Tytuł:
Reliability and quality of ultrasound measurements of fetal heart rate variability
Autorzy:
Jeżewski, J.
Wróbel, J.
Kupka, T.
Matonia, A.
Horoba, K.
Widera, M.
Powiązania:
https://bibliotekanauki.pl/articles/334011.pdf
Data publikacji:
2003
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
zmienność tętna płodu
USG metodą Dopplera
EKG płodu
fetal heart rate variability
Doppler ultrasound method
fetal electrocardiogram
Opis:
This work was aimed at assessment of usability of Doppler ultrasound method for the analysis of fetal heart rate variability at a level of single heart beats. The purpose of this study was to check if today fetal monitors provide the signal of accuracy comparable with an electrocardiography method. The virtual instrumentation software for measurement system and processing of acquired signals was implemented using LABVIEW environment. The results obtained reveal that accuracy of today monitors which use Doppler ultrasound technique is sufficient for visual analysis of the FHR traces. However, for the computerized analysis at a beat-to-beat level, this accuracy is below the acceptable value.
Źródło:
Journal of Medical Informatics & Technologies; 2003, 6; IT21-26
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of signal loss episodes on fetal heart rate variability measures
Autorzy:
Wróbel, J.
Roj, D.
Jeżewski, J.
Horoba, K.
Kupka, T.
Jeżewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/333711.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
fetal heart rate variability
time event series
missing samples
zmienność tętna płodu
zmienność rytmu serca płodu
zdarzenia czasowe
próbka
Opis:
The most important features indicating appropriate fetal development are the measures of instantaneous variability of a fetal heart rate (FHR), describing fluctuations of the beat-to-beat heart intervals. The most popular method for the FHR acquisition is the Doppler ultrasound technique. However, it is very sensitive to various motion artifacts distorting the signal being acquired. The aim of our work was to evaluate the influence of signal loss episodes on the parameters quantitatively describing the instantaneous variability of the FHR. For this purpose we artificially inserted signal loss episodes to the recordings, in different patterns and percentage, in accordance with the real characteristics of the signal loss segments. We particularly would like to answer the question if the signals with significant amount of signal loss can be reliably evaluated by means of instantaneous variability measures, and which of these measures (numerical indices) are more robust to the missing values.
Źródło:
Journal of Medical Informatics & Technologies; 2014, 23; 35-42
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel approach to comparison of the fetal heart rate baseline estimation algorithms
Autorzy:
Jezewski, J.
Horoba, K.
Roj, D.
Wrobel, J.
Kupka, T.
Matonia, A.
Powiązania:
https://bibliotekanauki.pl/articles/332862.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
fetal monitoring
baseline estimation
acceleration
deceleration
monitorowanie płodu
estymacja
przyspieszanie
zwalnianie
Opis:
A number of algorithms for estimating the so called fetal heart rate baseline was proposed so far. However, there is no reference pattern enabling their objective evaluation, and thus no methodology of comparing the competing algorithms still exists. In this paper we propose a method for evaluation of automatically determined baseline in reference to a group of experts, basing on ten separate groups of signals comprising typical patterns observed in the fetal heart rate. For the purpose of quantitative assessment of the estimated baseline a new synthetic inconsistency coefficient is presented. The proposed methodology was applied to evaluate ten well-known algorithms. We believe that the method will be a valuable tool for assessment of the existing algorithms, as well as for developing new ones.
Źródło:
Journal of Medical Informatics & Technologies; 2015, 24; 231-238
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of instantaneous fetal heart rate extracted from abdominal and direct fetal electrocardiograms
Autorzy:
Matonia, A.
Kupka, T.
Jezewski, J.
Momot, A.
Jeżewski, M.
Bernys, M.
Powiązania:
https://bibliotekanauki.pl/articles/333262.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
elektrokardiografia płodu
tętno płodu
fetal monitoring
fetal electrocardiography
fetal heart rate
Opis:
This work is an attempt to assess the reliability of indirect abdominal electrocardiography as an alternative technique of fetal monitoring. As a reference signal we used the simultaneously acquired direct fetal electrocardiogram. Each recording consisted of four signals acquired from maternal abdomen and the reference signal acquired directly from fetal head. The first stage of our study concerned the signal loss episodes. In order to reduce the influence of incorrectly detected R-waves, some certain validation rules were applied. In the second stage, the corresponding intervals determined on basis of both acquisition methods were matched and the accuracy of fetal heart rate measurement was evaluated. Although the accuracy of abdominal electrocardiography turned out to be slightly lower than reported for ultrasound method, it still has some unique features deciding of its prevalence in a certain circumstances.
Źródło:
Journal of Medical Informatics & Technologies; 2012, 19; 101-107
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Coincidence of maternal and fetal QRS complexes in view of fetal heart rate determination
Autorzy:
Kupka, T.
Jeżewski, J.
Matonia, A.
Wróbel, J.
Horoba, K.
Powiązania:
https://bibliotekanauki.pl/articles/333792.pdf
Data publikacji:
2002
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
brzuszne EKG płodu
monitorowanie płodu
tętno płodu
abdominal fetal electrocardiogram
fetal monitoring
fetal heart rate
Opis:
Indirect fetal electrocardiography is a developing diagnostic method in perinatal medicine. Signals of electrical activity being recorded from maternal abdomen surface contain more information than in till now used method of mechanical heart activity measurement based on ultrasound signals. The main problem relies on separation of basic useful component from a signal containing also dominant maternal electrocardiogram and muscles activity artifacts. The algorithms of maternal electrocardiogram suppression via subtraction are commonly used. Although regarding their complexity, these algorithms have limited applicability in systems for long-term monitoring of fetal heart activity. Other solution relies on simple blanking of maternal QRS complexes. However, in case of coincidence of fetal and maternal QRS complexes, this leads to partial loss of information about fetal heart rate variability. For evaluation of how often such coincidence of both complexes takes place, the algorithm has been developed which is described in this paper.
Źródło:
Journal of Medical Informatics & Technologies; 2002, 4; MT49-55
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computerized fetal monitoring based on bioelectric signals from maternal abdomen
Autorzy:
Matonia, A.
Jeżewski, J.
Gacek, A.
Kupka, T.
Horoba, K.
Wróbel, J.
Powiązania:
https://bibliotekanauki.pl/articles/333805.pdf
Data publikacji:
2002
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
elektrokardiografia
tętno płodu
fetal monitoring
fetal abdominal
electrocardiography
fetal heart rate
Opis:
The paper presents an instrumentation set for effective diagnostics of early symptoms of fetal distress in high-risk pregnancy based on bioelectric signals recording. The representative database of records has been established that enabled the complex analysis of signals recorded on a surface of maternal abdomen. As an outcome, the effective algorithms have been developed for processing both the fetal electrocardiogram and the signal of electrical activity of a uterine muscle. This allowed the development of unique diagnostic system based on external biosignal measurement module connected to the standard personal computer. In this system, like in a classical fetal monitor, the fetal heart rate (FHR) signal together with contraction activity signal of uterine muscle and fetal movement become an essential source of information on fetal condition. In addition, there is a possibility for spectral analysis of FHR signal as well as a morphology assessment of fetal ECG signal.
Źródło:
Journal of Medical Informatics & Technologies; 2002, 4; MT37-47
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improving the periodicity measurement in fetal heart activity signal
Autorzy:
Roj, D.
Wróbel, J.
Horoba, K.
Przybyła, T.
Kupka, T.
Powiązania:
https://bibliotekanauki.pl/articles/332933.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
tętno płodu
USG metodą Dopplera
fetal monitoring
fetal heart rate
ultrasound Doppler
Opis:
In this paper we discussed the influence of preliminary processing of the ultrasound Doppler signal on accuracy of the fetal heart rate estimation as well as on reliability of the FHR instantaneous variability assessment. We attempted to develop an optimal processing channel of US Doppler signal in order to measure the periodicity of fetal heart activity with accuracy as close as possible to that ensured by FECG. The FHR values determined from the US signal were compared to the reference data obtained from direct FECG. In a final evaluation we used the parameters describing the FHR variability as the clinically important signal features being the most sensitive to any periodicity inaccuracy. The results proved that an application of proposed algorithms improves the accuracy of interval measurements and FHR instantaneous variability assessment in relation to the new-generation fetal monitors.
Źródło:
Journal of Medical Informatics & Technologies; 2010, 16; 19-26
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of predictive capabilities of quantitative cardiotocographic signal features
Autorzy:
Czabański, R.
Jeżewski, M.
Roj, D.
Szaszkowski, Z.
Kupka, T.
Wróbel, J.
Powiązania:
https://bibliotekanauki.pl/articles/332937.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
tętno płodu
klasyfikacja sygnału
fetal monitoring
fetal heart rate
signal classification
ROC analysis
Opis:
Cardiotocography (CTG) is the main method of assessment of the fetal state during pregnancy and labour used in clinical practice. It is based on quantitative analysis of fetal heart rate, fetal movements and uterine contractions signals. The evaluation of the CTG signals can be made using criteria recommended by International Federation of Obstetrics and Gynecology. Nevertheless, the diagnosis verification is possible only after the delivery on the basis of newborn assessment. In the proposed work we evaluated the capacity of quantitative analysis of CTG traces in predicting fetal outcome. The relationship between CTG signal features and attributes of fetal outcome was assessed on the basis of ROC curves analysis. The obtained results indicate the adequate predictive capabilities of the selected CTG features especially for fetal outcome assessed with Apgar score and suggest the necessity of applying the criteria for the CTG traces evaluation that are related to the gestational age. Our study also shows the value of the CTG monitoring as a screening procedure providing appropriate confirmation of fetal wellbeing.
Źródło:
Journal of Medical Informatics & Technologies; 2010, 16; 11-17
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automated detection of fetal movements in Doppler ultrasound signals versus maternal perception
Autorzy:
Wróbel, J.
Kupka, T.
Horoba, K.
Matonia, A.
Roj, D.
Jeżewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/333732.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
fetal movement activity
Doppler ultrasound signal
fetal heart rate
aktywność ruchowa płodu
sygnał USG Dopplera
tętno płodu
Opis:
Analysis of movement activity is important since it enables detection of nonreactive fetal heart rate recordings. The aim of the study was to develop an algorithm for automated detection of the fetal movement activity (actogram), based on analysis of the Doppler ultrasound signal, and to evaluate a reliability of the actogram as a source of information about the fetal movements. Bandpass filtering (20-80 Hz) was used to separate the actogram signal describing the fetal movement activity. Simultaneously there were recorded the markers of fetal movements perceived by mother, being the reference information. For the determination of the binary actogram, the authors proposed an algorithm in which the classification threshold was estimated at the beginning of each recording and was adaptively modified during its duration. The algorithm ensured detection of up to 89% of movement episodes corresponding to movements perceived by mother. At the same time almost as high number of episodes not related to the reference information was recognized. Obtained results revealed that the automated analysis of fetal movements is characterized by much higher sensitivity of movement episode detection compared to the maternal perception.
Źródło:
Journal of Medical Informatics & Technologies; 2014, 23; 43-50
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of fetal movements based on actogram signal analysis
Autorzy:
Kupka, T.
Matonia, A.
Wróbel, J.
Horoba, K.
Jeżewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/333340.pdf
Data publikacji:
2004
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
USG Dopplera
aktogram
aktywność ruchowa płodu
tętno płodu
Doppler ultrasound
actogram
fetal movement activity
fetal heart rate
Opis:
At present, biophysical fetal monitoring relies mainly on evaluation of a fetal heart rate (FHR). Absence of the FHR variability indicates central nervous system depression associated with hypoxia. The analysis of fetal heart rate segments identified with the aid of information on fetal movement activity provides much better results than analysis of the whole signal. Automatic recording of the fetal movement activity in a form of actogram signal provided by new models of fetal monitors becomes very common. For evaluation of information content of the actogram signal, the measurement instrumentation has been developed. The examined group comprised 20 patients and the total time of recording was 10 hours. Correlation between movements observed by clinical experts on ultrasonographic image and actogram trace recorded by fetal monitor was analysed. Although for head, arms, legs and trunk movements just visual analysis let observe their correlation with actogram signal, but in case of breathing movement no correlation was noted. Depending on movement type the detection efficiency was in range from 54 % to 80 %.
Źródło:
Journal of Medical Informatics & Technologies; 2004, 8; MM119-128
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reconstruction of FHR series recorded via ultrasound - method validation using abdominal fetal electrocardiography
Autorzy:
Kupka, T.
Horoba, K.
Roj, D.
Matonia, A.
Czabanski, R.
Jezewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/333726.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
fetal heart rate variability
time event series
sampled signal
duplicated sample
zmienność rytmu serca płodu
sygnał próbny
powielona próbka
Opis:
Analysis of variability of the fetal heart rate (FHR) is very important for fetal wellbeing assessment. The beat-to-beat variability is described quantitatively by the indices originated from invasive fetal electrocardiography which provides the FHR signal in a form of time event series. Nowadays, monitoring instrumentation is based on Doppler ultrasound technology. The fetal monitors provide the output signal in a form of evenly spaced measurements. The goal of this work is to present a new method for the FHR signal processing, which enables extraction of time series of consecutive heartbeat intervals from the evenly repeated values. The proposed correction algorithm enables recognition and removal of the duplicated measurements. Reliable evaluation of the algorithm requires the reference event series, thus the FHR signals were obtained from abdominal fetal electrocardiograms to be used in this research study.
Źródło:
Journal of Medical Informatics & Technologies; 2013, 22; 135-141
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Combined analysis of fetal electrocardiogram and systolic time intervals
Autorzy:
Matonia, A.
Jeżewski, J.
Kupka, T.
Horoba, K.
Wróbel, J.
Widera, M.
Powiązania:
https://bibliotekanauki.pl/articles/334019.pdf
Data publikacji:
2003
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
wybrany termin cyklu sercowego
EKG płodu
tętno płodu
fetal monitoring
cardiac cycle timing
fetal electrocardiography
fetal heart rate
Opis:
Cardiotocography as a simultaneous recording of fetal heart rate (FHR) and uterine contraction activity is a basic method of evaluation of fetal condition. Correct variability of the fetal heart rate is an indirect sign of adequate oxygenation of a fetus. Unfortunately, the reverse case is not always true, signs suggesting pathological changes can also appear in recording when the fetal is not at risk. The cardiotocography shall then be recognized as a more screening than diagnostic method. It will be interesting to develop a non-invasive method being complementary to routine cardiotocography. This method should allow the adequate prediction of a bad neonatal outcome when the test is abnormal. The paper shows the system that makes possible cardiotocograms analysis in parallel with the assessment of additional parameters determined from comparison of mechanical and electrical fetal heart activity signals. The studies are aimed at development of set of parameters that are high correlated with clinical outcome.
Źródło:
Journal of Medical Informatics & Technologies; 2003, 6; IT27-34
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-12 z 12

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies