Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "oxidation process" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Pretreatment of Stabilized Landfill Leachate Using Ozone
Autorzy:
Kwarciak-Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/124499.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
landfill leachate
ozonation
hydrogen peroxide
ultrasonic field
advanced oxidation process
Opis:
The paper presents the possibility of using the ozonation process in landfill leachate pretreatment. The study was conducted in three stages. In the first stage, the landfill leachate was subjected only to the ozone, with the dose varying from 10 mg/dm3 to 40 mg/dm3. As part of this stage of research, the effect of changes in the pH of wastewater undergoing the process of ozonation on the efficiency of TOC removal was examined. For all the tested pH values (pH = 3.5, pH = 7 pH = 8.5 pH = 10), the TOC removal rate constant (kRowo) during ozonization was determined. In the second stage of the study, the ozonation process was facilitated by UV radiation. Additionally in this stage, the rate of generation of OH• radicals was accelerated by the addition of hydrogen peroxide to the reactor. The COD: H2O2 ratio by weight was 1:2.5, 1:5 and 1:10 and 1:20. In the last stage of the study, we attempted to assist the ozonation process using ultrasonic field. The employed vibration amplitude amounted to 25μm and sonication time equalled 300 seconds. It was found that the ozonation process is the most effective at alkaline pH (8.5). The TOC removal efficiency was 37% (346 mg/dm3) after 60 minutes of ozonation. The best results of pollutants oxidation measured as COD and TOC removal were observed when the dose of ozone was 20 mg/dm3. The combination of sonication and ozonation has resulted in a reduction of COD and TOC values by 370 mg/dm3 and 126 mg/3, respectively, in comparison to the ozonation process alone. It was found that the most effective process in landfill leachate treatment is the combination of ozonation with hydrogen peroxide addition (COD:H2O2=1:10). The COD, TOC and BOD values were 65%, 62% and 36% lower, respectively, in comparison to ozonation process conducted alone.
Źródło:
Journal of Ecological Engineering; 2018, 19, 5; 186-193
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie procesu ozonowania w oczyszczaniu ścieków koksowniczych
The Use of Ozonation Process in Coke Wastewater Treatment
Autorzy:
Kwarciak-Kozłowska, A.
Krzywicka, A.
Gałwa-Widera, M.
Powiązania:
https://bibliotekanauki.pl/articles/1818115.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
ścieki koksownicze
ozonowanie
zaawansowane metody utleniania
coke wastewater
ozonation
advanced oxidation process
Opis:
The paper presents presents the possibility of using the ozonation process in coke wastewater treatment. The wastewater produced during processing of coke was initially pre-treated mechanically in order to remove solid impurities, oils and tar substances. The raw wastewater was characterized by the phenolic odor, brown color and alkaline pH (pH 9.2). The COD value of raw wastewater was 8100 mg/dm3 and the value of BOD was very low (180 mg/dm3). A high concentration of total nitrogen (2420 mg/dm3) and TOC (2240 mg/dm3) was also noted. The study was conducted in three stages. In the first stage, coking wastewater was treated only by ozone, the dose of which varied from 10 mg/dm3 to 40 mg/dm3. The effect of pH during ozonation process was determined on TOC removal efficiency. For all of the pH values (pH = 3.5, pH = 7, pH = 8.5 and pH = 11.5) the TOC removal rate constant was determined. In the second stage, the rate OH radicals generation was accelerated by the addition of hydrogen peroxide to the reactor. The ratio by weight of COD: H2O2 was 1:2.5, 1:5, 1:10 and 1:20. In the last stage of the study, we attempted to assist the ozonation process with ultrasonic field. The sonication time was 8 minutes and the amplitude was 61.5 μm. It was found that the ozonation process is the most effective at alkaline pH (8.5). The TOC removal efficiency was 34% (1470 mg/dm3) after 60 minutes of ozonation. The best results of oxidation of pollutants measured as COD and TOC removal were observed when the dose of ozone was 30 mg/dm3.The combination of sonication and ozonation has resulted in a reduction of COD and TOC values by 1000 mg/dm3 and 300 mg/dm3, respectively, in comparison to ozonation process alone. It was found that the most effective process in coke wastewater treatment is the combination of ozonation with hydrogen peroxide addition (COD:H2O2=1:10). The COD, TOC and BOD value were 54%, 35% and 20% lower, respectively, in comparison to ozonation process conducted alone.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 61-73
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Application of Integrated System in Dairy Wastewater Treatment
Zastosowanie zintegrowanego system w oczyszczaniu ścieków mleczarskich
Autorzy:
Kwarciak-Kozłowska, A.
Gałwa-Widera, M.
Bień, J.
Powiązania:
https://bibliotekanauki.pl/articles/1813672.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
dairy wastewater
photocatalysis
TiO2
ZnO
advanced oxidation process
ultrafiltration
ścieki mleczarskie
fotokataliza
zaawansowane metody utleniania
ultrafiltracja
Opis:
The study presented the results of the examinations obtained during treatment of dairy wastewater in a membrane photoreactor where photocatalysis was sequentially combined with low-pressure membrane process. The aim of the study was to determine the effectiveness of degradation of the contaminants contained in such wastewater during photocatalysis and in the arrangement that combined photocatalysis with ultrafiltration. Several experiments were performed in order to determine the most beneficial conditions of the photocatalysis process, e.g. the dose of the photocatalysts used (TiO2 and ZnO), duration of the process and pH of wastewater subjected to oxidation. The dose of titanium dioxide was changed from 1 to 40 g/dm3, whereas the content of zinc oxide ranged from 1 to 6 g/dm3. The results obtained in the study showed that the extension of the irradiation time to over 30 minutes (TiO2) and over 45 minutes (ZnO) during photocatalysis does not lead to increased removal of contaminants from the dairy wastewater. It was also demonstrated that the increase in the doses of both photocatalysts does not lead to the increase in the efficiency of their treatment. In the case of treatment of dairy wastwater with TiO2, the photocatalysis occurred most effectively for its dose of 10 g/dm3. Removal rates for COD, TOC and total nitrogen were 58% (1670 mg/dm3), 62% (450 mg/dm3) and 56% (128 mg/dm3), respectively. Replacing titanium dioxide with zinc oxide (ZnO – 2 g/dm3) in the photocatalysis process allowed for obtaining higher degrees of removal of contaminants determined as COD, TOC and total nitrogen to the level of 77.8% (870 mg/dm3), 62% (445 mg/dm3) and 52% (139 mg/dm3), respectively. Since both photocatalysts were supplied to the photoreactor in the form of a suspension, the membrane in the next reactor represented an efficient barrier for their particles. It was observed that higher volumetric stream of the permeate was obtained during the process of low-pressure membrane filtration of sewage initially treated in the process of photocatalysis with titanium dioxide (4.6·10-5 m3/m2·s – TiO2 and 4.1·10-5m3/m2·s – ZnO). It was found that the ultrafiltration process in the case of the feed material with TiO2 led to the reduction in COD, TOC and total nitrogen by 78% (370 mg/dm3), 72% (126 mg/dm3) and 40% (80 mg/dm3). Slightly better quality of permeate was obtained when the feed material contained ZnO powder. Degree of retention of the contaminants COD, TOC and total nitrogen were 68% (280 mg/dm3), 66% (143 mg/dm3) and 42% (76 mg/dm3), respectively.
W pracy zaprezentowano wyniki badań jakie otrzymano podczas oczyszczania ścieków mleczarskich w fotoreaktorze membranowy w którym sekwencyjnie skojarzono procesy fotokatalizę z niskociśnieniowym procesem membranowymi. Celem badań było określenie skuteczności degradacji zanieczyszczeń znajdujących się w tego rodzaju wodach odpadowych w samodzielnie prowadzonym procesie fotokatalizy jak również w układzie kojarzącym go z procesem ultrafiltracji. Przeprowadzono szereg eksperymentów w celu ustalenia najkorzystniejszych warunków prowadzenia procesu fotokatalizy tj. dawka zastosowanych fotokatalizatorów (TiO2 i ZnO), czas prowadzenia procesu oraz wartość pH ścieków poddawanych utlenianiu. Dawkę ditlenku tytanu zmieniano w zakresie od 1 do 40 g/dm3 a tlenku cynku od 1 do 6 g/dm3. Na podstawie uzyskanych wyników badań stwierdzono, że wydłużanie czasu naświetlania powyżej 30 minut (TiO2) oraz powyżej 45 min (ZnO) w procesie fotokatalizy nie wpływa na zwiększanie usunięcia zanieczyszczeń z oczyszczanych ścieków mleczarskich. Wykazano również, że zwiększanie stosowanych dawek obu fotokatalizatorów nie skutkuje wzrostu efektywności ich oczyszczania. W przypadku oczyszczania ścieków mleczarskich z TiO2 proces fotokatalizy przebiegał najkorzystniej jego dawce wynoszącej 10 g/dm3. Stopień usunięcia ChZT, OWO i azotu ogólnego wynosił odpowiednio 58% (1670 mg/dm3), 62% (450 mg/dm3) i 56% (128 mg/dm3). Zastąpienie ditlenku tytanu tlenkiem cynku (ZnO – 2g/dm3) w procesie fotokatalizy pozwoliło na uzyskanie wyższych stopni usunięcia zanieczyszczeń oznaczanych jako ChZT, OWO i azotu ogólnego odpowiednio do poziomu 77.8% (870 mg/dm3), 62% (445 mg/dm3) i 52% (139 mg/dm3). Z uwagi na fakt, że oba dawkowano do fotoreaktora w formie zawiesiny to znajdująca się w kolejnym reaktorze membrana była skuteczną barierę dla ich cząstek. Zaobserwowano, że wyższy objętościowy strumień permeatu uzyskano w trakcie prowadzenia procesu niskociśnieniowej filtracji membranowej ścieków wstępnie podczyszczonych w procesie fotokatalizy z ditlenkiem tytanu (4,6·10-5 m3/m2·s – TiO2 i 4,1·10-5 m3/m2·s – ZnO). Stwierdzono że wykorzystany proces ultrafiltracji w przypadku nadawy z TiO2 przyczynił się do obniżenia wartości wskaźników ChZT, OWO i azotu ogólnego odpowiednio o 78% (370 mg/dm3), 72 % (126 mg/dm3) i 40% (80 mg/dm3). Nieznacznie lepszej jakości permeat otrzymano, gdy nadawa zawierała proszek ZnO. Stopień retencji zanieczyszczeń ChZT, OWO i azotu ogólnego wynosił odpowiednio 68% (280 mg/dm3), 66 % (143 mg/dm3) i 42% (76 mg/dm3).
Źródło:
Rocznik Ochrona Środowiska; 2018, Tom 20, cz. 1; 602-615
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies