Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Seals" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Calculations of labyrinth seals with and without diagnostic extraction in fluid-flow machines
Autorzy:
Kaszowski, P.
Dzida, M.
Krzyślak, P.
Powiązania:
https://bibliotekanauki.pl/articles/259462.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
labyrinth seals
Fanno curve
diagnostic extraction
Opis:
Labyrinth seals are essential components of steam turbine unit constructions. Two types of labyrinth seals can be named, the first of which is the seal without diagnostic steam extraction, and the second – with extraction. The distribution of flow parameters along the packing is affected remarkably by the average seal clearance. The presence of diagnostic extraction leads to the equation system which is determinable and can be inversed to calculate the average seal clearance Si. Analysing the obtained results leads to the conclusion that the information about this parameter provides opportunities to monitor the current state of the packing in real time. The applied calculation procedure bases on the de Saint - Venant equation. The article also includes a brief description of both types of seals.
Źródło:
Polish Maritime Research; 2013, 4; 34-38
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analysis of the calculation process related to labyrinth sealing with extraction
Autorzy:
Joachimiak, D.
Joachimiak, M.
Krzyślak, P.
Powiązania:
https://bibliotekanauki.pl/articles/955282.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
maszyna wirnikowa
maszyna przepływowa
uszczelnienie
labyrinth seals
turbomachines
fluid-flow machines
method of calculation labyrinth seals
Opis:
The work presents a calculation process enabling one-dimensional numerical calculations of labyrinth sealing. A DSV program determines the thermodynamic parameters of gas in the sealing chambers with extraction. The influence of the sealing length upon the stability of a matrix solution of the system of equations with the use of Cond(C) parameter is analysed. Next, the operation of the software extended with a module that enables determination of the initial pressure p0, to which the assumed mass flow for a set geometry and sealing length would correspond is discussed. The work analyzes Cond(C) and initial pressure values for various sealing lengths with an assumed leak value. The work also compares the values of static pressures on the extraction plane, as obtained from the measurements, to theoretically calculated values. The calculations and comparisons were made for various heights of incomplete sealing fissures.
Źródło:
International Journal of Applied Mechanics and Engineering; 2013, 18, 4; 1057-1066
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental research and CFD calculations based investigations into gas flow in a short segment of a heavily worn straight through labyrinth seal
Autorzy:
Joachimiak, D.
Krzyślak, P.
Powiązania:
https://bibliotekanauki.pl/articles/258744.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
labyrinth seals
turbomachines
fluid-flow machines
experiment
CFD
gas velocity
Opis:
Steam turbines are used as propulsion components in not only power plants but also on merchant and naval ships. The geometry of the steam turbine seals changes throughout the machine life cycle. The rate of deterioration of these seals, in turn, affects heavily the efficiency of the thermal machine. However, the literature overview does not provide any research reports on flow phenomena occurring in heavily deteriorated seals. The paper describes the course and results of investigations into a model straight through labyrinth seal composed of 4 discs, each with the slot height of 2 mm. The investigations have been conducted with air as the working medium. Changes of gas flow parameters due to wear were analysed. Based on the experimental data, more intensive leakage was observed as the result of the increased slot height. The static pressure distribution along the examined segment was measured. The experimentally recorded distribution differed remarkably from the theoretical assumptions. Another part of the experimental research focused on comparing the gas velocities at points situated upstream of the first and second seal disc. The velocity measurements were carried out using a constant temperature wire probe. This part of the investigations provided opportunities for analysing the influence of seal wear on gas flow conditions in the seal segment. The paper compares the results of the experimental research with those obtained using the CFX software. The presented results of velocity distributions provide a clear picture of the nature of the gas flow in the seal, which enables its analysis.
Źródło:
Polish Maritime Research; 2017, 2; 83-88
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of results of experimental research with numerical calculations of a model one-sided seal
Autorzy:
Joachimiak, D.
Krzyślak, P.
Powiązania:
https://bibliotekanauki.pl/articles/239985.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
labyrinth seals
turbomachines
fluid-flow machines
uszczelnienia labiryntowe
maszyny wirnikowe
maszyny przepływowe
Opis:
Paper presents the results of experimental and numerical research of a model segment of a labyrinth seal for a different wear level. The analysis covers the extent of leakage and distribution of static pressure in the seal chambers and the planes upstream and downstream of the segment. The measurement data have been compared with the results of numerical calculations obtained using commercial software. Based on the flow conditions occurring in the area subjected to calculations, the size of the mesh defined by parameter y+ has been analyzed and the selection of the turbulence model has been described. The numerical calculations were based on the measurable thermodynamic parameters in the seal segments of steam turbines. The work contains a comparison of the mass flow and distribution of static pressure in the seal chambers obtained during the measurement and calculated numerically in a model segment of the seal of different level of wear.
Źródło:
Archives of Thermodynamics; 2015, 36, 2; 61-74
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A model of gas flow with friction in a slotted seal
Autorzy:
Joachimiak, D.
Krzyślak, P.
Powiązania:
https://bibliotekanauki.pl/articles/239930.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
slotted seals
annular slot
friction coefficient
gas flow
uszczelki szczelinowe
szczelina pierścieniowa
współczynnik tarcia
przepływ gazu
Opis:
The paper discusses thermodynamic phenomena accompanying the flow of gas in a slotted seal. The analysis of the gas flow has been described based on an irreversible adiabatic transformation. A model based on the equation of total enthalpy balance has been proposed. The iterative process of the model aims at obtaining such a gas temperature distribution that will fulfill the continuity equation. The model allows for dissipation of the kinetic energy into friction heat by making use of the Blasius equation to determine the friction coefficient. Within the works, experimental research has been performed of the gas flow in a slotted seal of slot height 2 mm. Based on the experimental data, the equation of local friction coefficient was modified with a correction parameter. This parameter was described with the function of pressure ratio to obtain a mass flow of the value from the experiment. The reason for taking up of this problem is the absence of high accuracy models for calculating the gas flow in slotted seals. The proposed model allows an accurate determination of the mass flow in a slotted seal based on the geometry and gas initial and final parameters.
Źródło:
Archives of Thermodynamics; 2016, 37, 3; 95-108
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies