, the lower amount of data transferred into the computer and less complex control software. The first simple realization of the PK has been implemented using Spartan-3 device (Xilinx) [8]. This paper presents a new, improved realization of the PK whose characteristic is more suited for the newest counters and those to be invented in the future. The use of VHDL language for description of the PK makes it more susceptible to be adapted. This paper consists of description of the counter with advanced architecture of interpolators [7] , where 10 independent time coding lines where implemented in each measurement channel. The operating principle of the PK is described based on the following scheme: precise description of code density test realization, the way of forming the transfer characteristic and the results calculations.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 7, 7; 438-440
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A multichannel programmable distribution amplifier
Autorzy:
Różyc, K.
Kwiatkowski, P.
Sawicki, M.
Jachna, Z.
Szplet, R.
Powiązania:
https://bibliotekanauki.pl/articles/114493.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
programmable device
distribution amplifier
Opis:
This paper presents the design, operation and test results of a multichannel programmable distribution amplifier. The distributor is based on a reprogrammable device Spartan-6 FPGA (Xilinx) and is intended to distribute a 10 MHz or 5 MHz frequency reference signal as well as 1 PPS pulses. It is built in a 2U, 19” rack-mount enclosure and is equipped with a single optical and seven electrical inputs, as well as two optical and fourteen electrical outputs The transition time and additive jitter of the distribution amplifier were tested and they did not exceed 14 ns and 4.5 ps RMS (for electrical inputs/outputs), respectively. In the case of optical input/outputs, the results depend on the parameters of converters involved. The values of delays and jitter introduced by the distributor are slightly larger than for dedicated integrated circuits, but the advantage of this solution is the possibility to build signal distributors with a larger number of inputs/outputs and the ease to modify and meet requirements of various applications.
Źródło:
Measurement Automation Monitoring; 2015, 61, 7; 314-316
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
5 ps Jitter Programmable Time Interval/Frequency Generator
Autorzy:
Kwiatkowski, P.
Różyc, K.
Sawicki, M.
Jachna, Z.
Szplet, R.
Powiązania:
https://bibliotekanauki.pl/articles/221151.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
time interval generator
digital-to-time converter
DDS synthesizer
phase shifting
FPGA
Opis:
A new time interval/frequency generator with a jitter below 5 ps is described. The time interval generation mechanism is based on a phase shifting method with the use of a precise DDS synthesizer. The output pulses are produced in a Spartan-6 FPGA device, manufactured by Xilinx in 45 nm CMOS technology. Thorough tests of the phase shifting in a selected synthesizer are performed. The time interval resolution as low as 0.3 ps is achieved. However, the final resolution is limited to 500 ps to maximize precision. The designed device can be used as a source of high precision reference time intervals or a highly stable square wave signal of frequency up to 50 MHz.
Źródło:
Metrology and Measurement Systems; 2017, 24, 1; 57-68
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wielokanałowy modułowy licznik czasu z użyciem układów programowalnych
A modular multi-channel time counter using programmable devices
Autorzy:
Różyc, K.
Szplet, R.
Kwiatkowski, P.
Sawicki, M.
Jachna, Z.
Powiązania:
https://bibliotekanauki.pl/articles/158352.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
układy programowalne
przetworniki czasowo-cyfrowe
licznik czasu
interpolacja dwustopniowa
time counter
programmable device
time-to-digital converter
two-stage interpolation
Opis:
Przedstawiono budowę, zasadę działania i wyniki badań wielokanałowego modułowego licznika czasu. Umożliwia on równoczesny pomiar relacji czasowych pomiędzy impulsami wejściowymi (START), pochodzącymi z maksymalnie sześciu niezależnych źródeł zegarowych, a wspólnym dla wszystkich kanałów impulsem odniesienia (STOP). Moduły pomiarowe licznika wykonano z użyciem układów programowalnych FPGA Spartan-3 (Xilinx). Licznik charakteryzuje się zakresem pomiarowym do 1 s oraz precyzją pomiarów nie gorszą niż 250 ps.
We present the design, operation and test results of a modular multichannel time counter built with the use of programmable devices. Its resolution is below 50 ps and the measurement range reaches 1 sec. The design of the counter is shown in Fig. 1. It consists of six independent measurement modules. Each measurement module contains a 2-channel time interval counter (Fig. 2) implemented in a general-purpose reprogrammable device Spartan-3 (Xilinx). To obtain both high precision and wide measurement range, the counting of periods of a reference clock is combined with a two-stage interpolation within a single period of the clock signal [6]. The interpolation involves a four-phase clock in the first interpolation stage [8] and a time delay coding line in the second interpolation stage. The reference clock module contains an integrated digital synthesizer [7], that provides the reference clock signal of 250 MHz for measurement modules, and is driven by an external clock source of 5 MHz or 10 MHz. The standard measurement uncertainty of the time counter was tested (Figs. 3 and 4) carefully and it did not exceed 250 ps in the full measurement range. As the acid test of the time counter, the differences between signals of 1 PPS from the tested clock sources and the reference 1 PPS signal were also verified (Figs. 5 and 6). The modular design makes the multi-channel time counter easy to modify to meet requirements of various applications.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 7, 7; 432-434
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies