Tytuł:
Efficiency of the heat pump cooperating with various heat sources in monovalent and bivalent systems
Efektywnosc pompy ciepla wspolpracujacej z dolnymi zrodlami ciepla w systemie mono i biwalentnym
Autorzy:
Kurpaska, S.
Latala, H.
Lapczynska-Kordon, B.
Mudryk, K.
Powiązania:
https://bibliotekanauki.pl/articles/792536.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
heat pump
heat source
heat distribution
monovalent system
bivalent system
compressor heat pump
vertical exchanger
horizontal exchanger
coefficient performance
heating system
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utilisation of low-temperature heat in agriculture using heat pumps - current state and prospects
Wykorzystanie niskotemperaturowego ciepła za pomocą pomp grzejnych w rolnictwie - stan obecny i perspektywy
Autorzy:
Kurpaska, S.
Powiązania:
https://bibliotekanauki.pl/articles/288788.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
pompa ciepła
szklarnia
ciepło odpadowe
heat pump
greenhouse
waste heat
Opis:
The work presents in a synthetic way available results of the research on utilization of heat pumps in agricultural production. Moreover, on the basis of multiannual average values, the researchers calculated potential possibilities for storing waste heat, which may be reused in a typical tomato-growing greenhouse.
W pracy w sposób syntetyczny przedstawiono dostępne wyniki badań wykorzystujących pompę ciepła w produkcji rolniczej. Opierając się na średnich wieloletnich obliczono również potencjalne możliwości magazynowania ciepła odpadowego, możliwego do powtórnego wykorzystania w typowej szklarni w której uprawiane są pomidory.
Źródło:
Inżynieria Rolnicza; 2011, R. 15, nr 7, 7; 65-72
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy efficiency of ground heat exchangers co-operating with a compressor heat pump
Efektywnosc energetyczna wymiennikow gruntowych wspolpracujacych ze sprezarkowa pompa ciepla
Autorzy:
Kurpaska, S.
Latala, H.
Powiązania:
https://bibliotekanauki.pl/articles/793577.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
heat pump
compressor heat pump
heat exchanger
horizontal exchanger
vertical exchanger
coefficient performance
statistical analysis
variance analysis
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy efficiency of ground heat exchangers co-operating with a compressor heat pump
Efektywnosc energetyczna wymiennikow gruntowych wspolpracujacych ze sprezarkowa pompa ciepla
Autorzy:
Kurpaska, S.
Latala, H.
Powiązania:
https://bibliotekanauki.pl/articles/792483.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
compressor heat pump
heat exchanger
horizontal exchanger
vertical exchanger
ground heat exchanger
coefficient performance
statistical analysis
energy efficiency
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 2
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność pracy pompy ciepła współpracującej z wymiennikami gruntowymi
Effectiveness of heat pump working with ground heat exchangers
Autorzy:
Kurpaska, S.
Latała, H.
Powiązania:
https://bibliotekanauki.pl/articles/290666.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
pompa ciepła
efektywność
pionowy wymiennik gruntowy
poziomy wymiennik gruntowy
heat pump
effectiveness
vertical ground heat exchanger
horizontal ground heat exchanger
Opis:
W pracy przedstawiono wyniki badań nad efektywnością pompy ciepła współpracującej z dolnym źródłem ciepła w postaci pionowych i poziomych gruntowych wymienników ciepła. Określono wpływ długości cyklu i długości pracy pompy ciepła w procesie ładowania energią zbiornika buforowego na przebieg średnich wartości współczynnika efektywności. Określono również statystyczną istotność tych zależności.
The work shows results of research on effectiveness of heat pump working with lower heat sources in form of vertical and horizontal ground heat exchangers. The research allowed to determine the influence of cycle length and heat pump work durationin the process of charging the buffer tank with energy on average values of the effectiveness coefficient trajectory. Statistic relevance of these correlations was determined as well.
Źródło:
Inżynieria Rolnicza; 2008, R. 12, nr 6(104), 6(104); 105-112
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metodyczne aspekty analizy zagadnień energetycznych pompy ciepła współpracującej z wymiennikami pionowymi
Methodical aspects of the analysis of energy issues of the heat pump co-operating with vertical heat exchangers
Autorzy:
Kurpaska, S.
Powiązania:
https://bibliotekanauki.pl/articles/287591.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
pompa ciepła
efektywność
pionowe wymienniki gruntowe
heat pump
effectiveness
vertical ground heat exchangers
Opis:
W pracy przedstawiono zmiany efektywności pracy pompy ciepła współpracującej z wymiennikami pionowymi. Na bazie rozważań teoretycznych, wyodrębniono czynniki wpływające na efektywność pompy oraz znaleziono model regresji wielokrotnej opisującej zmiany efektywności w funkcji zmiennych decyzyjnych. Rozważania te, zweryfikowane zostaną podczas badań laboratoryjnych na stanowisku zbudowanym ze sprężarkowej pompy ciepła oraz pionowych wymienników gruntowych o głębokości 100 m.
This work presents the changes of efficiency of operation of the heat pump co-operating with vertical heat exchangers. On the basis of theoretical considerations, factors affecting the efficiency of the pump were distinguished and a model of multiple regression describing changes of efficiency in the function of decision variables was found. These considerations will be verified during laboratory tests at a station built of a compressor heat pump and vertical ground heat exchangers with a depth of 100 m.
Źródło:
Inżynieria Rolnicza; 2010, R. 14, nr 5, 5; 105-112
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wybranych czynników na intensywność wymiany ciepła w ogrzewanym tunelu foliowym
Effect of selected factors on heat exchange intensity in the heated foil tunnel
Autorzy:
Kurpaska, S.
Sporysz, M.
Powiązania:
https://bibliotekanauki.pl/articles/289569.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
tunel foliowy
ekran cieplny
ekran zagrzejnikowy
strumień ciepła
współczynnik wymiany ciepła
foil tunnel
heat screen
thermal screen
heat flux
heat transfer coefficient
Opis:
W pracy zbadano wpływ wyposażenia ogrzewanego tunelu foliowego oraz różnicy temperatury między czynnikiem grzejnym a powietrzem wewnątrz obiektu na intensywność wymiany ciepła. Do analizy wykorzystano dane monitorowane przez system pomiarowy z tunelu zlokalizowanego na Akademii Rolniczej w Krakowie. Uzyskane wyniki badań pozwoliły określić wpływ wyposażenia dodatkowego na intensywność wymiany ciepła, a w konsekwencji na wymaganą powierzchnię grzewczą systemu grzejnego.
The work includes a study of the effect of the outfit of the heated foil tunnel and difference in temperature between heating medium and air inside the object on heat exchange intensity. For the analysis the data monitored by the measuring system in the tunnel located at the Academy of Agriculture in Krakow was used. The results obtained from the analysis allowed to determine the effect of additional equipment on heat exchange intensity, and in consequence on the required heating area of the heating system.
Źródło:
Inżynieria Rolnicza; 2006, R. 10, nr 11(86), 11(86); 261-268
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stanowisko do analizy pracy pomp ciepła wykorzystywanych do ogrzewania tuneli foliowych
Setup for analysing operation of heat pumps used to heat plastic tunnels
Autorzy:
Kurpaska, S.
Sporysz, M.
Powiązania:
https://bibliotekanauki.pl/articles/291602.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
tunel foliowy
pompa ciepła
ogrzewanie
wymiennik ciepła
plastic tunnel
heat pomp
heating
heat exchanger
Opis:
W pracy przedstawiono wyposażenie stanowiska, które będzie służyło do przeanalizowania pracy pomp ciepła wykorzystywanych do ogrzewania tuneli foliowych. Obiekt ten jest zlokalizowany na terenie Wydziału Agroinżynierii Akademii Rolniczej w Krakowie. Obiekt wyposażony jest w zarówno w wymienniki poziome jak i pionowe (dolne źródło ciepła) oraz sprężarkową pompę ciepła.
The paper presents equipment of the stand, which will be used to analyse operation of heat pumps used to heat plastic tunnels. This facility is located at the Faculty of Agricultural Engineering, Agricultural University in Krakow. The system is equipped with horizontal and vertical exchangers (lower heat source), and compressor-type heat pump.
Źródło:
Inżynieria Rolnicza; 2007, R. 11, nr 9 (97), 9 (97); 119-125
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy effects during using the glass with different properties in a heated greenhouse
Autorzy:
Kurpaska, S.
Powiązania:
https://bibliotekanauki.pl/articles/298150.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
greenhouse
optic parameters
glass
heat consumption
Opis:
The paper presents results of calculations conducted on a change of demand for thermal power in a greenhouse covered with standard garden glass and a low-emission glass. Changes of heat demand were also determined. Changes of the amount of fuel (fine coal size grade) as well as changes in the emission of pollutants to the atmosphere were estimated based on calculations. It was determined that covering a greenhouse with low-emission glass has a positive impact on decreasing heat demand.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2014, 17(4); 351-360
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wytyczne konstrukcyjne dla systemu wykorzystującego pompę ciepła na potrzeby ogrzewania obiektu ogrodniczego
Structure guidelines for the system using a heat pump for heating a garden facility
Autorzy:
Kurpaska, S.
Latała, H.
Powiązania:
https://bibliotekanauki.pl/articles/289344.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
pompa ciepła
pionowe gruntowe wymienniki ciepła
obiekt ogrodniczy
heat pump
vertical ground heat exchangers
garden facility
Opis:
W pracy omówiono wielkości, które są wykorzystywane przy projektowaniu obiektów ogrodniczych za pomocą pomp ciepła. Na bazie przeprowadzonej analizy określono zakres zmian efektywnego współczynnika przenikania ciepła przez osłonę obiektu, a także wyznaczono równanie regresji, które w podanym zakresie pozwala na wyliczenie jego wartości. Na bazie wcześniej określonego współczynnika efektywności zainstalowanej pompy grzewczej (COP) określono również wymaganą moc grzewczą pompy ciepła. Moc ta uzależniona została zarówno od warunków środowiskowych (wewnątrz i na zewnątrz obiektu), jak i procentowego pokrycia zapotrzebowania na wymaganą moc cieplną przez pompę grzewczą. Określono również wymaganą liczbę odwiertów wykonanych na głębokość 100 m, w których zainstalowane będą gruntowe, pionowe wymienniki ciepła typu 1xU oraz 2xU. Stwierdzono także, że w wyniku zastosowania w opracowanym nomogramie standardowych zależności, które opisują zagadnienia energetyczne w ogrzewanym obiekcie, opracowane zależności posiadają zarówno walory poznawcze, jak i aplikacyjne. Można je zatem stosować we wszystkich obiektach ogrodniczych, w których zastosowano analizowaną osłonę, a poprzez uogólnienie również w takich obiektach, w których znana jest wartość współczynnika przenikania ciepła oraz powierzchnia obiektu.
Sizes which are used at designing garden facilities with the use of heat pumps were discussed in the paper. Based on the analysis which was carried out, the scope of changes of effective coefficient of heat penetration through the facility cover and regression equation, which in a given scope allows calculation of its value, were determined. Based on the previously determined effectiveness of the installed heat pump (COP) also the required heating power of the heat pump was determined. This power depends on both environmental conditions (inside and outside the facility) as well as the percentage satisfaction of demand for the required heat power by the heat pump. The required number of 100 m boreholes, where ground vertical heat exchangers type 1xU and 2xU will be installed was also determined. Moreover, it was found that as a result of the use of standard relations in the developed nomogram, which describe energy issues in the heated facility, the developed relations have both cognitive as well as application values. Therefore, they may be used in all garden facilities, where the analysed cover was used and by generalization in these objects, where the value of heat penetration coefficient and the area of the facility are known.
Źródło:
Inżynieria Rolnicza; 2013, R. 17, nr 3, t. 1, 3, t. 1; 169-178
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane aspekty współpracy pompy ciepła z gruntowymi wymiennikami ciepła
Selected aspects of co-operation between a heat pump and ground heat exchangers
Autorzy:
Latała, H.
Kurpaska, S.
Sporysz, M.
Powiązania:
https://bibliotekanauki.pl/articles/286855.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
pompa ciepła
efektywność energetyczna
gruntowy pionowy wymiennik ciepła
heat pump
energy efficiency
ground vertical heat exchangers
Opis:
W pracy przedstawiono wyniki badań nad efektywnością sprężarkowej pompy ciepła współpracującej z dolnym źródłem ciepła, który stanowiły dwa odwierty z wymiennikami (typu 1xU oraz 2xU) wykonane na głębokość 100 m każdy. Podczas eksperymentów mierzono niezbędne parametry do wyznaczania efektywności pracy pompy ciepła. System odbioru ciepła stanowiły dwa wymienniki typu ciecz-powietrze, które były zainstalowane w doświadczalnym tunelu foliowym. Określono efektywność energetyczną pracy rozważanego systemu w funkcji zmiennych charakteryzujących pracę pompy ciepła.
The study presents results of the research on efficiency of a compression heat pump, which cooperates with a lower heat source, that is two boreholes with exchangers (type 1xU and 2xU) 100 m deep each. Necessary parameters for determining efficiency of a heat pump operation were measured during the experiments. Two heat-air exchangers, which were mounted in an experimental plastic tunnel constituted a system of heat reception. Operation energy efficiency of the said system was determined in the function of variables, which characterize operation of a heat pump.
Źródło:
Inżynieria Rolnicza; 2011, R. 15, nr 6, 6; 117-124
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza energetyczno-ekologiczna wykorzystania pompy ciepła do ogrzewania tunelu foliowego
Power use and ecological analysis for use of heat pump applied to heat a foil tunnel
Autorzy:
Kurpaska, S.
Latała, H.
Powiązania:
https://bibliotekanauki.pl/articles/287516.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
tunel foliowy
pompa ciepła
emisja
substancja szkodliwa
ciepło
foil tunnel
heat pump
emission
harmful wastes
heat
Opis:
W pracy przedstawiono wyniki badań związanych z efektami energetyczno-ekologicznymi wykorzystania pompy ciepła do ogrzewania tunelu foliowego. Pompa grzewcza pracowała w układzie hybrydowym, tzn. jako dolne źródło ciepła wykorzystano energię zmagazynowaną w zbiorniku cieczowym. W zbiorniku zainstalowano wymiennik stanowiący dolne źródło ciepła sprężarkowej pompy grzewczej. Uzyskane wyniki przeliczono na zmiany emisji substancji szkodliwych emitowanych do atmosfery w wyniku spalania tradycyjnego nośnika ciepła.
The paper presents test results pertaining to power use and ecologic effects for use of heat pump applied to heat a foil tunnel. The heat pump was operated in a hybrid system, i.e. the energy stored in a tank with liquid was used as a lower source of heat; the mentioned tank being equipped with a heat exchanger to be utilized as a lower source of heat for compressor type heat pump. The obtained results were calculated into changes of harmful waste substances flowing to the environment as a result of traditional burning of the heating medium.
Źródło:
Inżynieria Rolnicza; 2007, R. 11, nr 6 (94), 6 (94); 121-127
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatyzacja obliczeń parametrów systemu wykorzystującego cykliczność pracy urządzenia
Automation of computing parameters in a system using equipment operation periodicity
Autorzy:
Sporysz, M.
Kurpaska, S.
Powiązania:
https://bibliotekanauki.pl/articles/286721.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
tunel foliowy
pompa ciepła
automatyzacja obliczeń
gruntowy wymiennik ciepła
foil tunnel
heat pump
computing automation
ground heat exchanger
Opis:
W pracy zaprezentowano narzędzie umożliwiające pełną automatyzację obliczeń parametrów pracy systemu ogrzewania tunelu foliowego za pomocą pompy ciepła. Dane były monitorowane i archiwizowane przez Komputerowy System Pomiarowy zainstalowany w obiekcie doświadczalnym mieszczącym się na terenie Wydziału Agroinżynierii Uniwersytetu Rolniczego w Krakowie. Aplikacja pozwala na wyznaczenie długości cyklu pracy pompy ciepła, tj. czasu ładowania i rozładowywania zbiornika buforowego, ilości ciepła pozyskanej z poziomych i pionowych wymienników ciepła w każdej z zainstalowanych konfiguracji, a także na określenie średniej temperatury wewnątrz tunelu foliowego, temperatury otoczenia, prędkości wiatru i natężenia promieniowania słonecznego.
The paper presents the tool allowing to fully automate computing of work parameters for foil tunnel heating system using heat pump. The data was monitored and archived by the Computer Measuring System installed in an experimental facility at the Faculty of Agricultural Engineering, University of Agriculture in Krakow. The application allows to determine heat pump work cycle duration, that is time required for buffer tank filling and discharge, heat volume acquired from horizontal and vertical heat exchangers in each of the installed configurations, and to specify average temperature inside foil tunnel, ambient temperature, wind velocity and solar radiation intensity.
Źródło:
Inżynieria Rolnicza; 2008, R. 12, nr 10(108), 10(108); 229-236
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatyzacja obliczeń parametrów systemu wykorzystującego cykliczność pracy urządzenia
Automation in computing of parameters for a system using device operation periodicity
Autorzy:
Sporysz, M.
Kurpaska, S.
Powiązania:
https://bibliotekanauki.pl/articles/289733.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
tunel foliowy
pompa ciepła
automatyzacja obliczeń
gruntowy wymiennik ciepła
foil tunnel
heat pump
computing automation
ground heat exchanger
Opis:
W pracy zaprezentowano narzędzie umożliwiające pełną automatyzację obliczeń parametrów pracy systemu ogrzewania tunelu foliowego za pomocą pompy ciepła. Dane były monitorowane i archiwizowane przez Komputerowy System Pomiarowy zainstalowany w obiekcie doświadczalnym mieszczącym się na terenie Wydziału Agroinżynierii Uniwersytetu Rolniczego w Krakowie. Aplikacja pozwala na wyznaczenie długości cyklu pracy pompy ciepła, tj. czasu ładowania i rozładowywania zbiornika buforowego, ilości ciepła pozyskanej z poziomych i pionowych wymienników ciepła w każdej z zainstalowanych konfiguracji, a także na określenie średniej temperatury wewnątrz tunelu foliowego, temperatury otoczenia, prędkości wiatru i natężenia promieniowania słonecznego.
The paper presents a tool allowing to fully automate computing of operation parameters for foil tunnel heating system using heat pump. The data was monitored and archived by Computer Measuring System installed in an experimental facility located at the Faculty of Agroengineering, the University of Agriculture in Krakow. The application allows to determine heat pump work cycle duration, that is thermal store charging and discharging time, heat amount acquired from horizontal and vertical heat exchangers in each of the installed configurations, and to specify average temperature inside the foil tunnel, ambient temperature, wind velocity and solar radiation intensity.
Źródło:
Inżynieria Rolnicza; 2008, R. 12, nr 11(109), 11(109); 233-240
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmienność prędkości przepływu powietrza w akumulatorze ciepła o złożu kamiennym w zależności od konstrukcji układu rozprowadzania powietrza
Variability of the air flow speed in the rock bed heat accumulator depending on the construction of the air circulation system
Autorzy:
Konopacki, P.
Sabat, R.
Hołownicki, R.
Kurpaska, S.
Latała, H.
Powiązania:
https://bibliotekanauki.pl/articles/286537.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
akumulator ciepła ze złożem kamiennym
ciśnienie wylotowe
nieszczelności pneumatyczne
magazynowanie ciepła
rock bed heat accumulator
outlet pressure
air leakage
heat storage
Opis:
Sprawność układu cyrkulacji powietrza w akumulatorze o złożu kamiennym jest jednym z kluczowych czynników warunkujących jego efektywność. Celem pracy było porównanie zmian prędkości przepływu powietrza w eksperymentalnym akumulatorze w zależności od stopnia uszczelnienia samego złoża akumulatora jak i reszty układu cyrkulacji powietrza. Obiektem doświadczalnym były trzy trójsekcyjne akumulatory ciepła, spośród których jeden akumulator był wykonany w trybie uproszczonym, a dwa traktowano jako wzorce instalacji o maksymalnej szczelności. Zmiany prędkości przepływu powietrza mierzonej przy wentylatorze tłoczącym powietrze do akumulatora przyjęto jako miarę efektywności zastosowanych rozwiązań konstrukcyjnych i zastosowanych uszczelnień na kolejnych etapach modyfikacji układu cyrkulacji powietrza. Stwierdzono, że uproszczona konstrukcja akumulatora wykazuje prawie dwukrotnie większy strumień powietrza tłoczonego do akumulatora w porównaniu do akumulatora o maksymalnej szczelności. Efekty wprowadzonych modyfikacji zależą od miejsca ich zastosowania (przed lub za złożem kamiennym) i sekcji akumulatora przez którą jest skierowany przepływ powietrza. Uproszczone uszczelnienia rur przechodzących przez termoizolację oraz połączeń rur w kolektorach rozdzielającym i zbiorczym mogą łącznie spowodować wzrost strumienia powietrza tłoczonego do akumulatora o ok. 28-47%, natomiast uproszczenia w rozłożeniu folii uszczelniającej wokół złoża poszczególnych sekcji akumulatora odpowiadają za ok. 53-72% całkowitego możliwego zakresu zmian strumienia powietrza.
Efficiency of the air circulation system of a rock bed heat accumulator is a key factor for its overall effectiveness. The objective of the paper was to compare the air flows through the complete air circulation system of such accumulator for different solutions of the sealing system. The experimental objects were three 3-sectional rock bed accumulators, of which one was made in a simplified way and then sealing was proceeded in stages, while two others were considered as maximally sealed. The changes of air flow measured near the fan pumping the air into were used as a measure of sealing effectiveness. It has been found that a simplification of sealing in a construction of the rock bed accumulator may result in almost twice higher air flow into the accumulator. The particular effects of simplifications depend on the location (mainly before or after the rock bed) and the location of accumulator’s section (the nearest or the farthest from the fan). The simplifications of sealing of pipe passages through rock bed thermal isolation and pipe connections in air collectors may cause in total about 28-47% of total plausible range of flow changes, while simplifications in arrangement of sealing foil around the rock beds of particular sections of accumulator may result in about 53-72% of total plausible range of flow changes.
Źródło:
Inżynieria Rolnicza; 2013, R. 17, nr 4, t. 1, 4, t. 1; 129-138
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies