Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Bohdziewicz, J." wg kryterium: Autor


Tytuł:
Influence of water matrix on the retention of pharmaceuticals by high-pressure membrane filtration
Wpływ matrycy wodnej na retencję farmaceutyków w wysokociśnieniowej filtracji membranowej
Autorzy:
Kudlek, E.
Bohdziewicz, J.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/388943.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
diclofenac
ibuprofen
carbamazepine
nanofiltration
diklofenak
karbamazepina
nanofiltracja
Opis:
High-pressure membrane processes, including nanofiltration and reverse osmosis, allow for the removal of a wide range of organic micropollutants (including pharmaceutical compounds) from water streams. Those processes also may be an effective method for in-depth treatment of water containing pharmaceutical compounds. The paper presents a comparison of retention of selected pharmaceuticals from the group of non-steroidal and anti-inflammatory drugs, ie ibuprofen and diclofenac and psychotropic drugs – carbamazepine, present in various aqueous matrices in the nanofiltration process. Deionized water based solutions as well as model and real wastewater effluents after biological treatment processes were subjected to the filtration process. The nanofiltration process was carried out in a cross-flow tubular membrane filtration system. Three polyamide membranes AFC30, AFC40 and AFC80 from PCI Membrane System Inc were used. It has been found, that the retention of pharmaceutical compounds increased with the membrane filtration time, regardless of the composition of the treated aqueous matrix. Moreover, the presence of inorganic compounds and high-molecular organic substances had a positive effect on the membrane separation process of micropollutants.
Wysokociśnieniowe procesy membranowe, do których zaliczamy nanofiltrację i odwróconą osmozę, pozwalają na oczyszczenie strumieni wodnych z szerokiej gamy mikrozanieczyszczeń organicznych. Mogą znaleźć również zastosowanie w doczyszczaniu wód pod kątem eliminacji związków farmaceutycznych. W pracy przedstawiono porównanie stopnia retencji wybranych farmaceutyków z grupy niesteroidowych leków przeciwbólowych i przeciwzapalnych, tj. ibuprofen i diklofenak oraz leków psychotropowych – karbamazepina, obecnych w różnych matrycach wodnych w procesie nanofiltracji. Oczyszczaniu poddano roztwory sporządzone na bazie wody zdejonizowanej oraz modelowy i rzeczywisty odpływ po biologicznym oczyszczaniu ścieków. Proces nanofiltracji prowadzono w układzie filtracji krzyżowej przy zastosowaniu rurowego modułu membranowego. Oceniono efektywność procesu przy wykorzystaniu trzech poliamidowych membrana, tj. AFC30, AFC40 i AFC80 firmy PCI Membrane System Inc. Określono, że wraz z czasem filtracji membranowej wzrasta stopień retencji badanych związków farmaceutycznych niezależnie od składu oczyszczanej matrycy wodnej. Ponadto stwierdzono, że obecność w roztworze związków nieorganicznych oraz wysokocząsteczkowych substancji organicznych wpływa korzystnie na proces membranowej separacji mikrozanieczyszczeń.
Źródło:
Ecological Chemistry and Engineering. A; 2015, 22, 4; 469-479
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of selected nonsteroidal anti-inflammatory drugs in the aquatic environment
Oznaczanie wybranych niesteroidowych leków przeciwbólowych i przeciwzapalnych w środowisku wodnym
Autorzy:
Kudlek, E.
Bohdziewicz, J.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/953514.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
diclofenac
ibuprofen
SPE
HPLC-UV
GC-MS (EI)
diklofenak
ekstrakcja SPE
Opis:
The presence of pharmaceutical compounds in the aquatic environment requires the development of an effective monitoring method. The paper presents the developed procedure of determination of pharmaceutical compounds selected from the group of nonsteroidal anti-inflammatory drugs – ibuprofen and diclofenac. To isolate selected compounds from the tested water the solid phase extraction (SPE) was employed. The quantitative and qualitative analysis was carried out by high performance liquid chromatography HPLC (UV) as well as gas chromatography coupled with mass spectrometry with electron ionization GC-MS (EI). Described analytical procedures allows to separate and quantificat pharmaceutical mixtures with a satisfactory reproducibility and accuracy. The values of the recovery degree confer the possibility of the complete quantitative control of tested pharmaceuticals in water samples. The described method can be used to control the analytical processes of natural water purification and wastewater treatment from pharmaceutical compounds.
Obecność związków farmaceutycznych w środowisku wodnym wymusza opracowanie skutecznej metody ich monitoringu. W pracy przedstawiono opracowany sposób oznaczenia wybranych związków farmaceutycznych z grupy niesteroidowych leków przeciwbólowych i przeciwzapalnych, tj. ibuprofenu i diklofenaku. Do wydzielenia analitów zastosowano ekstrakcję do fazy stałej (SPE), a do analizy jakościowo-ilościową wysokosprawną chromatografię cieczową HPLC (UV) oraz chromatografię gazową sprzężoną z detektorem masowym (GC-MS). Opracowana procedura analityczna umożliwia rozdział i oznaczenie ilościowe mieszaniny związków farmaceutycznych z zadowalającą powtarzalnością i dokładności ą. Wyznaczone wartości stopni odzysku dają możliwość pełnej kontroli ilościowego oznaczenia badanych farmaceutyków w próbkach wodnych. Powyższa metoda może znaleźć zastosowanie do kontroli analitycznej przebiegu procesów uzdatniania wód naturalnych i doczyszczania ścieków pod kątem eliminacji związków farmaceutycznych.
Źródło:
Ecological Chemistry and Engineering. A; 2014, 21, 2; 177-187
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ matrycy wodnej na retencję związków farmaceutycznych w procesie nanofiltracji
Influence of water matrix on the retention of pharmaceutical compounds by nanofiltration
Autorzy:
Kudlek, E.
Dudziak, M.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/125822.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
diklofenak
ibuprofen
karbamazepina
nanofiltracja
diclofenac
carbamazepine
nanofiltration
Opis:
Wysokociśnieniowe procesy membranowe, do których zalicza się nanofiltrację i odwróconą osmozę, pozwalają na oczyszczenie strumieni wodnych z szerokiej gamy mikrozanieczyszczeń organicznych. Mogą znaleźć również zastosowanie w doczyszczaniu wód pod kątem eliminacji związków farmaceutycznych. W pracy przedstawiono porównanie stopnia retencji wybranych farmaceutyków z grupy niesteroidowych leków przeciwbólowych i przeciwzapalnych, tj. ibuprofenu i diklofenaku oraz leków psychotropowych - karbamazepina, obecnych w różnych matrycach wodnych w procesie nanofiltracji. Oczyszczaniu poddano roztwory sporządzone na bazie wody zdejonizowanej oraz modelowy i rzeczywisty odpływ po biologicznym oczyszczaniu ścieków. Proces nanofiltracji prowadzono w układzie filtracji krzyżowej przy zastosowaniu rurowego modułu membranowego wyposażonego w poliamidową membranę AFC80 firmy PCI Membrane System Inc. Określono, że wraz z czasem filtracji membranowej wzrasta stopień retencji badanych związków farmaceutycznych niezależnie od składu oczyszczanej matrycy wodnej. Ponadto stwierdzono, że obecność w roztworze związków nieorganicznych oraz wysokocząsteczkowych substancji organicznych wpływa korzystnie na proces membranowej separacji mikrozanieczyszczeń.
High-pressure membrane processes, including nanofiltration and reverse osmosis, allow for the removal of a wide range of organic micropollutants (including pharmaceutical compounds) from water streams. Those processes also may be an effective method for in-depth treatment of water containing pharmaceutical compounds. The paper presents a comparison of retention of selected pharmaceuticals from the group of non-steroidal and antiinflammatory drugs, i.e., ibuprofen and diclofenac and psychotropic drugs - carbamazepine, present in various aqueous matrices in the nanofiltration process. Deionized water based solutions as well as model and real wastewater effluents after biological treatment processes were subjected to the filtration process. The nanofiltration process was carried out in a cross-flow tubular membrane filtration system equipped with the AFC80 polyamide membrane from PCI Membrane System Inc. It has been found, that the retention of pharmaceutical compounds increased with the membrane filtration time, regardless of the composition of the treated aqueous matrix. Moreover, the presence of inorganic compounds and high-molecular organic substances had a positive effect on the membrane separation process of micropollutants.
Źródło:
Proceedings of ECOpole; 2016, 10, 2; 677-684
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elimination of pharmaceutical compounds from municipal wastewater by photocatalysis, microfiltration and nanofiltration
Autorzy:
Kudlek, E.
Bohdziewicz, J.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/106011.pdf
Data publikacji:
2015
Wydawca:
Centrum Badań i Innowacji Pro-Akademia
Tematy:
pharmaceuticals
sequential system
photocatalysis
microfiltration
nanofiltration
farmaceutyki
układ sekwencyjny
fotokataliza
mikrofiltracja
nanofiltracja
Opis:
The aim of the study was to develop an innovative method for the removal of selected pharmaceuticals from biologically treated municipal wastewater. The photocatalytic oxidation in the presence of TiO2 was carried out in a reactor irradiated with a UV lamp (power 150 W) and two-stage membrane filtration was also applied. In the first stage the catalyst particles were separated using a microfiltration membrane. In the second stage the wastewater was polished in a semi-industrial installation equipped with a flow-through tubular membrane module with a filter surface area of 240 cm2. The system combining photocatalysis and membrane filtration allowed for complete elimination of the pharmaceuticals.
Źródło:
Acta Innovations; 2015, 16; 12-19
2300-5599
Pojawia się w:
Acta Innovations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany toksyczności wody zawierającej wybrane farmaceutyki w procesie utleniania fotokatalitycznego
Toxicity changes of water containing selected pharmaceuticals during the photocatalytic oxidation process
Autorzy:
Bohdziewicz, J.
Kudlek, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/127378.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
mikrozanieczyszczenia
oczyszczanie strumieni wodnych
toksyczność
test MICROTOX
uboczne produkty utleniania
micropollutants
treatment of water streams
toxicity
MICROTOX test
oxidation by-products
Opis:
Spośród metod badań jakościowych wody i ścieków wymienia się obecnie test MICROTOX®, w którym w charakterze bioindykatora są stosowane bakterie luminescencyjne Vibrio fischeri. W pracy przedstawiono wyniki analizy toksyczności roztworów wodnych, zawierających wybrane farmaceutyki z grupy niesteroidowych leków przeciwzapalnych (diklofenak, ibuprofen) przed i po procesie utleniania fotokatalitycznego. Badano zarówno wpływ stężenia leku, jak i czasu utleniania na zmianę toksyczności próbek wodnych. Stopień usunięcia badanych farmaceutyków został oceniony z użyciem HPLC. Określono, że zastosowanie testu MICROTOX® może być przydatne w ocenie ryzyka wynikającego z możliwości powstawania produktów ubocznych procesu utleniania badanych związków farmaceutycznych.
Nowadays one of the water and wastewater quality test methods is the MICROTOX® test, in which luminescent bacteria Vibrio fisheri are employed as a bioindicator. The study presents the results of the toxicity tests of water solutions containing selected pharmaceuticals from the group of non-steroidal anti-inflammatory drugs (diclofenac, ibuprofen) before and after the photocatalytic oxidation process. The influence of the drug concentration and the oxidation time on the change of the water samples toxicity was examined. The removal degree of chosen pharmaceuticals has been evaluated by HPLC. The obtained results indicate that the MICROTOX® test is thought to be useful in assessment of the risk resulting from the possible formation of by-products of the oxidation of selected pharmaceutical micropollutants.
Źródło:
Proceedings of ECOpole; 2014, 8, 1; 135-140
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analytical control of diclofenac removal in the photocatalytic oxidation process
Kontrola analityczna usuwania diklofenaku w procesie fotokatalitycznego utleniania
Autorzy:
Bohdziewicz, J.
Kudlek, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/395955.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
diclofenac
photocatalysis
absorbance in UV
organic carbon
stężenie farmaceutyków w ściekach
usuwanie diklofenaku
fotokataliza
utlenianie
absorbancja w UV
węgiel organiczny
Opis:
Continuously increasing pharmaceuticals consumption contributes to the increase of their concentration in the aqueous environment, which is at a level of a few ng/dm3 to several μg/dm3. A numerous group of pharmaceuticals occurring in surface waters are non-steroidal painkillers and anti-inflammatory drugs, which include diclofenac. The paper presents the possibility of the analytical control of diclofenac photocatalytic oxidation process in the aquatic environment. To examine the effectiveness of the process various instrumental methods including HPLC analysis preceded with solid phase extraction SPE, measurements of UV absorbance and total organic carbon were used.
Stale rosnąca konsumpcja farmaceutyków przyczynia się do zwiększenia ich stężenia w środowisku wodnym, które kształtuje się na poziomie od kilku ng/dm3 do kilku μg/dm3 3. Liczną grupę wśród farmaceutyków występujących w wodach powierzchniowych stanowią niesteroidowe leki przeciwbólowe i przeciwzapalne, do których należy m.in. diklofenak. W pracy przedstawiono możliwości kontroli analitycznej procesu fotokatalitycznego utleniania diklofenaku w środowisku wodnym. Do badania skuteczności procesu zastosowano różne metody instrumentalne, w tym analizę HPLC poprzedzoną ekstrakcją do fazy stałej oraz pomiar przewodności właściwej, absorbancji w UV (λ=276 nm) i ogólnego węgla organicznego. W celu określenia obniżenia stężenia usuwanego związku przydatna okazała się analiza chromatograficzna, z którą w dobrym stopniu korespondowały wyniki pomiarów absorbancji w UV. Dowiedziono, że pomiar chromatograficzny charakteryzuje się większą czułością niż pomiar absorbancji wody. Na podstawie pomiarów ogólnego węgla organicznego określono, że degradacja usuwanego związku nie jest kompletna i powstają produkty uboczne tego procesu.
Źródło:
Civil and Environmental Engineering Reports; 2013, 11; 23-30
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinetyka fotokatalitycznego rozkładu wybranych mikrozanieczyszczeń organicznych w środowisku wodnym
Kinetics of the photocatalytic degradation of selected organic micropollutants in the water environment
Autorzy:
Kudlek, E.
Dudziak, M.
Kamińska, G.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/399772.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
fotokataliza
mikrozanieczyszczenia organiczne
kinetyka procesu
photocatalysis
organic micropollutants
process kinetics
Opis:
W pracy przedstawiono ocenę stopnia usunięcia wybranych wielopierścieniowych węglowodorów aromatycznych (antracen, benzo(a)piren), ksenoestrogenów (oktylofenol, pentachlorofenol) oraz związków farmaceutycznych (diklofenak) w procesie heterogenicznej fotokatalizy z ich roztworów wodnych sporządzonych na bazie wody zdejonizowanej. Jako fotokatalizator procesu zastosowano ditlenek tytanu w dawce 100 mg/dm3. Kinetykę procesu wyznaczono w oparciu o równanie Langmuira- Hinsherlwooda, przy założeniu pseudo-pierwszorzędowego przebiegu reakcji rozkładu mikrozanieczyszczeń. Ponadto wykonano analizę toksykologiczną próbek roztworów wodnych badanych związków po procesie ich naświetlania przy użyciu testu Microtox®. Stwierdzono, że wraz ze wzrostem czasu prowadzenia procesu obniżało się stężenie badanych mikrozanieczyszczeń, a stopień ich usunięcia po 60 minutach przekraczał 90%. Analiza kinetyki procesu wykazała, że utlenianie związków zachodziło najintensywniej w pierwszej fazie prowadzenia procesu naświetlania tj. do 10 minuty. Wykonana ocena toksykologiczna potwierdziła niecałkowity rozkład zanieczyszczeń i generowanie ubocznych produktów wpływających na wzrost toksyczności oczyszczanych roztworów wodnych.
The paper presents an assessment of the removal degree of selected polycyclic aromatic hydrocarbons (anthracene, benzo(a)pyrene), xenoestrogens (octylphenol, pentachlorophenol) and pharmaceutical compounds (diclofenac) in the process of heterogeneous photocatalysis of their water solutions, which were prepared on the base of deionized water. Titanium dioxide at a dose of 100 mg/dm3 was used as a photocatalyst of the process. The kinetics of the process was determined based on the Langmuir-Hinsherlwood equation, assuming the pseudo-first-order reaction of micropollutants decomposition. Furthermore a toxicological analysis of water samples of test compounds was performed by the use of the Microtox® test. It has been found that the micropollutant concentrations decreased with the increase of process time and their removal degree after 60 minutes exceeds 90%. The analysis of the proces kinetic showed that the oxidation of the compounds occurred with the greatest intensity in the first stage of the process up to 10 min. The preformed toxicological assessment confirmed the incomplete decomposition of pollutants and the generation of by-products, which contribute to the increase of the toxicity of treated water solutions.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 2; 75-82
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie mikrozanieczyszczeń w laboratoryjnym wielofunkcyjnym reaktorze membranowym
Removal of micropollutants in the laboratory multifunctional membrane reactor
Autorzy:
Kudlek, E.
Dudziak, M.
Bohdziewicz, J.
Kamińska, G.
Powiązania:
https://bibliotekanauki.pl/articles/126021.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
reaktor membranowy
promieniowanie UV
ścieki oczyszczone
mikrozanieczyszczenia
membrane reactor
UV irradiation
wastewater effluent
micropollutants
Opis:
Hybrydowe układy oczyszczania ścieków oparte o zaawansowane procesy utleniania i techniki membranowe stanowią alternatywę nie tylko do konwencjonalnych układów oczyszczania strumieni wodnych, ale również do układów sekwencyjnych bazujących na pogłębionych procesach oczyszczania. W pracy przedstawiono ocenę stopnia usunięcia mikrozanieczyszczeń organicznych z grupy wielopierścieniowych węglowodorów aromatycznych - antracenu i bezno(a)pirenu - oraz domieszek przemysłowych, tj. pentachlorofenolu i oktylofenolu, jak również związków farmaceutycznych - diklofenaku z oczyszczonych ścieków bytowo-gospodarczych na poszczególnych etapach cyklu pracy fotokatalitycznego laboratoryjnego wielofunkcyjnego reaktora membranowego. Proces oczyszczania realizowano bez i z dodatkiem katalizatora w postaci komercyjnego ditlenku tytanu. Dobrane parametry pracy reaktora umożliwiły ponad 73% usunięcie badanych mikrozanieczyszczeń w procesie prowadzonym bez dodatku katalizatora. Wprowadzenie półprzewodnika do oczyszczanego roztworu wodnego pozwoliło na kompletne usunięcie pentachlorofenolu, oktylofenolu, bezno(a)pirenu oraz diklofenaku. Wykazano, że zastosowana membrana ultrafiltracyjna pełniła nie tylko rolę przegrody separującej cząsteczki stosowanego katalizatora, ale również pozwalała na zatrzymanie mikrozanieczyszczeń, których współczynniki retencji mieściły się w zakresie od 9% dla pentachlorofenolu do 98% dla bezno(a)pirenu.
Hybrid wastewater treatment systems based on advanced oxidation processes and membrane techniques are an alternative both to conventional water treatment systems and sequential systems based on deep-treatment processes. The paper presents the estimation of the removal rate of organic micropollutants from wastewater effluent at various phases of the photocatalytic laboratory multifunctional membrane reactor. The tested compounds belong to the group of polycyclic aromatic hydrocarbons - anthracene and benzo(a)pyrene, industrial additives i.e. pentachlorophenol and octylphenol, as well as pharmaceuticals - diclofenac. The treatment process was carried out without or with the addition of a catalyst in the form of commercial titanium dioxide. Reactor’s selected operating parameters allowed to remove over 73% of the tested micropollutants in the process carried out without catalyst. The addition of the semiconductor to the treated water solution allowed to remove completely pentachlorophenol, octylphenol, benzo(a)pyrene and diclofenac. It has been shown that the ultrafiltration membrane acts not only as a separation barrier of the catalyst, but also allows for the retention of micropollutants, which removal rate ranged from 9% for pentachlorophenol to 98% for benzo(a)pyrene.
Źródło:
Proceedings of ECOpole; 2017, 11, 2; 525-532
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie WWA i ich zachowanie w trakcie mechaniczno-biologicznego oczyszczania ścieków
Removal and fate of PAHs during mechanical-biological wastewater treatment
Autorzy:
Kamińska, G.
Kudlek, E.
Dudziak, M.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/126459.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
WWA
monitoring
oczyszczanie ścieków
PAHs
wastewater treatment
micropollutants
Opis:
Przedstawiono wyniki monitoringu wielopierścieniowych węglowodorów aromatycznych w ściekach surowych, wstępnie oczyszczonych na stopniu mechanicznym oraz odprowadzanych do środowiska. Obiektem badań były 3 komunalne oczyszczalnie ścieków zlokalizowane w województwie śląskim. Procedura oznaczenia związków obejmowała wydzielenie badanych substancji z próbek ścieków za pomocą ekstrakcji do fazy stałej, a następnie analizę chromatograficzną GC-MS. Przeprowadzone badania pozwoliły również ocenić skuteczność ich usuwania na poszczególnych stopniach oczyszczenia. Spośród 16 badanych WWA największe stężenie w ściekach surowych odnotowano dla pirenu. Tendencja ta została zaobserwowana dla wszystkich trzech badanych oczyszczalni. Stwierdzono również, że w ściekach z oczyszczalni o największej przepustowości zawartość mikrozanieczyszczeń była około 2 razy większa w stosunku do ścieków pobieranych z mniejszych obiektów. Skuteczność usuwania badanych związków podczas mechaniczno-biologicznego oczyszczania ścieków kształtowała się w zakresie od 65 do 97%.
This study presents results of the monitoring of 16 polycyclic aromatic hydrocarbons in raw, primary treated and secondary treated wastewater from 3 WWTPs located in Silesia. The assay procedure of the compounds included the separation of substances from sewage samples by solid phase extraction and chromatographic analysis with GC-MS. Based on calculated concentration of given PAHs in wastewater we determined their removal degree at various stages of treatment. Among 16 studied PAHs the highest concentration in raw sewage was reported for pyrene. This trend was observed for all three studied WWTPs. It was also found that wastewater from the WWTPs with the highest capacity was about 2 times higher in relation to the wastewater collected from smaller objects. The removal efficiency of the studied compounds during mechanical - biological treatment was in the range of 65 to 97%.
Źródło:
Proceedings of ECOpole; 2016, 10, 2; 653-660
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania efektu toksykologicznego fotokatalizatorów
Study of toxicological effect of photocatalysts
Autorzy:
Kudlek, E.
Dudziak, M.
Bohdziewicz, J.
Kamińska, G.
Powiązania:
https://bibliotekanauki.pl/articles/126720.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
TiO2
ZnO
promieniowanie UV
toksyczność roztworu
UV irradiation
toxicity of solution
Opis:
Efektywność rozkładu zanieczyszczeń organicznych w procesie fotokatalizy zależy od szeregu czynników, wśród których decydującą rolę odgrywają zarówno, dobór rodzaju, jak i dawki fotokatalizatora. Do najczęściej opisywanych w literaturze półprzewodników stosowanych w procesach oczyszczania strumieni wodnych zalicza się tlenek tytanu(IV) i tlenek cynku. W pracy przedstawiono zmiany toksyczności wodnych mieszanin fotokatalizatorów bez i w trakcie ich naświetlania promieniami UV o długości fali przekraczającej 300 nm. Badania prowadzono z użyciem czterech półprzewodników, tj. TiO2 jako mieszaniny anatazu i rutylu, TiO2 w postaci czystego anatazu, ZnO oraz ZnO farmaceutycznego w dawce 25, 50, 100 i 200 mg/dm3. Efekt toksyczny oceniono z użyciem biotestu Microtox®. Wykazano, że wraz ze wzrostem czasu napromieniowania mieszaniny ZnO oraz ZnO farmaceutycznego wzrasta odpowiedź toksykologiczna organizmów testowych. Świadczy to o braku stabilności fotochemicznej obu tych półprzewodników oraz dyskwalifikuje ich użycie w przypadku oczyszczania strumieni wodnych odprowadzanych do środowiska naturalnego. Zmiany efektu toksykologicznego nie obserwowano w przypadku mieszanin wodnych z półprzewodnikami, które nie były naświetlane promieniami UV. Również naświetlanie mieszanin zawierających TiO2 bez względu na formę nie wpłynęło na zmianę ich toksyczności.
The efficiency of decomposition of organic pollutants during photocatalytic oxidation process depends on several factors, among which the type and dose of photocatalyst plays a significant role. According to literature, the most commonly used semiconductors in processes of water streams treatment are titanium dioxide and zinc oxide. The paper presents the change in toxicity of aqueous mixtures of photocatalysts unirradiated and irradiated with UV light with wavelength greater than 300 nm. Studies were carried out by the use of four semiconductor i.e. TiO2 as a mixture of anatase and rutile, TiO2 as a pure form of anatase, ZnO and pharmaceutical ZnO at a dose of 25, 50, 100 and 200 mg/dm3. Toxic effects were evaluated using the Microtox® bioassay. It has been demonstrated that the toxic response of the test organisms increases with the increase of the irradiation time of mixtures containing ZnO and ZnO pharmaceutical. That fact indicates a lack of photochemical stability of both semiconductors and disqualifies their use during the treatment of water streams which will be discharged into the environment. Changes in toxicological effects were not observed for semiconductors water mixtures, which were not irradiated with UV light. Also, the UV exposure of mixtures containing TiO2 did not affect any change of their toxicity.
Źródło:
Proceedings of ECOpole; 2017, 11, 1; 201-209
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności usuwania wybranych substancji aktywnych biologicznie w procesie nanofiltracji
Effectivness of removal of selected biologically active micropollutants in nanofiltration
Autorzy:
Kamińska, G.
Dudziak, M.
Bohdziewicz, J.
Kudlek, E.
Powiązania:
https://bibliotekanauki.pl/articles/126779.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
substancje aktywne biologicznie
nanofiltracja
nanofiltration
biologically active compounds
Opis:
W pracy podjęto badania nad oceną skuteczności usuwania pięciu różnych związków należących do grupy substancji aktywnych biologicznie, tj. benzo(a)pirenu (BaP), antracenu (ANT), diklofenaku (DCL), pentachlorofenolu (PCP) i oktylofenolu (OP), w procesie nanofiltracji. Przedmiotem badań były modelowe roztwory tych substancji o stężeniu 500 μg/dm3, wykonane na bazie wody zdejonizowanej. Uzyskane wyniki badań porównano pod kątem skuteczności usuwania wybranych związków z syntetycznych i rzeczywistych odpływów z komunalnej oczyszczalni ścieków. Wykazano, że na skuteczność procesu nanofiltracji istotny wpływ ma rodzaj membrany nanofiltracyjnej, właściwości fizykochemiczne usuwanych związków, jak również rodzaj matrycy środowiskowej poddawanej oczyszczaniu. Najwyższą efektywność usuwania zaobserwowano dla benzopirenu w trakcie nanofiltracji wody zdejonizowanej. Współczynniki retencji wynosiły wówczas od 99,82 do 99,94%, co oznacza praktycznie jego całkowite usunięcie. Z kolei dla pozostałych związków z wyjątkiem oktylofenolu zaobserwowano odwrotną tendencję, wyższe współczynniki retencji uzyskano, gdy filtrowanym medium były ścieki syntetyczne lub rzeczywiste. Przeprowadzone badania udokumentowały złożony mechanizm separacji małocząsteczkowych mikrozanieczyszczeń organicznych w procesie nanofiltracji wynikający m.in. z oddziaływań międzycząsteczkowych, efektu sitowego, jak również adsorpcji.
This study addressed the removal efficiency of five different compounds classified as biologically active compounds ie benzo(a)pyrene (BaP), anthracene (ANT), diclofenac (DCL), pentachlorophenol (PCP), octylphenol (OP) in nanofiltration. They were removed from deionized water solution of 500 μg/dm3 and comparatively from synthetic and municipal effluent. It was found that the efficiency of the nanofiltration depends significantly both on type of membrane and the environmental matrix and physic-chemical properties of the compounds present in the treated waste feed. The highest retention was observed for benzo(a)pyrene removed from deionized water. In this case, the retention of BaP varied from 99.82 do 99.94%. For other compounds (excluding octylphenol) we observed an inverse trend, higher retention degrees were obtained when the synthetic or real effluent were filtered. Studies documented a complex mechanism of separation of low molecular weight organic micropollutants in nanofiltration, which could be a result of intermolecular interactions, sieve effect and adsorption.
Źródło:
Proceedings of ECOpole; 2016, 10, 1; 155-164
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Inorganic Compounds on the Process of Photocatalysis of Biologically Active Compounds
Autorzy:
Kudlek, E.
Dudziak, M.
Bohdziewicz, J.
Kamińska, G.
Powiązania:
https://bibliotekanauki.pl/articles/124427.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water environment
organic micropollutants
photocatalysis
cations
anions
Opis:
Constant increase in concentration of organic micropollutants in the water environment influences the development of methods for their effective elimination from various matrices released into aquatic ecosystems. One of widely described in literature processes for the decomposition of hardly-biodegradable pollutants is the process of heterogeneous photocatalysis. The paper presents the influence of inorganic substances on the decomposition of polycyclic aromatic hydrocarbons (anthracene and benzo[a]pyrene), industrial admixtures – octylphenol and pharmaceutical compounds – diclofenac in the photocatalysis process conducted in the presence of TiO2. It has been shown that the presence of Cl ions did not affect the photochemical reaction of the micropollutant decomposition. Whereas, the presence of CO32–, SO42– and HPO42– ions inhibited the decolonization of octylphenol and diclofenac, while the degradation efficiency of anthracene and benzo[a]pyrene was reduced only by the presence of CO32– and HCO3 anions. The photooxidation of micropollutants in solutions containing Al3+ oraz Fe3+ cations proceeded with a much lower efficiency than that for solution without inorganic compounds. The analysis of the kinetics of the photocatalytic decomposition of selected micropollutants show a decrease in the reaction rate constant and an increase in their half-life due to the blocking of theactive semiconductor centers by inorganic compounds. In addition,the toxicological analysis inducated the generation of micropollutant oxidation by-products, which aggravate the quality of treated aqueous solutions.
Źródło:
Journal of Ecological Engineering; 2017, 18, 4; 123-129
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oznaczanie wybranych niesteroidowych leków przeciwbólowych i przeciwzapalnych w środowisku wodnym
Determination of selected nonsteroidal anti-inflammatory drugs in the aquatic environment
Autorzy:
Kudlek, E.
Bohdziewicz, J.
Dudziak, M.
Grübel, K.
Powiązania:
https://bibliotekanauki.pl/articles/960235.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
diklofenak
ibuprofen
ekstrakcja SPE
GC-MS (EI)
diclofenac
SPE
Opis:
Obecność związków farmaceutycznych w środowisku wodnym wymusza opracowanie skutecznej metody ich monitoringu. W pracy przedstawiono opracowany sposób oznaczenia wybranych związków farmaceutycznych z grupy niesteroidowych leków przeciwbólowych i przeciwzapalnych, tj. ibuprofenu i diklofenaku. Do wydzielenia analitów zastosowano ekstrakcję do fazy stałej (SPE), a do analizy jakościowo-ilościową chromatografię gazową sprzężoną z detektorem masowym (GC-MS). Opracowana procedura analityczna umożliwia rozdział i oznaczenie ilościowe mieszaniny związków farmaceutycznych z zadowalającą powtarzalnością i dokładnością. Wyznaczone wartości stopni odzysku dają możliwość pełnej kontroli ilościowego oznaczenia badanych farmaceutyków w próbkach wodnych. Powyższa metoda może znaleźć zastosowanie do kontroli analitycznej przebiegu procesów uzdatniania wód naturalnych i doczyszczania ścieków pod kątem eliminacji związków farmaceutycznych.
The presence of pharmaceutical compounds in the aquatic environment requires the development of an effective monitoring method. The paper presents the developed procedure of determination of pharmaceutical compounds selected from the group of nonsteroidal anti-inflammatory drugs - ibuprofen and diclofenac. To isolate selected compounds from the tested water the solid phase extraction (SPE) was employed. The quantitative and qualitative analysis was carried out by gas chromatography coupled with mass spectrometry (GC-MS). Described analytical procedure allows to separate and quantificat pharmaceutical mixtures with a satisfactory reproducibility and accuracy. The values of the recovery degree confer the possibility of the complete quantitative control of tested pharmaceuticals in water samples. The described method can be used to control the analytical processes of natural water purification and wastewater treatment from pharmaceutical compounds.
Źródło:
Proceedings of ECOpole; 2015, 9, 2; 641-648
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Toksykologiczna ocena procesu fotolitycznego oczyszczania strumieni wodnych zawierających wybrane substancje priorytetowe oraz związki farmaceutyczne
Toxicological evaluation of treatment process of water streams containing selected priority substances and pharmaceutical compounds
Autorzy:
Bohdziewicz, J.
Dudziak, M.
Kudlek, E.
Kamińska, G.
Powiązania:
https://bibliotekanauki.pl/articles/2073077.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
mikrozanieczyszczenia organiczne
fotoliza
test Microtox
organic micropollutants
photolysis
Microtox test
Opis:
W pracy zaproponowano zastosowanie testu Microtox® do oceny toksykologicznej wody zawierającej wybrane substancje priorytetowe i związki farmaceutyczne, poddanej procesowi fotolizy. Wykazano, że w trakcie napromieniowania UV dochodzi do generowania toksycznych ubocznych produktów rozkładu związków pogarszających jakość oczyszczanej wody. Ponadto stwierdzono, że stopień rozkładu badanych mikrozanieczyszczeń w procesie fotolizy zależał od rodzaju związku i czasu naświetlania.
The use of the Microtox® test for toxicological evaluation of water samples containing selected priority substances and pharmaceutical compounds subjected to the photolysis process is proposed in the paper. The results indicated that during UV irradiation toxic byproducts of their reduction were generated. Those products deteriorated the quality of treated water. It was also found that a degree of removal of tested compounds depended on the compound nature and time of UV irradiation.
Źródło:
Inżynieria i Aparatura Chemiczna; 2015, 3; 67--68
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effectivness of Removal of Selected Biologically Active Micropollutants in Nanofiltration
Ocena skuteczności usuwania wybranych substancji aktywnych biologicznie w procesie nanofiltracji
Autorzy:
Kamińska, G.
Dudziak, M.
Bohdziewicz, J.
Kudlek, E.
Powiązania:
https://bibliotekanauki.pl/articles/389054.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
biologically active compounds
nanofiltration
związki aktywne biologicznie
nanofiltracja
Opis:
This study addressed the removal efficiency of five different compounds classified as biologically active compounds ie benzo(a)pyrene (BaP), anthracene (ANT), diclofenac (DCL), pentachlorophenol (PCP), octylphenol (OP) in nanofiltration. They were removed from deionized water solution (500 µg/dm3) and comparatively from synthetic and municipal effluent. It was found that the efficiency of the nanofiltration depends on significantly both on type of membrane and the environmental matrix and physic-chemical properties of the compounds contained in the treated feed. The highest retention was observed for benzo(a)pyrene removed from deionized water. In this case, the retention of BaP varied from 99.82% to 99.94%. For other compounds (excluding octylphenol) we observed an inverse trend, higher retention degrees were obtained when the synthetic or real effluent were filtered. This study documented a complex mechanism of separation of low molecular weight organic micropollutants in nanofiltration, which could be a result of intermolecular interactions, sieve effect and adsorption. In addition, in the last part we compare our experimental data with predicted retention coefficients, which were computed from models for predicting retention of micropollutants in nanofiltration.
W ramach pracy podjęto badania nad oceną skuteczności usuwania pięciu różnych związków nale żących do grupy substancji aktywnych biologicznie, tj. benzo(a)piren (BaP), antracen (ANT), diklofenak Effectivness of Removal of Selected Biologically Active Micropollutants in Nanofiltration 197 (DCL), pentachlorofenol (PCP) i oktylofenol (OP) w procesie nanofiltracji. Przedmiotem badań były modelowe roztwory tych substancji o stężeniu 500 µg/dm3 wykonane na bazie wody zdejonizowanej. Uzyskane wyniki badań porównano pod kątem skuteczności usuwania wybranych związków z syntetycznych i rzeczywistych odpływów z komunalnej oczyszczalni ścieków. Wykazano, że na skuteczność procesu nanofiltracji istotny wpływ ma rodzaj membrany nanofiltracyjnej, właściwości fizykochemiczne usuwanych związków, jak również rodzaj matrycy środowiskowej poddawanej oczyszczaniu. Najwyższą efektywność usuwania zaobserwowano dla benzopirenu w trakcie nanofiltracji wody zdejonizowanej. Współczynniki retencji wynosiły wówczas od 99,82% do 99,94%, co oznacza praktycznie jego całkowite usunięcie. Z kolei dla pozostałych związków z wyjątkiem oktylofenolu zaobserwowano odwrotną tendencję, wyższe współczynniki retencji uzyskano, gdy filtrowanym medium były ścieki syntetyczne lub rzeczywiste. Przeprowadzone badania udokumentowa ły złożony mechanizm separacji małocząsteczkowych mikrozanieczyszczeń organicznych w procesie nanofiltracji wynikający m.in. z oddziaływań międzycząsteczkowych, efektu sitowego, jak i adsorpcji. Dodatkowo, w ostatniej części pracy porównano uzyskane dane doświadczalne z przewidywanymi współczynnikami retencji, które zostały obliczone z modeli dotyczących przewidywania retencji mikrozanieczyszczeń w procesie nanofiltracji.
Źródło:
Ecological Chemistry and Engineering. A; 2016, 23, 2; 185-198
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies