Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "spektroskopia Ramana." wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
The control software of the portable Raman spectrometer
Oprogramowanie sterujące przenośnym spektrometrem Raman
Autorzy:
Kwiatkowski, A.
Smulko, J.
Powiązania:
https://bibliotekanauki.pl/articles/266476.pdf
Data publikacji:
2011
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
spektroskopia Ramana
identyfikacja
Raman spectroscopy
identification
Opis:
The paper contains a description of the control software of a portable Raman spectrometer which was built in the Department of Optoelectronics and Electronic Systems Faculty of Electronics, Telecommunications and Informatics Gdansk University of Technology. The software has modular structure, which includes the laser control module and the spectrum acquisition module (laser power selection, working mode and data acquisition time) was described. The module of Raman spectra pre-processing (smoothing, background removal, normalization) was described in detail, with particular emphasis on its ergonomic use. The software was prepared for two different user types (experienced and inexperienced), allowing use by the advanced operator or by the less experienced personnel. The Raman spectra database with updating ability by external databases was presented, together with the selected identification algorithms.
Praca zawiera opis oprogramowania sterującego przenośnym spektrometrem Ramana, który został zbudowany w Katedrze Optoelektroniki i Systemów Elektronicznych Wydziału Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej, w trakcie realizacji grantu rozwojowego. Opisano modułową budowę oprogramowania, zawierającego moduł sterujący pracą laserów oraz procesem akwizycji widma. Bardziej szczegółowo przedstawiono moduły realizujące funkcje wstępnego przetwarzania widm Ramana, ze szczególnym uwzględnieniem ergonomii korzystania z urządzenia w warunkach pomiarów w terenie. Oprogramowanie zrealizowano w koncepcji dwóch użytkowników (zaawansowany i podstawowy), umożliwiając tym samym obsługę urządzania przez doświadczonych operatorów oraz przez personel o ograniczonych kwalifikacjach. Przedstawiono także budowę bazy danych widm Ramana. Scharakteryzowano również algorytmy dokonujące identyfikacji widm.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2011, 30; 81-84
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytmy przetwarzania widm Ramana podczas detekcji substancji chemicznych
Algorithms of Raman spectra processing during chemicals detection
Autorzy:
Kwiatkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/267815.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
spektroskopia Ramana
algorytmy detekcji
zakłócenia
Raman spectroscopy
detection algorithms
noise
Opis:
W pracy zostaną przedstawione algorytmy wstępnego przetwarzania widm mające na celu usuniecie lub zmniejszenie intensywności zakłóceń obecnych w rejestrowanych widmach Ramana, ze szczególnym uwzględnieniem automatyzacji tego procesu (bez konieczności wyboru parametrów przetwarzania przez obsługę urządzenia). Kolejna prezentowana grupę algorytmów stanowią procedury parametryzacji widm, które opisują widma w postaci zbioru kilku parametrów, np. pozycji linii widmowych, jej względnej amplitudy oraz szerokości. Parametry te są niezbędną informacja wejściową dla niektórych algorytmów detekcji. W pracy zostaną również zaprezentowane najpopularniejsze algorytmy korelacyjne oraz algorytmy porównujące położenie i amplitudę linii widmowych.
Detection of chemicals on the basis of their Raman spectra measurement consists in comparison recorded spectra for the tested chemical substances with model spectra stored in the master database. Detection algorithms indicate the substance of the database whose spectrum is the most similar, according to established criteria, to the recorded spectrum of the tested chemical. In the paper, there will be presented spectra preprocessing algorithms to eliminate or reduce the intensity of the noise present in the recorded Raman spectra, with particular emphasis on automation of this process (no need to select the parameters processed by the operation of the device). Another presented group of algorithms are spectra parameterization procedures that describe the spectrum as a set of several parameters, such as the position of the spectral lines, the relative amplitude and width. These parameters are necessary input information for some detection algorithms. The paper will also be presented to the most popular correlation algorithms.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 34; 39-42
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytmy wykrywania substancji chemicznych na podstawie pomiarów widm Ramana
Algorithms of chemicals detection using Raman spectra
Autorzy:
Kwiatkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/157567.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
algorytmy detekcji
zjawisko Ramana
spektroskopia Ramana
szumy
detection algorithms
Raman phenomena
Raman spectroscopy
noise
Opis:
Rejestracja widma promieniowania rozproszonego nieelastycznie podczas zjawiska Ramana, które jest charakterystyczne dla badanej substancji, pozwala na jej identyfikację. W pracy zostały przedstawione przykładowe widma Ramana substancji chemicznych. Następnie opisano błędy podczas pomiarów widm Ramana, powodujące ograniczenia możliwości identyfikacji substancji chemicznych lub ich mieszanin. Szczegółowo przedstawiono możliwości redukcji błędów pomiarowych przez zastosowanie procedur usuwania tła oraz wygładzania rejestrowanych widm we wstępnej fazie przetwarzania. W pracy następnie opisano wybrane algorytmy klasyfikacji, które umożliwiają wyznaczanie składu badanej mieszaniny na podstawie porównania jej widma Ramana z modelami stworzonymi na bazie widm wzorcowych. Ponadto oceniono efektywność wykrywania wybranych substancji chemicznych według przedstawionych metod oraz możliwości ich usprawnienia.
The Raman spectrometers are devices which allow immediate and accurate identification of the examined chemicals without a requirement of a direct contact. The devices are based on the Raman phenomenon, which takes place during illumination of the sample by a monochromatic radiation (e.g. 785 nm laser). Additional bands appear in the scattered spectrum due to the inelastic scattering of excitation monochromatic light on the molecules of the investigated probe. The number, shapes and locations of these bands in the Raman spectrum are unique for the investigated chemicals. Therefore, the irradiated probe can be identified. Raman spectrometers are used for rapid identification of unknown and potentially dangerous substances (e.g. drugs, explosives). The paper presents construction details of the portable Raman spectrometer being prepared at the Faculty of Electronics, Telecommunications and Informatics, Gdansk University of Technology. The paper outlines necessary signal processing to assure reliable identification. First interferences encountered during Raman spectra measurements are presented. Secondly, methods of their reduction (background removal, spectra smoothing) are described. The selected algorithms for chemicals classification are outlined. They enable determination of their composition by comparing the measured Raman spectra with the models based on the prepared spectra library. Finally, efficiency of these algorithms is discussed and directions of their further development are outlined.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 9, 9; 1081-1084
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Raman spectra measurements for chemical identification - aspect of uncertainty sources and reduction of their effects
Problemy pomiarów widm Ramana podczas identyfikacji substancji chemicznych
Autorzy:
Kwiatkowski, A.
Smulko, J.
Wierzba, P.
Powiązania:
https://bibliotekanauki.pl/articles/156092.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
zjawisko Ramana
spektroskopia Ramana
szumy
zakłócenia
etaloning
Raman phenomenon
Raman spectroscopy
noise
interference
etaloning effect
Opis:
Raman spectrometers enable fast and non-contact identification of examined chemicals. These devices measure Raman spectra and compare with the spectra database to identify unknown and often illicit chemicals (e.g. drugs, explosives) usually without any sample preparation. Raman spectra measurements are a challenge due to noise and interferences present outside the laboratories (field applications). The design of a portable Raman spectrometer developed at the Faculty of Electronics, Telecommunications and Informatics, Gdansk University of Technology is presented. The paper outlines sources of noise and interferences (e.g. background removal, spectra smoothing) contaminating Raman spectra measurements as well as signal processing techniques required to reduce their influence. The authors consider influence of packages (glass or plastic vials) on effectiveness of detection of selected chemical mixtures and they propose a method that reduces this factor. Next, the impact of acquisition time and external lighting on the accuracy of Raman spectra measurements is investigated. The synchronic detection is introduced to diminish changes of outside sample irradiation. Finally, the etaloning error present in the measured spectra is considered and attenuated by an additional procedure.
Spektroskopy Ramana umożliwiają szybką i bezkontaktową identyfikację badanej substancji chemicznej. Mierzą widma Ramana i porównują z biblioteką widm, aby identyfikować nieznaną, często nielegalną substancję chemiczną (np. narkotyki, materiały wybuchowe) bez potrzeby przygotowania badanej próbki. Pomiar widm Ramana w warunkach polowych jest dużym wyzwaniem ze względu na obecność wielu źródeł szumów i zakłóceń, m.in. szumy przetworników CCD, fluorescencja, szumy kosmiczne, oświetlenie zewnętrzne. W pracy przedstawiono projekt przenośnego spektrometru Ramana opracowanego na Wydziale Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej. Opisano źródła szumów i zakłóceń obecnych podczas pomiarów widm Ramana oraz techniki przetwarzania sygnałów zmniejszające ich wpływ (np. usuwanie tła, widm wygładzanie). Autorzy rozważają także wpływ opakowań (szklanych lub plastikowych) na efektywność detekcji wybranych mieszanin chemicznych i proponują metodę, pozwalającą na jego redukcję. Następnie przedstawiono zależności między czasem ekspozycji a dokładnością pomiarów widm Ramana. Określono skutki oddziaływania zewnętrznego (niepożądanego) oświetlenia na jakość pomiarów oraz przedstawiono sposób ich ograniczenia przy użyciu pomiarów synchronicznych. Następnie opisano zjawisko etaloningu oraz procedurę jego usunięcia w kontrolowanych warunkach pomiarowych, za pomocą dodatkowych procedur.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 12, 12; 1518-1521
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody usuwania zakłóceń podczas pomiarów polowych widm Ramana
Methods for noise reduction in Raman spectra in field measurements
Autorzy:
Kwiatkowski, A.
Smulko, J.
Powiązania:
https://bibliotekanauki.pl/articles/158047.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
spektroskopia Ramana
detekcja synchroniczna
szum biały
szum typu 1/f
Raman spectroscopy
synchronous detection
cosmic rays
white noise
1/f noise
Opis:
W pracy zostały scharakteryzowane źródła zakłóceń występujące podczas pomiarów widm Ramana w warunkach polowych oraz sposoby redukcji ich wpływu na jakość rejestrowanych widm. Zaprezentowano wpływ czasu integracji na jakość rejestrowanych widm w przypadkach, gdy szumy własne spektrometru mają składową typu 1/f, dominującą w zakresie małych częstotliwości. Przedstawiono także wyniki uzyskane podczas pomiarów z detekcją synchroniczną, stosowaną w przenośnych spektrometrach Ramana, w pomiarach przy silnym oświetleniu zewnętrznym.
Raman spectrometers are devices which allow immediate and contactless identification of the examined substances. Detection is possible without any sample preparation, even from a distance or via a transparent package, like glass or plastic vials. These features make the Raman spectra measurement technique popular. Therefore it requires continuous development to get better results. Chemicals detection is based on comparison of a registered Raman spectrum with the reference spectra stored in a database. The algorithm which compares the spectra indicates the substances (one or even a few) having the most similar (according to the applied criterion) spectrum to the Raman spectrum of the investigated chemical. The reference database is created in a laboratory by using precise Raman Spectrometers of high resolution and low noise level. Field measurements of the Raman spectra are usually made by a less accurate device and suffer from external interferences. Therefore an additional procedure for noise and interference dumping is necessary. The paper outlines the sources of noise and interference contaminating Raman spectra. The selected methods for their suppression are discussed. The advantage of synchronous detection measurements at ambient light is shown. Finally, the impact of the time integration on the spectra quality, when inherent noise of a spectrometer has a dominant 1/f component at low frequency range is described.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 4, 4; 281-283
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies